Service Diagnosis
44
All-in-one board
Indoor display E7 outdoor display LED2 flash 15 times
Communication is detected by checking the indoor PCB and the outdoor PCB.
The outdoor PCB broken leads to communication fault.
The indoor PCB broken leads to communication fault.
Communication wiring disconnected.
The indoor PCB is broken.
The outdoor PCB is broken.
* Caution: Be sure to turn off power switch before connect or disconnect connector,
or else parts damage may be occurred.
The outdoor PCB needs
dehumidification
Is it normal after
restart the AC?
If starting up
normally, but
malfunction occurs
again after a while
The outdoor PCB needs
dust
NO
YES
NO
YES
YES
Reconnect the
connecting
cable or replace
with a new one.
NO
Supposed
Causes
Malfunction
Decision
Conditions
Method of
Malfunction
Detection
Check whether the linking cable
between the indoor and outdoor is
well connected or whether its core
wires are well insulated or its L/N is
not reversed.
Trouble
shooting
Summary of Contents for AS35RBAHRA-PL
Page 12: ...Piping diagrams Domestic air conditioner 5 Piping diagrams 10 9 52CuT 9 52CuT 6 35CuT 6 35CuT...
Page 15: ...Printed circuit board connector wiring diagram 13 Domestic air conditioner Wiring diagrams...
Page 50: ...Circuit diagrams 49 Domestic air conditioner 11 Circuit Diagrams...
Page 51: ...Circuit diagrams 50 Domestic air conditioner...
Page 55: ...three 6 Removal Procedure 54 Domestic Air Conditioner Remove the casing 1 2 3...
Page 59: ...Removal Procedure 58 Domestic Air Conditioner motor cover motor cover...
Page 60: ...Removal Procedure 59 Domestic Air Conditioner...