SAFETY PRECATIONS

Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system.

Safety precautions described here are classified to "     WARNING" and "      CAUTION". Precautions which are shown in the column of
"      WANING" means that an improper handing could lead to a grave result like a death, serious injury, etc. However, even if precautions
are shown in the column of "     CAUTION", a very serious problem could occur depending on situation. Make sure to observe these safety
precautions faithfully because they are very important information to ensure the safety.

Symbols which appear frequently in the text have following meanings.

Strictly prohibited.

Observe instructions faithfully.

Provide a positive grounding.

When you have read through the manual, keep it always at hand for read consultation. If the operator is replaced, make sure to hand over
this manual to the new operator.

ON

OFF

WARNING

CAUTION

WARNING

CAUTION

CAUTIONS FOR INSTALLATION

The system should be applied to places as

office, restaurant, residence and the like.

The system should be installed by your

dealer or a professional installer.

When you need some optional devices such as a hu-
midifier, electric heater, etc., be sure to use the products
which are recommended by us. These devices should
be attached by a professional installer.

Application to inferior environment such as an engi-

neering shop, could cause equipment malfunction and

serious injury or death.

Installation by yourself is not encouraged because
it could cause such problems as water leakage,
electrical shock or fire accident by some improper
handing.

Installation by yourself is not encouraged because it
could cause such problems as water leakage, electrical
shock or fire accident by some improper handing.

Do not install nearby the place where may

have leakage of flammable gas.

Depending on the place of installation, a

circuit breaker may be necessary.

Drain pipe should be arranged to provide a

positive draining.

If the gas leakes and gathers around, it may cause the

fire.

Unless the circuit breaker is installed, it could

cause elecrical shocks.

Where strong winds may prevail, the

system should be fixed securely to prevent

a collapse.

Install on the place where can endure

the weight of air conditioner.

Make sure the system is grounded.

If the pipe is arranged improperly, furniture or the

likes may be damaged by leaked water.

Bodily injury could result by a collapse.

Bodily injury could result by a careless installation.

Grounding cable should never be connected to a gas
pipe, city water pipe, lightning conductor rod or
grounding cable of telephone. If the grounding cable
is not set properly, it could cause electric shocks.

CAUTIONS FOR OPERATION

You should refrain from exposing your body

directly to cool wind for a long time.

Do not poke the air inlet or outlet with a

bar, etc.

When any abnormal condition (scorching smell or oth-
ers) is found, stop the operation immediately and turn
off the power switch. Then consult your dealer.

It could affect your physical condition or cause some

health problems.

Since the internal fan is operating with a high

speed, it could cause an injury.

If you continue the operation without removing the

cause, it could result in a trouble, electric shock or fire.

The system should never be used for any
other purposes than intended such as for
preservation of food, flora and fauna, pre-
cision deices or work of art.

Do not handle switches with a wet hand.

Combustion apparatus should not be placed
allowing a direct exposure to wind of air con-
ditioner.

Incomplete combustion could occur on the apparatus.

It could cause electric shocks.

It could cause deterioration of food or other problems.

3

Summary of Contents for AD96NAHAEA

Page 1: ...INSTRUCTION MANUAL No 0010575976 DUCT TYPE AIR CONDITIONER AD96NAHAEA AU96NATAEA...

Page 2: ...10 CARE AND MAINTENANCE 11 FOR PREPARATION OF HEATING 12 IS THE UNIT INSTALLED CORRECTLY 13 INSTALLATION MANUAL FOR INDOOR UNIT 13 21 SAFETY PRECAUTIONS 3 5 PARTS AND FUNCTIONS 6 CAUTIONS 2 INSTALLAT...

Page 3: ...an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed w...

Page 4: ...ident by some improper handing Do not install nearby the place where may have leakage of flammable gas Depending on the place of installation a circuit breaker may be necessary Drain pipe should be ar...

Page 5: ...of such equip ment which generates steam condensed water may drip during cooling operation or it could cause a fault current or short circuit When operating the system simultaneously with a combustio...

Page 6: ...2 All the cables shall have got the European authentication certificate During installa tion when the connecting cables break off it must be assured that the grouding wire is the last one to be broken...

Page 7: ...PARTS AND FUNCTIONS 6 Indoor Unit Air outlet Air inlet Air inlet Duct Duct Drainpipe Air outlet Air inlet...

Page 8: ...r inlet or outlet Cooling is not sufficient Isn t sun shine invading direct Isn t any unexpected heating load generated Isn t the room much crowded Isn t the swing louver horizontal At HEATING mode If...

Page 9: ...ched into the FAN mode during cooling To prevent frost from being accumulated on the indoor unit heat exchanger it is sometimes automatically switched to the FAN mode but it will soon return to the co...

Page 10: ...o not open the inlet grill until fan stops completely Fan will continue rotating for a while by the law of inertia after operation is being stopped CAUTION Pre Season Care See that there are no obstac...

Page 11: ...ver to ordinary heating operation WARMING OPERATION Heat pump type warming Defrosting operation Atmospheric temperature and warming capacity Period of warm up With the heat pump type warming the mecha...

Page 12: ...t spring area etc The place where salt breeze blows Seaside etc The place where dense soot smoke exists The place where humidity is extraordina rily high The place where near the machine which radiate...

Page 13: ...fficiently support heavy weight When strength is insufficient injury can result from a falling of the unit Execute the prescribed installation construction to prepare for earthquakes and the strong wi...

Page 14: ...ape 2 Choose installation place 1 The chosen installation place should meet the following requirements and get the user s consent Place ensures ideal airflow distribution The passage of airflow has no...

Page 15: ...ult to the builder 3 Hanger bolts installation Use care of the piping direction when the unit is installed Hanging bolt M10 Hole in anchor Hole in plug Insert Concrete Use M10 screw bolt In order to b...

Page 16: ...ccessory Pipe cover small for insulation accessory Clamp accessory Adhesion For drain pipe use hard PVC general purpose pipe VP 25 I D 1 which can be purchased locally When connecting insert a PVC pip...

Page 17: ...rt the drain hose directly into drainage where the gas with sulfur may be generated Backwater bend Because the drain spout is at the position which negative pressure may occur So with the rise of wate...

Page 18: ...pedance of the duct is 1Pa m when the dimension of one side of the air duct is fixed as 250mm as shown below Note 1Pa m 0 1mmAg m The chosen chart of simple duct m 3 h m 3 n 100 200 300 400 500 600 10...

Page 19: ...is because of the irregular outer air mass strong wind and sunshine the humidity is increased There may be water drop on the outside of duct For cement and other new constructions even if not taking c...

Page 20: ...capacity number of fan controller is set at No 5 Rotate this switch capacity number setting No 1 No 8 Once the fan controller has trouble this linker can perform emergency assistant control When this...

Page 21: ...t may damage nut leading to leakage Check if the connection pipe leaks then do heat insulation treatment as below figure shown Only use seal cushion to bind the joint part of air pipe and heat insulat...

Page 22: ...s of the wires Use copper conductor only Select wire sizes and circuit protection from table below This table shows 20 m length wires with less than 2 voltage drop 2 Wiring connection Make wiring to s...

Page 23: ...ower than the top of the unit 1 Handing As there is no protective package for the outdoor unit so the following points merit attention 1 When forklift is used insert the fork into the holes in the bas...

Page 24: ...ation make sure that there is no refrigerant leakage Refrigerant if meeting with heaters and stoves ect in the room may produce hazardous gas Connection of refrigerant pipe 1 The joints of the refrige...

Page 25: ...or unit Diag2 Outdoor unit is above the indoor unit Liuid check ring Accumulator set 1 per 6 meters 6 During welding the gas pipe valve must be cooled down with a wet cotton cloth During welding of th...

Page 26: ...Nitrogen bottle VL VH Gauge distributor High pressure gauge Low pressure gauge Three way valve fully closed gas side Solder joint Solder joint Tightly closed Indoor unit Indoor Outdoor Access hole Co...

Page 27: ...3 minutes under 1 5MPa 15kg cm2g Serious leakage may be found Step 3 Charge for more than 24 hours under 3 0MPa 3 0kg cm2g Small leakage may be found Check for pressure decrease Without pressure decr...

Page 28: ...ory charge the refrigerant not including the construction procedure charged parts The calculation of the refrigerant charging When the connection pipe L 5 meters not need to add refrigerant If the con...

Page 29: ......

Reviews: