Temperature Controller Parameters
Symbol
Symbol Name
Unit
Set Value
DW-40W100/255/380
DW-25W198/300/388/518
Set
Temperature
℃
/
℉
-30 -20
PS Password
—— 22
22
/ Sensor
Parameters
/C
Temperature
Calibration for the
Environmental
Sensor
℃
/
℉
0 0
/2
Stability
Measurement
----
4 4
/4
Sensor Probe
Setup
—— 0
0
/5
Choose
℃
/
℉
(0=
℃
1=
℉
)
—— 0
0
/6
Decimal Point
Forbidden
—— 1
1
r Control
Parameters
r1
Permitted Minimum
Temperature Set
Value
℃
/
℉
-40 -30
r2
Permitted
Maximum
Temperature Set
Value
℃
/
℉
-20 -10
rd
Control Thermal
Difference
℃
/
℉
2 2
A Alarm
Parameters
A0
Alarm & Blower
Control Difference
℃
/
℉
0 0
Ad
Lag Time of
Temperature Alarm
Min. 0
0
AL
Offset of Low
Temperature Alarm
Limit Value to the
Set Value
℃
/
℉
5 5
AH
Offset of High
Temperature Alarm
Limit Value to the
Set Value
℃
/
℉
5 5
c
Compressor
Parameters
c0
Compressor Lag Time at Startup
Min. 0
0