Haier BRF1- 120 User Manual Download Page 9

9

6

Installation

Installment of water-storing tank

Water storing tank equipped for water heater is a standing tank. Based on 
customers' requests, ensure specific installment position, and place water-
storing tank. Connection opening of water-storing tank faces one side of the 
pipeline, and then all corresponding parts of each connection opening should 
be connected. Layout of water tank should be perfected in installing. 

Installment of water pump

To connect the the water inlet of pump to circulating water-exiting opening 
and the dirrection must be right.pay attention that the connection of water 
pump must be firm. Power of water pump should be adjusted to the third 
grade, and it is prohibited to put other articles on water pump.To avoid that 
water spurts out to the pump,or the result is serious.

Connection of pipeline

To measure the distance between water inlet of collector equipment and 
water pump as well as that between water-exiting of collector equipment and 
circulating entrance of water-storing tank. To cut pipes according to the 
measured size, to cover the heat preservation layer, and to connect collector 
equipment, water pump and water-storing tank. Pay attention that the 
connection of circulating pipeline should avoid the opposite alternative. The 
connection of pipe parts should be proper and firm, and the heat preservation 
materials should be covered perfectly. Pay attention that the probe of the 
sensor is placed properly. Installment of pipeline should be artistic and neat.

Connection of collector equipment and water-storing tank

After the collector equipment is fixed, one end of the equipment should be 
joined to the tee joint, and the top hole of the tee joint should be connected to 
an automatic exhausting valve and the bottom hole should be connected to 
the water- exiting pipe. The Water-exiting pipe should be connected to 
circulating entrance of water-storing tank,the oherside of the collector 
equipment should be connected to circulating exit of of water-storing tank.  
Pay attention that connection of circulating pipeline is proper and firm and 
that the heat-preservation materials are covered perfectly.

Installment of other accessories 

Connection of Single direction valve

Fix the single direction valve on the 

Water-exiting pipe of the collector equipment,the direction of  the single 
direction valve and the direction of the Water-exiting pipe must keep same, 
please see Fig.1- Fig.2.
Connection and Use of Safety Valve

after switching on the water heater, a 

little water will drip from the safety valve pressure relief vent due to normal 
expansion. The vent shall always keep open to the air. Avoid being blocked.   

Ò £ ¿ Ø Æ ÷ Ê ¹ Ó Ã ¼ ò ½ é

1.Function introduction of controlling board

There are five icons on the indication screen, among which are the following four 
icons: solar energy, simultaneous heating, preset, and intellectual power. They 
respectively represent the four modes of the system working, that is solar 
energy heating mode, simultaneous heating mode, preset heating mode and 
intellectual heating mode. And the water pump icon is used to prove that water 
pump is in a condition of full speed circulated running. For the indication board, 
see Figure 5.                                                               
For details, see the following:
      ---When the green point in the icon is on, it tells that the system is in the solar 
energy heating mode.
      (Double color)---when the green point in the icon is on, it tells that the system 
is in the simultaneous heating. When the red light is glistening, it tells that the 
ystem in electrical heating and when it reaches the mounted temperature, it will 
automatically leap to the solar energy heating mode.
     (Double color)--- when the green point in the icon is on, it tells that the system 
is in the preset heating mode. When the red light is glistening, itmounted  tells 
that the system in electrical heating and when it mounted reaches the 
temperature, the green point will be on constantly.
     (Double color)--- when the green point in the icon is on, it tells that the system 
is in the intellectual heating mode. When the red light is glistening, it tells that 
the system in electrical heating and when it reaches the temperature, the green 
point will be on constantly.
     --- Arrows on the icon are in proper order with counter hour hand. When the 
green point is on, it tells that the water pump is in 100% full speed running 
condition.
    Temperature indication icon for tank--- when the character is on, it tells that 
the present indication temperature is water temperature of  the tank.
     Temperature indication icon for collector equipment--- when the character is 
on, it tells that the present indication temperature is the water-exiting 
temperature of collector equipment.

2. introduction of basic working mode

A. Solar energy heating: this function adopts the temperature difference 

between water-exiting temperature of collector equipment and that of water-
storing tank to control the running of water pump. It transfers solar energy 
absorbed by collector equipment to hot water in water-storing tank for

For the first use after installation, due to there's no water within the tank, first the 
cold water inlet valve and mixing valve must be opened. Close the mixing valve 
when water flows out continuously from the showerhead or other outlets (the 
tank is full). Check connections are free of water leakage, and insert the power 
plug. 

Use method

Summary of Contents for BRF1- 120

Page 1: ... Rev 01 specific number 0040500208 Group Qingdao Economic and Technical Development Zone Haier Water Heater Co Ltd website www haier com Solar Water Heater Sincerity For Ever Please read this manual carefully before use Please keep this manual for future reference Users Manual ...

Page 2: ...ment of products Haier water heater you purchase might not consist with the figures in the instruction for which we apologize here to you Haier Correct Disposal of this product This marking indicates that this product shoud not be disposed with other househoud wastes To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to ptomote the s...

Page 3: ...exiting is cold No temperature rising Is water supply failed or water pressure too low Is water exit blocked Is hot water valve opened Indication E3 Large amount of water flows out of safety valve Indication E4 Indication E5 Is water temperature adjusted Is temperature controller loss of control Sunshine unsufficient Is Heating element idamaged Is the tap water pressure stable Unable to turn on Wh...

Page 4: ... solar energy heating mode 4 In normal use the tap water entrance valve of water storing tank should be kept constantly open You only need to open the mixed valve to adjust water temperature when taking a bath and then you can use freely 5 Please pay attention to the temperature of water storing tank when taking a bath and avoid being scalded by too hot water or being hurt by too cold water 6 Plea...

Page 5: ...dition Preset heating mode Indicating clock condition to set hour of the first preset heating time in fixing time to set minute of the first preset heating time in fixing time to set temperature of preset heating in fixing temperature to set hour of the second preset heating time in fixing time to set minute of the second preset heating time in fixing time to set temperature of the second preset h...

Page 6: ...is turned off the solar heating and malfunction alarm protection are all working and only if the conditions for the running of the water pump are Satisfied water pump will run at full speed When malfunction alarm appears it will display malfunction code B Selection of working mode the system provides four working modes and customers can select any mode as the present working mode When the system i...

Page 7: ...ng period arrives the second day In cases when the machine is turned on press the when the machine is turned on press the mode key continually to enter intellectual heating mode The green point in the working indication icon is on When the electrical heating starts the red point in the icon glistens And when the electrical heating is over the green point is constantly on Press the setting mode and...

Page 8: ... starting conditions for water pump are reached then the water exiting temperature of collector equipment 20 Meanwhile when temperature difference between water exiting of collector and water in Water storing Tank is higher than the set value 6 or 10 water pump will start and run at full speed When the temperature difference is less than 2 water pump will automatically stop B simultaneous heating ...

Page 9: ...ef vent due to normal expansion The vent shall always keep open to the air Avoid being blocked Ò Ø Æ Ê Ó Ã ò é 1 Function introduction of controlling board There are five icons on the indication screen among which are the following four icons solar energy simultaneous heating preset and intellectual power They respectively represent the four modes of the system working that is solar energy heating...

Page 10: ...ank collector equipment and system pipeline Through cold water opening of tap water To close water exiting valve of hot water until the air is exhausted and water flows out continually Meanwhile to observe whether the system leaks and to keep the cold water entrance open in the process of use 8 Introduction of indication board 13 icon for intellectual power heating 14 upwards adjusting key 15 down...

Reviews: