2
Content
Product Feature ....................................................................1
Content .................................................................................2
Safety Precautions ...............................................................3
Application guidelines ...........................................................6
Product installation ...............................................................7
Name of parts .....................................................................11
Application method ..............................................................12
Alarm ...................................................................................15
Cleaning maintenance .........................................................16
FAQ .....................................................................................17
Refrigeration Schematic & Circuit Diagram .........................19
Circuit Diagram ....................................................................21
Specifi cation ........................................................................22
23
Specifi cation
Name
Deep Freezer
Model
DW-40W100J
DW-40W255J
DW-40W380J
Exterior dimensions
(W × D × H) (mm)
790×770×950
1210×770×950
1655×770×950
Interior dimensions
(W × D × H) (mm)
580×445×620
1000×445×620
1450×445×620
Effective volume(L)
100
255
380
Door
Foaming door
Insulation
CFC-Free foamed-in-place urethane
Compressor
High Quality Hermetically sealed compressor
Basket / loading of each
1 / max:10kg
2 / max:10kg
6 / max:10kg
Refrigeration
Direct cooling
Exterior / Interior
Spraying steel plate / Stainless steel
Condenser/Evaporator
Wire and tube type / coil tube type
Temperature control
Microprocessor controlled
Refrigerant
R290 45g
R290 55g
R290 65g
Weight(kg)
52
76
90
Temperature range
-20
℃
~-40
℃
Voltage
220-240V~/50Hz
Rated power/current(W)
260
370
450
Noise Level(dB(A))
42
42
42
Foaming Agent
CP/IP
Climate Type
4
Type of protection against electric
shock
I
Test hole
1
Alarms
Overtemperature alarm, sensor error alarm, power failure alarm
Duration time of power outage
alarm
24 hours (when battery is fully charged)
Note: Climate Type 4 means the temperature is +30
℃
,the relative humidity is 55%.Technical
information may vary from the appliance that you have just purchased due to technical improvements.