13

2

System structure

press 

more than one second, the adjusted parameter will decrease 

progressively 3 numbers every second.). The adjusting clock can be set in 
clock  column, the preset time can be set in fixing time column, the heating 
temperature can be set in fixing temperature column, and the temperature 
difference can be set in temperature differencecolumn. Confirming of the 
setting of each parameter can be done by pressing the setting key or by not 
pressing the setting key about 6 seconds.Then the system will automatically 
confirm and automatically enter the next parameter setting, until the system 
finally withdraws from the set conditions and returns to the conditions of the 
previous clock. The set order of parameter in specific modes is as follows:

Solar energy heating mode:

Indicating clock condition---to set heating temperature in fixing temperature-
--indicating clock condition. For example: temperature difference value 
setting of water pump running: to press the setting key to enter the setting 
condition of temperature difference of water pump running. The indication 
board indicates the present set value (the first place on the left of the clock 
number tube indicates L, and the following two places indicate the tacitly 
approved set value, which is 10 

). To press 

V

 to select 

between 10 

 and 6

. For the indication interface, see Fig.8.

Simultaneous heating mode:

I n d i c a t i o n   c l o c k  c o n d i t i o n - - t o   s e t  h e a t i n g   t e m p e r a t u r e  i n   f i x e d 
temperatureindication clock condition

Preset heating mode: 

Indicating clock condition--to set hour of the first preset heating time in  fixing 
time 

--to set minute of the first preset heating time in fixing time

-

-to set temperature of preset heating in fixing temperature 

-- to set 

hour of the second preset heating time in fixing time

-- to set minute of 

the second preset heating time in fixing time

---to set temperature of 

the second preset heating in fixing temperature 

---indicating clock 

condition. For example: to set the temperature of the first preset heating, and 
for the indication interface,see Fig. 9.

Intellectual heating mode:

Indicating clock condition---to set temperature of heating in fixing 
temperature column--- indicating clock condition. 
Note:after the set (tacitly approved) information is confirmed, the machine 
will automatically store it and customers can select the present working mode 
according to their practical necessity. Only when the present working mode is 
selected, can the corresponding set content be carried out.

Use method

Exhaust valve

Tee joint

Metal pipe: ( copper or corrugation pipe)

Pump

Safety valve

Water-storing tank

Outdoors

Indoors

Metal or PPR pipe

Vacuum tube Collector

Line-controlling equipment

Single direction valve

Water-entering opening

Water-exiting pipe

Water-exiting opening

 

Cold water inlet

Hot water outlet

Hot water outlet

Cold water inlet

Pump

Safety valve

Water-storing tank

Outdoors

Indoors

Metal or PPR pipe

Flat collecter

Line-controlling equipment

Single direction valve

Water-exiting opening

 

Metal pipe: ( copper or corrugation pipe)

Tee joint

Water-exiting pipe

Fig.1  BRF1-120/150W  structure sketch map

Fig.2 PJF1-120/150W structure sketch map

Exhaust valve

Summary of Contents for BRF1- 120

Page 1: ... Rev 01 specific number 0040500208 Group Qingdao Economic and Technical Development Zone Haier Water Heater Co Ltd website www haier com Solar Water Heater Sincerity For Ever Please read this manual carefully before use Please keep this manual for future reference Users Manual ...

Page 2: ...ment of products Haier water heater you purchase might not consist with the figures in the instruction for which we apologize here to you Haier Correct Disposal of this product This marking indicates that this product shoud not be disposed with other househoud wastes To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to ptomote the s...

Page 3: ...exiting is cold No temperature rising Is water supply failed or water pressure too low Is water exit blocked Is hot water valve opened Indication E3 Large amount of water flows out of safety valve Indication E4 Indication E5 Is water temperature adjusted Is temperature controller loss of control Sunshine unsufficient Is Heating element idamaged Is the tap water pressure stable Unable to turn on Wh...

Page 4: ... solar energy heating mode 4 In normal use the tap water entrance valve of water storing tank should be kept constantly open You only need to open the mixed valve to adjust water temperature when taking a bath and then you can use freely 5 Please pay attention to the temperature of water storing tank when taking a bath and avoid being scalded by too hot water or being hurt by too cold water 6 Plea...

Page 5: ...dition Preset heating mode Indicating clock condition to set hour of the first preset heating time in fixing time to set minute of the first preset heating time in fixing time to set temperature of preset heating in fixing temperature to set hour of the second preset heating time in fixing time to set minute of the second preset heating time in fixing time to set temperature of the second preset h...

Page 6: ...is turned off the solar heating and malfunction alarm protection are all working and only if the conditions for the running of the water pump are Satisfied water pump will run at full speed When malfunction alarm appears it will display malfunction code B Selection of working mode the system provides four working modes and customers can select any mode as the present working mode When the system i...

Page 7: ...ng period arrives the second day In cases when the machine is turned on press the when the machine is turned on press the mode key continually to enter intellectual heating mode The green point in the working indication icon is on When the electrical heating starts the red point in the icon glistens And when the electrical heating is over the green point is constantly on Press the setting mode and...

Page 8: ... starting conditions for water pump are reached then the water exiting temperature of collector equipment 20 Meanwhile when temperature difference between water exiting of collector and water in Water storing Tank is higher than the set value 6 or 10 water pump will start and run at full speed When the temperature difference is less than 2 water pump will automatically stop B simultaneous heating ...

Page 9: ...ef vent due to normal expansion The vent shall always keep open to the air Avoid being blocked Ò Ø Æ Ê Ó Ã ò é 1 Function introduction of controlling board There are five icons on the indication screen among which are the following four icons solar energy simultaneous heating preset and intellectual power They respectively represent the four modes of the system working that is solar energy heating...

Page 10: ...ank collector equipment and system pipeline Through cold water opening of tap water To close water exiting valve of hot water until the air is exhausted and water flows out continually Meanwhile to observe whether the system leaks and to keep the cold water entrance open in the process of use 8 Introduction of indication board 13 icon for intellectual power heating 14 upwards adjusting key 15 down...

Reviews: