background image

2

Outdoor  Unit

Loading of the battery

1

2

3

4

Parts and Functions

Indoor Unit

OUTLET

INLET

CONNECTING PIPING AND ELECTRICAL WIRING

DRAIN HOSE

Remote controller

Remove the battery cover;

Load the batteries as illustrated. 

2 R-03 batteries, resetting key 

(cylinder);

Be sure that the loading

is in line with th

e" + "/"-";

Load the battery,then put on the cover again.

Clock set

Press CLOCK button, "AM" or "PM" flashes.

Press    or    to set correct time. Each press 

change quickly. After time setting is confirmed,press SET,

"AM "and "PM" stop flashing,while clock starts working. 

 or decrease 1min. If the button is kept pressed,time will 

will increase

 The distance between the signal transmission head and the rece-
iver hole should be within 7m without any obstacle as well.

When electronic-sta rted type fluorescent lamp or change- over

wireless telephone is installed in the 

ver is apt to be disturbed in receiving the signals,

so the distance to the indoor unit should be shorter.

type fluorescent lamp or
room, the recei

Note:

Full display or unclear display during operation indicates the 

ries have been used up.Please change batteries.

If the remote controller can't run normally during operation, please 

reload several minutes later.

batte

remove the batteries and

Please be subject to the actual produce purchased the 
above picture is just from your reference

Please be subject to the actual produce purchased the 
above picture is just from your reference

Air Purifying Filter

(inside)

Inlet

1

Inlet grille

2

Outlet

3

(adjust left and right air flow) 

Vertical blade

4

 Display board

Horizontal flap

(adjust up and down air flow.

  Don't adjust it manually)

Emergency Switch

6

7

8

5

1

2

3

4

5

6

7

8

11

10

8

9

13

14
15
16

12

17

ON/OFF

FAN

MODE

SWING

TIMER

CLOCK

SET

SLEEP

LOCK

RESET

18

4

22

19

23

1

6

5

2

21

3

24

POWER/SOFT

LIGHT

20

LOCK

RESET

TIMER

CLOCK

SET

SLEEP

POWER/SOFT

LIGHT

7

9. LOCK display
10. SWING display
11. Mode display

LO

MED

HI

AUTO

POWER

SOFT

BLANK

12. TEMP display
13. SIGNAL SENDING
14. TIMER OFF display
15. TIMER ON display
16. CLOCK display
17. SLEEP display
18. POWER ON/OFF button
19. SWING button
20. HOUR / POWER/SOFT button
Used to set clock and timer setting.
Press this button at any time except
for setting the remote control time 
and setting time

display changes 

as follows: 

21. TIMER button
Used to set correct time.
22. HOUR button
23. SLEEP button
24. RESET button
When the remote controller
appears abnormal, use a sharp
pointed article to press this 
button to reset the remote
controller normal.

Operation mode

AUTO

FAN

COOL

DRY

Remote controller

HEAT

1. LOCK button
Used to lock buttons and 
LCD display.
2. SET / LIGHT button
3. CLOCK button
4. MODE button
5. TEMP.SETTING button
6. FAN button
7. HEALTH display
8. FAN SPEED display

4

Hint:
Remove the batteries in case won't be in use for a long period. If
there is any display after taking-out, just press reset key.

Summary of Contents for AS18GS1ERA -

Page 1: ...onditioner Keep this operation manual for future reference SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL 10 2 3 9 11 PARTS AND FUNCTIONS OPERATION MAINTENANCE TROUBLE SHOOTING CAUTIONS INDOOR UNIT INSTALLAION 5 Contents NO 0010535426 AS18GS1ERA AS24GS1ERA ...

Page 2: ...r reference Please be subject to the actual produce purchased the above picture is just from your reference Air Purifying Filter inside Inlet 1 Inlet grille 2 Outlet 3 adjust left and right air flow Vertical blade 4 Display board Horizontal flap adjust up and down air flow Don t adjust it manually Emergency Switch 6 7 8 5 1 2 3 4 5 6 7 8 11 10 8 9 13 14 15 16 12 17 ON OFF FAN MODE SWING TIMER CLOC...

Page 3: ...operation air conditioner will automatically select Cool or Heat operation according to room temperature to AUTO the air conditioner automatically adjusts temperature When FAN is set the fan speed according to room In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN mode And temp setting is disabled In FAN mode sleep operation sett...

Page 4: ...When TIMER function is set the quiet sleeping function can t be set up After the sleeping function is set up if user resets TIMER function the sleeping function will be cancelled the machine will be in the state of timing on if the two modes are set up at the same time either of their operation time is ended first the unit will stop automatically and the other mode will be cancelled When quiet sle...

Page 5: ...e the system yourself the dismantling of the air EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS 1 1 2 kg R410A 2 kg 2 1 B C D F E kg A This product contains fluorinated greenhouse gases covered by the Kyoto Protocol Do not vent into the atmosphere Refrigerant type R410A GWP value 1975 GWP global warming potential Please fill in with indelible ink 1 the factory refrigerant charge of the product 2 t...

Page 6: ...ing can be conne cted with the outdoor unit ƽ Place where cold air can be spread in a room entirely ƽ Place nearby a power receptacle with enough space around ƽ Place where the distance of more than lm from televisions radios wireless apparatuses and fluorescent lamps can be left ƽ In the case of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluore sc...

Page 7: ...ndoor Unit Rear piping Draw pipes and the drain hose then fasten them with the adhesive tape ƽ Left Left rear piping In case of left side piping cut away with a nipper the lid for left piping ƽ In case of left rear piping bend the pipes according to the piping direction to ƽ the mark of hole for left rear piping which is marked on heat insulation materials 1 Insert the drain hose into the dent of ...

Page 8: ...Flare tool for R410A Conventional flare tool Clutch type clutch type Rigid type Wing nut type Imperial type A 0 0 5mm 1 0 1 5mm 1 5 2 0mm rth leakage breaker Lean Damage of flare Partial Too outside Correct Incorrect On Drainage It becomes high midway The gap with the ground is too small There is the bad smell from a ditch It waves The end is imm ersed in water Please install the drain hose so as to...

Page 9: ...he right side of the indoor unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter The white side of the photocatalyst air purifying filter face outside and the black side face the unit The green side of the bacteria killing medium air purifying filter face out...

Page 10: ...TION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is running at t...

Page 11: ...Cautions 3 If the fuse of indoor unit on PC board is it with the type of T 3 15A 250V outdoor broken change it with the type of T 25A 250V Do not obstruct or cover the ventilation conditoner Do not put fingers inlet outlet and swing louver Do not allow children to play with the air conditioner case should children be allowed to sit on the outdoor unit The refrigerating circuit is leak proof 1 Appl...