Haier AS07ZS2ERA Operation Manual Download Page 12

Trouble shooting

Normal
Performance
inspection

Noise is heard

Phenomenon

Cause or check points

The system 

immediately.

Smells are

generated.

Mist or steam are 

Multiple

check

Poor cooling

When unit is stopped, it won't restart 

elapsed to protect the system.

When the electric plug is pulled out 

and reinserted, the protection circuit 

During unit operation or at stop, 

a swishing or gurgling noise may 

(This noise is generated by

refrigerant flowing in the system.)

During unit operation, a cracking

noise may be heard.This noise is

temperature changes.

Should there be a big noise from

 filter may be too dirty.
This is because the system 

circulates smells from the interior

During COOL or DRY operation, 

This is due to the sudden cooling

Is power plug inserted?

Is there a power failure?

Is fuse blownout?

Is the air filter dirty?

Are there any obstacles before 

Is temperature set correctly?

Are there some doors or 
Is there any direct sunlight

through the window during the 

Are there too much heat sources

or too many people in the room 

In dry mode, fan 

speed can’t be 

changed.

In DRY mode, when room temperature

2

o

C,unit will run

regardless of FAN setting.

during cooling operation?

cooling operation?(Use curtain)

 windows left open?

 inlet and outlet?

Normally it should be cleaned 

every 15 days.

intermittently at LOW speed 

becomes lower than temp.

indoor unit may blow out mist.

of indoor air.

air such as the smell of furniture,

paint, cigarettes.

air flow in unit operation, air 

generated by the casing expanding

or shrinking because of

be heard.At first 2-3 minutes after

unit start, this noise is more noticeable. 

will work for 3 minutes to protect the

air conditioner.

immediately until 3 minutes have

 Cautions

Before asking for service, check the following 

first.

blown out.

does not restart

Haier 

Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China
Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010

Website: www.haier.com

10

3. If the fuse of indoor unit on PC board is

it with the type of T. 3.15A/ 250V

outdoor

  broken,change it with the type of T.25A/250V

The refrigerating circuit is leak-proof.

1.Applicable ambient temperature range:

 Specifications

The machine is adaptive in following situation

The power plug and connecting cable

acquired the local 

2. If the power supply cord is damaged, it must be replaced 

manufacturer

qualified   person.

4. The wiring method should be in line with   the local wiring

5. After installation, the power plug should   be easily reached.
6. The waste battery should be disposed

   properly.

7. The appliance is not intended for use

 persons    without supervision.

8.Young children should be supervised

with

    the appliance.

9. Please employ the proper power plug,

cord.

11.In order to protect the units,please turn

30 seconds

     later, cutting off the power.

10.

Cooling

Indoor

Maximum:D.B/W.B

Maximum:D.B/W.B

D.B

Maximum:D.B

D.B

Minimum:D.B/W.B

Maximum:D.B/W.B

Minimum:D.B/W.B

Outdoor

Indoor

Outdoor

Heating

32

o

C/23

o

C

24

o

C/18

o

C

o

C/-8

o

C

46

o

C/26

o

C

18

o

C

27

o

C

21

o

C/15

o

C

Outdoor

Maximum:D.B/W.B

Minimum:D.B

24

o

C/18

o

C

-15

o

C

(INVERTER)

o

C

7

-

Minimum:

Minimum:

   or its service agent or a similar 

   broken,please

. If the fuse of 

standard.

by young children or

    to ensure that they

    which fit into the 

must have

     off the A/C first, 

by the 

change

unit is

infirm

do not play

    power supply

attestation.

and at least 

15

     Do not obstruct or cover the ventilation

conditoner.Do not put fingers

inlet/outlet and swing louver.

This appliance is not intended for use by persons (including children) 

with reduced physiced, sensory or mental capabilities or lack of 

experience and knowledge, unless they have been given supervision 

or instruction concerning use of appliance by person responsible for 

their safety. Children should be supervised to ensure that they do not 

play with the appliance.

grille of the air 

or any other things into the 

Summary of Contents for AS07ZS2ERA

Page 1: ...RATION INDOOR UNIT INSTALLAION MAINTENANCE CAUTIONS TROUBLE SHOOTING 10 INSTALACI N DE LA UNIDAD INTERIOR MANTENIMIENTO PRECAUCIONES RESOLUCI N DE PROBLEMAS PARTES Y FUNCIONES FUNCIONAMIENTO 20 PARTI...

Page 2: ......

Page 3: ...ignal display the set temperature 2 3 5 6 4 HEAT display 1 Outlet Horizontal flap Display board adjust up and down air flow Don t adjust it manually adjust left and ow Vertical blade Emergency Switch...

Page 4: ...splay to will flash And then press enter to FAN function Air Flow Direction Adjustment 1 Status display of air flow When restart after remote turning off the remote memorize the previous Move the vert...

Page 5: ...t room temperature won t be too low for your sleep 1 hours after SLEEP mode starts temp will become 2 lower than temp setting After another 1 hours temp decrease by 2 rises by 1 futher The unit will r...

Page 6: ...directive 2002 96 CE of the European parliament herewith we inform the consumer about the dis posal requirements of the electrical and electronic products conditioning system treatment of the refriger...

Page 7: ...e conne cted with the outdoor unit Place where cold air can be spread in a room entirely Place nearby a power receptacle with enough space around Place where the distance of more than lm from televisi...

Page 8: ...g the Piping Hole Cover Drawing of pipe 3 Installation of the Indoor Unit Rear piping Draw pipes and the drain hose then fasten them with the adhesive tape Left Left rear piping In case of left side p...

Page 9: ...ool Clutch type clutch type Rigid type Wing nut type Imperial type A 0 0 5mm 1 0 1 5mm 1 5 2 0mm rth leakage breaker Lean Damage of are Partial Too outside Correct Incorrect 7 On Drainage It becomes h...

Page 10: ...door unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter T...

Page 11: ...TION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or re...

Page 12: ...i tech Zone Qingdao 266101 P R China Contacts TEL 86 532 8893 6943 FAX 86 532 8893 1010 Website www haier com 10 3 If the fuse of indoor unit on PC board is it with the type of T 3 15A 250V outdoor br...

Page 13: ...ferencia Unidad exterior SALIDA DE AIRE TUBOS DE CONEXI N Y CABLEADO EL CTRICO ENTRADA DE AIRE MANGUITO DE DRENAJE Recuerde que la ilustraci n anterior podr a no reflejar fielmente el producto adquiri...

Page 14: ...amente la velocidad del mismo seg n la temperatura de la habitaci n REFRIGERACI N SECO En el modo SECO cuando la temperatura de la sala es inferior a la temperatura con gurada 2 C el equipo funcionar...

Page 15: ...RIZADOR la funci n SUE O no se podr activar Si el usuario restablece la funci n TEMPORIZADOR despu s de activar la funci n SUE O sta se cancelar la m quina activar entonces el temporizador de encendid...

Page 16: ...Todos los productos satisfacen los requisitos de las siguientes normas europeas Directiva de baja tensi n 73 23 CEE Directiva de baja tensi n 2006 95 CE Compatibilidad electromagn tica 89 336 CEE Com...

Page 17: ...l enchufe de alimentaci n en la toma compruebe que el voltaje no falla La fuente de alimentaci n es la que figura en la placa de datos nominales Instale el aparato en un circuito dedicado de alimentac...

Page 18: ...la conexi n con material aislante de calor y aseg rese de fijarla con cinta adhesiva Los cables el ctricos de interior exterior deben conectarse a la entubaci n del refrigerante utilizando cinta prot...

Page 19: ...de drenaje formando una pendiente descendiente No practique el drenaje como se muestra a continuaci n Deposite agua en la bandeja de drenaje de la unidad interior y confirme que el drenaje se realiza...

Page 20: ...ovocar defectos Cierre la rejilla de la toma de entrada 1 2 3 4 5 Una vez cada dos semanas Sustituci n del ltro puri cador de aire 1 Abra la rejilla de la toma de entrada Sujete la rejilla de la toma...

Page 21: ...uir el aparato personalmente Conecte el cable de conexi n a tierra Precauciones ADVERTENCIA Llame al departamento de ventas asistencia t cnica si desea obtener m s informaci n acerca de la Instalaci n...

Page 22: ...tamente Existen puertas o ventanas abiertas Penetra la luz solar directamente a trav s las ventanas durante el funcionamiento en modo de refrigeraci n Utilice cortinas Existen demasiadas fuentes de ca...

Page 23: ...ferimento e potrebbe non riprodurre esattamente il prodotto acquistato Unit esterna L immagine in alto solo di riferimento e potrebbe non ripro durre esattamente il prodotto acquistato Telecomando Ins...

Page 24: ...ignata Modali t timer Velocit ventola Modalit operativa Sopra i 23 C 26 C N Sotto i 23 C 23 C N Non possibile cambiare le impostazioni della temperatura e la velocit della ventola inoltre non possibil...

Page 25: ...della temperatura impostata in modo tale che la temperatura ambiente non sia troppo bassa per il sonno 2 In modalit riscaldamento 1 ora dopo che la modalit sospensione si avviata la temperatura si abb...

Page 26: ...e del Consiglio Europeo sulla limita zione dell uso di alcune sostanze pericolose nei dispositivi elettrici ed elettronici direttiva RoHS UE WEEE In conformit alla direttiva 2002 96 CE del Parlamento...

Page 27: ...necessari per l installazione I modelli adottano il refrigerante senza HFC R410A pi di 15 cm Deve essere prestata atten zione al sollevamento del tubo essibile di scarico Disposizione della direzio ne...

Page 28: ...e assicurarsi di fissare con nastro adesivo Il cavo elettrico interno esterno e il tubo flessibile di scarico devono esse re fissati insieme al tubo per il refrigerante usando del nastro protettivo Tu...

Page 29: ...so il basso Non installare lo scarico come mostrato di seguito Versare dell acqua nel raccoglitore dell unit interna ed accertarsi che sia scaricata in sicurezza all esterno Se il tubo flessibile di s...

Page 30: ...condizionatore 2 Staccare il ltro dell aria standard Far scorrere la rotella leggermente in alto per rilasciare il ltro quindi estrarlo 3 l i e r a s s i F ltro di puri cazione dell aria Inserire i l...

Page 31: ...terra AVVERTENZA Non utilizzare per conservare alimenti opere d arte apparecchiature particolari per l allevamento o la coltivazione Cambiare l aria di tanto in tanto in particola re se contemporaneam...

Page 32: ...assimo D B 27o C Minimo D B 15o C Esterno Massimo D B W B 24o C 18o C Minimo D B W B 7o C 8o C Esterno INVERTER Massimo D B W B 24o C 18o C Minimo D B 15o C Non ostruire o coprire la griglia di ventil...

Page 33: ...rence Unit ext rieure SORTIE CONNEXION DE LA TUYAUTERIE ET DU C BLAGE LECTRIQUE ENTR E TUYAU DE VIDANGE Selon l article r el achet l image ci dessus est seulement pour r f rence T l commande Installat...

Page 34: ...32...

Page 35: ......

Page 36: ...34...

Page 37: ...nt de brancher la fiche dans la prise il faut absolu ment v rifier la tension La source d alimentation correspond aux informations sur la plaque signal tique Installez un circuit d alimentation auxili...

Page 38: ...avec du ruban adh sif Le c ble des unit s int rieures ext rieures et le tuyau de vidange doivent tre fix s au tuyau de r frig rant avec un ruban protecteur Tuyauterie dans une autre direction l aide d...

Page 39: ...37...

Page 40: ......

Page 41: ...e fonc tionnement en d connectant le cordon d alimentation Ne pas diriger le souf e d air directement vers des person nes en particulier des enfants ou des personnes g es Ne pas tenter de r parer ou r...

Page 42: ...lle correctement r gl e Des portes ou des fen tres sont elles ouvertes Existe t il un ensoleillement direct venant d une fen tre durant le refroidissement Utiliser un rideau La pi ce contient elle tro...

Page 43: ...ist bei einigen Einheiten nicht verf gbar Anzeige TIMER ON ANSCHLIESSEN DER ROHRE UND DER ELEKTRISCHEN VERDRAHTUNG ABLAUFSCHLAUCH Beziehen Sie die Angaben auf das von Ihnen erworbene Ger t Die obige...

Page 44: ...h entsprechend der Raumtemperatur ein Im FAN Modus ist kein Betrieb im Ruhemodus SLEEP m glich Wenn die Ein Aus Taste zum ersten Mal bet tigt wird und der Notbetrieb startet l uft das Ger t automatisc...

Page 45: ...5 Einstellung der Luftgeschwindigkeit w hrend des Ruhemodus 1 TURBO Betrieb Im Ventilatormodus ist der Ruhemodus nicht verf gbar Wenn die Luftgeschwindigkeit vor der Einstellung des Ruhemodus auf hoch...

Page 46: ...unde Jede Bet tigung der Taste verringert die Zeit innerhalb der ersten zw lf Stunden um 30 Minuten und innerhalb der n chsten zw lf Stunden um eine Stunde Der Einstellungszeitraum betr gt 24 Stunden...

Page 47: ...nn Wenn Sie die Fernbedienung an der Wand befestigen platzieren Sie diese so dass das Ger t Signale empfangen kann wenn Leuchtstofflampen im Raum eingeschaltet sind Vergewissern Sie sich vor dem Ansch...

Page 48: ...risches Kabel Innen Au enber t W rmeisolierung Deckel f r Rohrleitung rechts Rohrauflageplatte Ablaufschlauch Rohrleitung 1 Schieben Sie den Ablaufschlauch in die ffnung der W rmeisolierung des Inneng...

Page 49: ...abelung muss dem rtlichen Verkabelungsstandard entsprechen 4 Nach der Installation muss der Netzstecker leicht zug nglich sein 5 In die feste Verkabelung muss ein Schutzschalter eingebaut werden Als S...

Page 50: ...rekte Sonneneinstrahlung im K hlbetrieb durch Vorh nge oder Jalousien Blockieren Sie Lufteinlass und Luftauslass nicht Benzin Leichtbenzin Verd nner oder chemische Reiniger k nnen die Beschichtung des...

Page 51: ...Betrieb ist Bet tigen Sie den Schalter nicht mit nassen H nden Gie en Sie kein Wasser zur Reinigung auf das Ger t Stellen Sie keine Blumenvase oder Wasserbeh lter auf das Ger t Stellen Sie keine Gegen...

Page 52: ...t Das System startet nicht sofort neu Im Entfeuchtungsbe trieb kann die Venti latorgeschwindigkeit nicht ver ndert werden Ein lautes Ger usch ist zu h ren K hlbe trieb Heizbe trieb Innen Au en Innen A...

Reviews: