TESTING
PAGE 57
ENGLISH
SLIM DUCT TESTING PROCEDURES
Testing Communication Circuit
If an Error E7 occurs, perform the following test to determine
if the indoor control board is functioning properly to send data
to the outdoor unit.
Perform this test with the unit powered and all wiring
connected between indoor and outdoor unit.
Make sure all wiring between the indoor and outdoor unit
are correct. There should no splices between the indoor and
outdoor unit wiring connecting terminals 1 or 3. Make sure
wiring is correct, before performing this test.
1.
Measure the DC voltage between terminals 1 and 3
on the indoor terminal block.
2.
The voltage should fluctuate between 8VDC
and 23VDC. The fluctuating signal indicates a good
communication path.
3.
If the voltage does not fluctuate, and the wiring is
good, the indoor board is defective.
Summary of Contents for AW07LC2VHA
Page 3: ...PAGE 3 ENGLISH INTRODUCTION SPECIFICATIONS Multi Zone Indoor...
Page 4: ...PAGE 4 ENGLISH INTRODUCTION SPECIFICATIONS Multi Zone Indoor...
Page 5: ...PAGE 5 ENGLISH INTRODUCTION SPECIFICATIONS Multi Zone Outdoor...
Page 73: ...REFERENCES PAGE 73 ENGLISH Component Ratings REFERENCES...
Page 76: ...REFERENCES PAGE 76 ENGLISH Wiring REFERENCES...
Page 77: ...REFERENCES PAGE 77 ENGLISH Wiring REFERENCES...
Page 78: ...REFERENCES PAGE 78 ENGLISH Wiring REFERENCES...
Page 79: ...REFERENCES PAGE 79 ENGLISH Wiring REFERENCES...
Page 80: ...REFERENCES PAGE 80 ENGLISH Wiring REFERENCES...
Page 81: ...REFERENCES PAGE 81 ENGLISH 2U Wiring REFERENCES...
Page 82: ...REFERENCES PAGE 82 ENGLISH CN20 Connector for room card Wiring REFERENCES...
Page 83: ...REFERENCES PAGE 83 ENGLISH SWI Wiring REFERENCES...
Page 84: ...REFERENCES PAGE 84 ENGLISH Wiring REFERENCES...
Page 86: ...REFERENCES PAGE 86 ENGLISH CIRCUIT DIAGRAMS REFERENCES...
Page 87: ...REFERENCES PAGE 87 ENGLISH CIRCUIT DIAGRAMS REFERENCES...
Page 88: ...REFERENCES PAGE 88 ENGLISH WIRING DIAGRAMS REFERENCES...
Page 89: ...REFERENCES PAGE 89 ENGLISH WIRING DIAGRAMS REFERENCES...
Page 90: ...REFERENCES PAGE 90 ENGLISH 2U Piping Installation Dimensions REFERENCES...
Page 92: ...REFERENCES PAGE 92 ENGLISH Refrigerant Diagram REFERENCES...
Page 93: ...REFERENCES PAGE 93 ENGLISH Refrigerant Diagram REFERENCES...
Page 94: ...REFERENCES PAGE 94 ENGLISH 3U Piping Installation Dimensions REFERENCES...
Page 95: ...REFERENCES PAGE 95 ENGLISH 4U Piping Installation Dimensions REFERENCES...
Page 110: ...REFERENCES PAGE 110 ENGLISH SENSORS Value of Thermistor Indoor Unit...
Page 111: ...REFERENCES PAGE 111 ENGLISH SENSORS...
Page 112: ...REFERENCES PAGE 112 ENGLISH SENSORS...
Page 113: ...REFERENCES PAGE 113 ENGLISH SENSORS...
Page 114: ...REFERENCES PAGE 114 ENGLISH SENSORS...
Page 115: ...REFERENCES PAGE 115 ENGLISH SENSORS...
Page 116: ...REFERENCES PAGE 116 ENGLISH SENSORS...
Page 117: ...REFERENCES PAGE 117 ENGLISH SENSORS...
Page 118: ...REFERENCES PAGE 118 ENGLISH SENSORS...
Page 119: ...REFERENCES PAGE 119 ENGLISH SENSORS...
Page 120: ...REFERENCES PAGE 120 ENGLISH SENSORS...