background image

Use

Use

Use

Use

Caution

The freezer should be in the charge of a specially assigned person. He/she checks

and records the freezer’s running condition (every 2-4 hours). And, in case of a fault

or power failure, the temperature inside the freezer will rise. If the fault cannot be

cleared in a short time, please take out all articles stored in the freezer and put them

in another freezer meeting their temperature requirement to avoid deterioration.

Before putting articles to be stored in the freezer, make sure that the freezer’s

temperature range meets the temperature requirement of these articles. Otherwise

they may deteriorate because the freezer cannot reach the required temperature,

resulting in loss.

Due to the inertia of refrigeration, there is a certain difference between actually

displayed temperature and set temperature (the lower set temperature, the less

temperature difference and vice versa). It is normal.

Prohibition

All low-temperature freezers are storage equipment. It is strictly prohibited to put

too many relatively hot items in the freezer at a time; otherwise the compressor will

keep working for a long time without stop and be damaged easily and the

temperature will not reduce. Be sure to put articles in batches and make the

temperature inside the freezer reduce in steps to the desired temperature.

Do not accelerate defrosting by using any tool or method not approved by the

freezer’s manufacturer.

Do not damage the refrigerating loop.

Dot use any appliance not approved by the freezer’s manufacturer in the freezer.

Operation after power failure
The freezer can memorize the settings. In case of power failure, the freezer will still
operate with the parameters set before power failure when power supply resumes.

Temperature

Temperature

Temperature

Temperature adjustment

adjustment

adjustment

adjustment and

and

and

and setting

setting

setting

setting

The freezer’s temperature is set and

adjusted as follows:
1.

Unlocking
When the “Lock” indicator lights up, all keys except the “

” key are locked.

Press and hold the “

” key for 5s, the display area for internal temperature will

show F0 and “0” will flash; then press the “ ” key, the display area for internal
temperature will show F1; finally press the “Set” key, the keyboard will unlock
and the display panel will show internal temperature. If any key is pressed in 10s,
the keyboard will automatically be locked.

2.

Temperature setting
In initial power-on state, press the “Set” key, the display screen will show L0 and
“0” will flash; press this key again, the display screen will show the default
temperature setting (i.e. -30

) and the second digit will flash. (If the freezer is

not used for the first time, the display screen will show the temperature set last
time) Adjust the freezer to the desired temperature by pressing the “

” key to

switch the flashing digit and pressing the “ ” key to change the value of current
flashing digit, and then press the “Set” key to confirm and memorize the
temperature setting. Temperature setting range: (-20

~-45

)

3.

High temperature alarm setting
After unlocking, press the “Set” key, the display screen will show L0 and “0”
will flash; press the “ ” key, the display screen will show L1; press the “Set” key
again, the display screen will show the default temperature setting for high
temperature alarm with the second digit flashing (the default temperature setting
for high temperature alarm is internal temperature s10. Note: When
showing the temperature, the “

” sign followed by digits means the “+” sign)

and then adjust the temperature setting by pressing the “

” key to switch the

flashing digit and pressing the “ ” key to change the value and sign of current
flashing digit; after finishing setting, press the “Set” key to memorize the setting.
Temperature setting range for high temperature alarm: maximum displayed
temperature ≥ set temperature for high temperature alarm - set temperature ≥5

;

otherwise use the default setting.

4.

Low temperature alarm setting
After unlocking, the display screen will show L0 and “0” will flash. Press the
“ ” key twice, the display screen will show flashing L2; press the “Set” key, the
display screen will show the default temperature setting for low temperature
alarm with the second digit flashing (the default temperature setting for low
temperature alarm is internal temperature setting -10), and then adjust the
temperature setting by pressing the “

” key to switch the flashing digit and

pressing the “ ” key to change the value of current flashing digit; after finishing
setting, press the “Set” key to memorize the setting. Temperature setting range
for low temperature alarm: minimum displayed temperature ≤ set temperature for
low temperature alarm - set temperature ≤-5

; otherwise use the default setting.

Summary of Contents for DW-40L508

Page 1: ...tration No No 2580116 in 2008 approved by Shandong Food and Drug Administration for manufacturing medical devices updated This series of freezers is in conformity with the registration standard YZB Lu 0174 2009 Medical Medical Medical Medical Low Temperature Low Temperature Low Temperature Low Temperature Freezer Freezer Freezer Freezer Operating Operating Operating Operating Instructions Instruct...

Page 2: ...re those articles with strict temperature requirements such as living creatures and flowers etc We hereby promise to provide a complete set of 1 5 value added services for you when you require installation or maintenance service for any Haier product 1 it means installation service will be done well only once 5 it means 5 combined services a Safety test service we will perform safety test in elect...

Page 3: ...ion and warning signs are as follows The contents marked with this caution sign involve safety of both the product and user and must be strictly followed The contents marked with this prohibition sign describe absolutely prohibitory behaviors and must be strictly followed otherwise the freezer may be damaged or the user may be injured This sign is marked on the covers of high voltage electric appl...

Page 4: ...autions precautions If poisonous harmful or radioactive substances are stored in it please use the freezer in a safe area Improper use may be harmful to health or environment In case of leakage of inflammable gas such as coal gas please close the valve involved in gas leakage open windows for exhaust ventilation and do not plug in or unplug the freezer Be sure to disconnect the freezer from its po...

Page 5: ...l temperature has been low enough before putting articles in the freezer and the articles are put in the freezer in batches to prevent temperature rise The displayed temperature of low temperature freezer means the temperature at the temperature sensing probe in the preservation compartment Sometimes it is different from actual temperature in the center of preservation compartment but it will be g...

Page 6: ... using a voltage stabilizer of 3kw and above in those areas with unstable voltage to ensure normal input voltage within 220V 10 9 The freezer must be grounded reliably 10 If the power socket is equipped with ground wire please check it for reliable grounding before use If the power socket is not equipped with ground wire be sure to ask a qualified technician to install proper ground wire Use Use U...

Page 7: ...d will unlock and the display panel will show internal temperature If any key is pressed in 10s the keyboard will automatically be locked 2 Temperature setting In initial power on state press the Set key the display screen will show L0 and 0 will flash press this key again the display screen will show the default temperature setting i e 30 and the second digit will flash If the freezer is not used...

Page 8: ...ature sensor at fault E0 The indicator flashes Low battery charge level Insufficient battery charge or the battery switch is not on E5 The indicator flashes 3 times Note If several alarms sound simultaneously each fault code displays 3s Display Display Display Display and and and and alarm alarm alarm alarm Note Always turn on the battery switch before starting the freezer The freezer will enter n...

Page 9: ...t function on Page 12 for the test method In case of low battery charge level make sure that the battery switch is on and the battery is charged When the battery has been charged for consecutive 7 days please retest the battery charge level In normal conditions the battery charge should be full If low battery charge level remains it is recommended to replace the rechargeable battery The battery wi...

Page 10: ...o the battery s positive pole and the blue wire to the battery s negative pole Do not misconnect otherwise the charging circuit of computer board would be burned out easily and the battery cannot be charged Specifications Specifications Specifications Specifications Technical data Model Ambi ent tempe rature Classif ication of electric shock proof protect ion Tempe rature range Effe ctive volu me ...

Page 11: ...ng running running running In order to operate and use the recorder correctly please operate as follows 1 You will see the recorder upon opening its door 2 Switch on the backup power supply i e 9V DC battery in the upper left corner of recorder 3 Change a piece of new recording paper see the figure below 4 Remove the plastic cap from the recording pen and close the recorder s door Note The recorde...

Page 12: ...ust adjust adjust it it it it except except except except for for for for special special special special cases cases cases cases After sales After sales After sales After sales service service service service The freezer is guaranteed for free by our company for one 1 year calculated from the date of purchase the invoice shall prevail Main components including compressor condenser evaporator main...

Reviews: