Indoor Unit Installation

Fix to side bar and lintel a mounting bar, Which is separately sold, and

then

ƽ

fasten the plate to the fixed mounting bar.

Refer to the previous article, “ When the mounting plate is

ƽ

position of wall hole.

Make a hole of 70 mm in diameter, slightly descending to outside the wall.

ƽ

Install piping hole cover and seal it off with putty after installation

ƽ

1. Carry out, based on the neighboring pillars or lintels,  a 

to be fixed against the wall, then temporarily fasten the plate

with one steel nail.

2. Make sure once more the proper level of the plate, by hanging a thread

with

   a weight from the central top of the plate, then fasten securely the

plate with the attachment steel nail.

3. Find the wall hole location A using a measuring tape

When the mounting plate is fixed side bar and lintel

Fitting of the Mounting Plate and Positioning of the wall Hole

Lid for right
piping

Lid for under piping pipe

Fix with adhesive tape

Lid for left piping

Indoor/outdoor electric cable and drain hose must be bound with

efrigerant

ƽ

piping by protecting tape.

[ Other direction piping ]

Cut away, with a nipper, the lid for piping according to the piping

direction and

ƽ

then bend the pipe according to theposition of wall

hole. When bending, be careful not to crash pipes.

Connect beforehand the indoor/outdoor electric cable,

ƽ

and then

pull out the connected to the heat insulation of connecting part
specially.

proper leveling

for the plate

first fixed “,

for the

Making a Hole on the Wall and Fitting the Piping Hole Cover

Drawing of pipe

Installation of the Indoor Unit

[ Rear piping  ]

Draw pipes and the drain hose, then fasten them with the adhesive tape

ƽ

[ Left

·

Left-rear piping ]

In case of left side piping, cut away, with a nipper, the lid for left piping.

ƽ

In case of left-rear piping, bend the pipes according to the piping

direction to

ƽ

the mark of hole for left-rear piping which is marked on heat

insulation materials.

1. Insert the drain hose into the dent of heat insulation materials of 

indoor unit.

2. Insert the indoor/outdoor electric cable from backside of  indoor

unit, and pull it out on the front side, then connect them.

3. Coat the flaring seal face with refrigerant oil and connect pipes.

Cover the connection part with heat insulation materials closely,
and make sure fixing with adhesive tape

Hang surely the unit body onto the upper

notches of the

ƽ

mounting plate. Move the body

from side to side to verify its secure fixing.

In order to fix the body onto the mounting

plate,hold up

ƽ

the body aslant from the

underside and then put it down perpendicularly.

Remove terminal cover at right bottom corner of 

indoor unit, then take

ƽ

 off wiring cover by removing

its screws.

mounting plate

When you unload the indoor unit,please use your hand to arise 

slightly and lift the unit aslant until it leaves the mounting plate. 

agraffe

mounting plate

ƽ

 the body to leave agraffe,then lift the bottom of the body outward

A=145mm

30mm

B=

70mm

Ø

Heat insulation
material

Drain hose

Piping

Pipe supporting
plate

Indoor/outdoor electric cable

Indoor side

Outdoor side

Ø70mm

Wall hole

Thickness of wall

(Section of wall hole)

 Piping hole pipe

G

When the mounting plate is first fixed

Fixing the indoor unit body

Unloading of indoor unit body

Connecting the indoor/outdoor Electric Cable

Removing the wiring cover

7

A=150mm

B= 70mm

35mm

Summary of Contents for AS18GS1ERA -

Page 1: ...onditioner Keep this operation manual for future reference SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL 10 2 3 9 11 PARTS AND FUNCTIONS OPERATION MAINTENANCE TROUBLE SHOOTING CAUTIONS INDOOR UNIT INSTALLAION 5 Contents NO 0010535426 AS18GS1ERA AS24GS1ERA ...

Page 2: ...r reference Please be subject to the actual produce purchased the above picture is just from your reference Air Purifying Filter inside Inlet 1 Inlet grille 2 Outlet 3 adjust left and right air flow Vertical blade 4 Display board Horizontal flap adjust up and down air flow Don t adjust it manually Emergency Switch 6 7 8 5 1 2 3 4 5 6 7 8 11 10 8 9 13 14 15 16 12 17 ON OFF FAN MODE SWING TIMER CLOC...

Page 3: ...operation air conditioner will automatically select Cool or Heat operation according to room temperature to AUTO the air conditioner automatically adjusts temperature When FAN is set the fan speed according to room In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN mode And temp setting is disabled In FAN mode sleep operation sett...

Page 4: ...When TIMER function is set the quiet sleeping function can t be set up After the sleeping function is set up if user resets TIMER function the sleeping function will be cancelled the machine will be in the state of timing on if the two modes are set up at the same time either of their operation time is ended first the unit will stop automatically and the other mode will be cancelled When quiet sle...

Page 5: ...e the system yourself the dismantling of the air EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS 1 1 2 kg R410A 2 kg 2 1 B C D F E kg A This product contains fluorinated greenhouse gases covered by the Kyoto Protocol Do not vent into the atmosphere Refrigerant type R410A GWP value 1975 GWP global warming potential Please fill in with indelible ink 1 the factory refrigerant charge of the product 2 t...

Page 6: ...ing can be conne cted with the outdoor unit ƽ Place where cold air can be spread in a room entirely ƽ Place nearby a power receptacle with enough space around ƽ Place where the distance of more than lm from televisions radios wireless apparatuses and fluorescent lamps can be left ƽ In the case of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluore sc...

Page 7: ...ndoor Unit Rear piping Draw pipes and the drain hose then fasten them with the adhesive tape ƽ Left Left rear piping In case of left side piping cut away with a nipper the lid for left piping ƽ In case of left rear piping bend the pipes according to the piping direction to ƽ the mark of hole for left rear piping which is marked on heat insulation materials 1 Insert the drain hose into the dent of ...

Page 8: ...Flare tool for R410A Conventional flare tool Clutch type clutch type Rigid type Wing nut type Imperial type A 0 0 5mm 1 0 1 5mm 1 5 2 0mm rth leakage breaker Lean Damage of flare Partial Too outside Correct Incorrect On Drainage It becomes high midway The gap with the ground is too small There is the bad smell from a ditch It waves The end is imm ersed in water Please install the drain hose so as to...

Page 9: ...he right side of the indoor unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter The white side of the photocatalyst air purifying filter face outside and the black side face the unit The green side of the bacteria killing medium air purifying filter face out...

Page 10: ...TION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is running at t...

Page 11: ...Cautions 3 If the fuse of indoor unit on PC board is it with the type of T 3 15A 250V outdoor broken change it with the type of T 25A 250V Do not obstruct or cover the ventilation conditoner Do not put fingers inlet outlet and swing louver Do not allow children to play with the air conditioner case should children be allowed to sit on the outdoor unit The refrigerating circuit is leak proof 1 Appl...

Reviews: