1.
Remove the backup battery (9V DC), if the LED goes out and the recorder stops working, it
means that the recorder’s main power supply goes wrong. In this case, please check for power
failure, short circuit and loose connecting wire, etc. If the main power supply is in good
condition after repair, the recorder will work normally. Then install the backup battery in place,
if the LED stops flashing, it means that the backup battery is normal; if the LED goes on
flashing, it means that the backup battery is at low charge level and needs replacement until
the green LED lights up and does not flash.
2.
Remove the backup battery, if the LED goes on flashing and the recorder works normally, it
means that the main power supply is normal and the backup battery is at low charge level and
needs replacement until the green LED lights up and does not flash.
Change
Change
Change
Change of
of
of
of recording
recording
recording
recording paper
paper
paper
paper
Change the recording paper as follows:
1.
Find out the “Press” button (3#) in the upper left corner on the recorder’s front panel.
2.
Press and hold this button (3#) for about 1s until the recording pen starts moving towards the
left of recording paper.
3.
When the recording pen entirely moves out of the recording paper, loosen the center bolt and
change the used recording paper with a piece of new recording paper by carefully aligning the
time line on the paper with the time slot on the panel (there is a small slot on the left of panel.
Please see the attached figure).
4.
Retighten the center bolt, then press and hold the button (3#) to make the recording pen reset
and start recording temperature.
5.
Check whether the recording pen writes well on the paper or not. If not, you may adjust its
beam to make the penpoint contact with the recording paper.
(Note: Do not damage the
penpoint and beam. If it is difficult to adjust, you may remove the beam with a screwdriver,
bend it with a little force and reinstall it in place by repeating the above operations).
6.
To ensure the recorder’s accurate recording, please calibrate the recording pen after each paper
change as follows: press and hold the button (3#) until the recording pen moves out of the
recording paper, then press and hold the button (3#) again until the recording pen return to the
recording paper, at which time the pen will pause at the outmost temperature graduation mark
on the recording paper (this graduation mark is not necessarily with temperature value, but it
must be the outmost graduation mark). If the pen does not pause in this position, you may
adjust its position by using 1# or 2# arrow within 5s to make the penpoint align with the
outmost graduation mark. If you don’t finishing the adjustment of pen within 5s, please repeat
step 6.
Calibration
Calibration
Calibration
Calibration and
and
and
and adjustment
adjustment
adjustment
adjustment of
of
of
of the
the
the
the recorder
recorder
recorder
recorder
The recorder has been accurately adjusted before leaving the factory and will not be affected even if
power interruption. If it indeed needs adjustment, please do as follows:
1.
Keep the freezer operating continuously and then make it record the temperature curve for at least
2h after it enters stable state (the fluctuation of displayed temperature is relatively regular).
2.
Put a standard thermocouple in a bottle with about 100ml of 10% glycerite, and then put the
bottle and the recorder’s sensor together in the freezer (the recorder’s sensor must not be
contact with any solution).
3.
The glycerite bottle with thermocouple is stored in the freezer for about 4h. When the
temperature of glycerite in the bottle is identical with the freezer’s internal temperature,
compare temperature values of the standard thermocouple and recorder, if they are not the
same, you may adjust the recorder’s recorded value by using the adjusting buttons on the left
(1#) or right (2#) of panel to make it in conformity with the thermocouple’s indicated value.
Note: The recording pen starts moving 5s after the button is released.
Note:
Note:
Note:
Note: The
The
The
The recorder
recorder
recorder
recorder has
has
has
has already
already
already
already been
been
been
been calibrated
calibrated
calibrated
calibrated before
before
before
before leaving
leaving
leaving
leaving the
the
the
the factory;
factory;
factory;
factory; do
do
do
do not
not
not
not adjust
adjust
adjust
adjust it
it
it
it except
except
except
except
for
for
for
for special
special
special
special cases.
cases.
cases.
cases.
After-sales
After-sales
After-sales
After-sales service
service
service
service
The freezer is guaranteed for free by our company for one (1) year calculated from the date of
purchase (the invoice shall prevail). Main components (including compressor, condenser, evaporator,
main control panel and display panel) are guaranteed for free by our company for three (3) years.
Warranty card: when you need common consultation or repair, please contact our local
after-sales service center with both warranty card and purchase invoice on hand and keep the
warranty card properly.
Beware
of
electric
shock!
There
are
such
components
as
control
board
and
contactor,
etc.
in
the
electric
cabinet.
Label for protection against electric shock:
Warn the user not to open the electric
cabinet
at random.
Before power-on, please turn on the
battery switch on the electric cabinet at
the back of freezer. If the freezer is to
be left unused for a long time, please
power off first, and then turn off the
battery switch.
Label for the use of rechargeable battery:
Describe the precautions for the use of
rechargeable
battery
Rechargeable battery switch
Label for the rechargeable battery switch:
Show the position of rechargeable battery
switch
Grounding sign
Label for operation instructions and
precautions:
Instruct the user in operation and relevant
precautions
Operation Steps and Precautions for the Low-temperature Freezer
Unlocking
When the “Lock” indicator lights up, all keys except the “
” key are
locked. Press and hold the “
” key for 5s, the display area for internal
temperature will show F0 and “0” will flash; then press the “
” key, the
display area for internal temperature will show F1; finally press the “Set”
key, the keyboard will unlock.
Temperature setting
In the unlocked state, press the “Set” key, the display screen will show L0
and “0” will flash; press this key again, the display screen will show the
former temperature setting with the second digit flashing. Adjust the
freezer to the desired temperature by pressing the “
” key to switch
the flashing digit and pressing the “
” key to change the value of current
flashing digit, and then press the “Set” key to confirm and memorize the
temperature setting. Temperature setting range: (-20
℃
~-40
℃
)
Precautions
1.
After initial installation or movement, please adjust the legs and
make them rest on the floor to make sure that the freezer will not move
during use, then leave the freezer still for at least 24h before turning it on.
2.
When
using
the
freezer,
maximumly
control
the
room
temperature below 28
℃
(If ambient temperature is above 32
℃
, the
cooling efficiency will reduce rapidly. Also, if ambient temperature is
above 32
℃
for a long time, the compressor will be damaged or its
service life will reduce. In this case, it is recommended to install an air
conditioner).
3.
The freezer should use an independent power socket of the
carrying current above 16A and reliable grounding.
4.
Before power-on, please turn on the battery switch on the electric
cabinet at the back of freezer. If the freezer is to be left unused for a long
time, please power off first, and then turn off the battery switch.
5.
Maximumly control the time of each opening within 1min, and
wipe off all ice and water on the door seal before closing the freezer’s
doors to ensure high sealing performance.
6.
To extend the freezer’s service
life and reduce energy
consumption, it is recommended to set the temperature in the range of -20
℃
~-40
℃
on the premise that the safety of items in the freezer is
guaranteed.
7.
The freezer is used for the storage of items at low temperature
and not used for quick freezing. It must not be forced to quickly freeze a
large quantity of hot products or large-volume liquid products.
8.
If the freezer does not refrigerate in 2-3 hours after power on,
please unplug it and contact our after-sales service enter as soon as
possible.
9.
In case of alarm or any other fault, please clear the fault
according to the prompts on the display panel. If there is no prompt or
you cannot clear the fault, please do not disassemble the freezer by
yourself but immediately contact our after-sales service center to ask a
qualified maintainer for fault clearance.
Fault codes are as follows:
High
temperature
alarm
E9
Main
sensor
fault
alarm
E6
Low
temperature
alarm
E10
Ambient temperature
sensor fault alarm
E0
Over-high ambient
temperature alarm
E14
Low battery charge
level
or
battery
switch off
E5
______Haier Group customer service hotline (for the whole