Installation Manual For Indoor Unit

1.  Safety precautions

WARNING

Please read these "Safety Precautions" first then accurately execute the installation work.

Though the precautionary points indicated herein are divided under two headings,

and                             , those points which are related to the strong possibility of an installation done in error

resulting in death or serious injury are listed in the                              section. However, there is also a

possibility of serious consequences in relationship to the points listed in the                           section as well.

In either case, important safety related information is indicated, so by all means, properly observe all that is

mentioned.

After completing the installation, along with confirming that no abnormalities were seen from the operation

tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment,

based on the owner's manual.

Moreover, ask the customer to keep this sheet together with the owner's manual.

This system should be applied to places as office, restaurant, residence and the like. Application to inferior

environment such as engineering shop could cause equipment malfunction.

Please entrust installation to either the company which sold you the equipment or to a professional contractor.

Defects from improper installations can be the cause of water leakage, electric shocks and fires.

Execute the installation accurately, based on following the installation manual. Again, improper installations

can result in water leakage, electric shocks and fires.

When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned

countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration.

In regards to preparing this countermeasure, consult with the company from which you perchased the equipment,

and make the installation accordingly. In the rare event that a refrigerant leakage and exceeding of threshold

concentration does occur, there is the danger of a resultant oxygen deficiency accident.

For installation, confirm that the installation site can sufficiently support heavy weight. When strength is

insufficient, injury can result from a falling of the unit.

Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons

and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit.

For electrical work, please see that a licensed electrician executes the work while following the safety standards

related to electrical equipment, and local regulations as well as the installation instructions, and that only

exclusive use circuits are used.

Insufficient power source circuit capacity and defective installation execution can be the cause of electric

shocks and fires.

Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted

to the terminal connection part, through properly securing it. Improper connection or securing can result in

heat generation or fire.

Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation

can also result in heat generation or fire.

When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the

designated refrigerant (

R410A

) within the refrigeration cycle.

Rupture and injury caused by abnormal high pressure can result from such mixing.

Always use accessory parts and authorized parts for installation construction. Using parts not authorized by

this company can result in water leakage, electric shock, fire and refrigerant leakage.

 CAUTION

WARNING

WARNING

 CAUTION

CAUTION

Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a

telephone ground wire. Improper placement of ground wires can result in electric shock.

The installation of an earth leakage breaker is necessary depending on the established location of the unit.

Not installing an earth leakage breaker may result in electric shock.

Do not install the unit where there is a concern about leakage of combustible gas.

The rare event of leaked gas collecting around the unit could result in an outbreak of fire.

For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate

it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior

items.

All manuals and user guides at all-guides.com

Summary of Contents for AD182AMEAA

Page 1: ...AD182AMEAA AD242AMEAA AD282AMEAA AD362AMEAA AD482AMEAA AD242AMERA AD282AMERA AD362AMERA Please read this operation manual before using the air conditioner Please keep this manual carefully and safely...

Page 2: ...enance 9 For Preparation of Heating Hot Keep 10 Is The Unit Installed Correctly 11 Installation Manual For Indoor Unit 12 18 Safety Precautions 3 5 Parts and Functions 6 Cautions 2 Trouble Shooting 19...

Page 3: ...lution method of disposal Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to th...

Page 4: ...handing Do not install nearby the place where may have leakage of flammable gas Depending on the place of installation a circuit breaker may be necessary Drain pipe should be arranged to provide a pos...

Page 5: ...inity of such equip ment which generates steam condensed water may drip during cooling operation or it could cause a fault current or short circuit When operating the system simultaneously with a comb...

Page 6: ...F 4G 0 75mm2 All the cables shall have got the European authentication certificate During installation when the connecting cables break off it must be assured that the grouding wire is the last one to...

Page 7: ...Parts and Functions 6 Air outlet Air inlet Duct Air outlet Air inlet Duct For series 182 242 282 362 For series 482 All manuals and user guides at all guides com...

Page 8: ...let Cooling is not sufficient Isn t sun shine invading direct Isn t any unexpected heating load generated Isn t the room much crowded Isn t the swing louver horizontal At HEATING mode If swing louver...

Page 9: ...ng To prevent frost from being accumulated on the indoor unit heat exchanger it is sometimes automatically switched to the FAN mode but it will soon return to the cooling mode Even if the operation sw...

Page 10: ...he air inlet and air outlet of both indoor and outdoor units Make sure that the air filter is not dirty Cut in the power supply switch 12 hours before starting run Post Season Care Operate the unit wi...

Page 11: ...ARMING OPERATION Heat pump type warming Defrosting operation Atmospheric temperature and warming capacity Period of warm up With the heat pump type warming the mechanism of heat pump that concentrate...

Page 12: ...area etc The place where salt breeze blows Seaside etc The place where dense soot smoke exists The place where humidity is extraordina rily high The place where near the machine which radiates the el...

Page 13: ...cient injury can result from a falling of the unit Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes etc Improper installation...

Page 14: ...r a Places where chilled or heated air circulates freely When the installation height exceeds 3m warmed air stays close to the ceiling In such cases suggest your client users to install air circulator...

Page 15: ...Indoor Unit For series 482 For series 182 242 282 362 3 Avoid installation and use at those places listed below a Places exposed to oil splashes or steam e g kitchens and machine plants Installation...

Page 16: ...tention not to apply excess force to the piping on the unit side Also fix the piping at a point as close as possible to the unit For drain pipe use hard PVC general purpose pipe VP 25 I D 1 which can...

Page 17: ...s higher than 500 mm the back flow quantity of drain at the event of interruption of the operation gets too much and it may cause overflow at the drain pan Therefore make the height of the drain pipe...

Page 18: ...duct installation work before finishing the ceiling 8 Connection of suction exhaust ducts a Duct connection position i Fresh air inlet Inlet can be selected from the side or rear faces depending on t...

Page 19: ...ent protector rated capacity A Power source wire size minimum mm2 Switch breaker A Earth leakage breaker Leak current mA Installation Manual For Indoor Unit 1 40 26 6 0 40 For series 282 362 30 30 20...

Page 20: ...circuit for more than 2m continuously CT check abnormal 3 times in 30m Fault phase short of phase out of balance greatly High pressure switch acts 3 times in 30m Low pressure switch acts in normal ru...

Page 21: ...al 3 times in 30m High pressure switch acts 3 times in 30m Fault phase short of phase out of balance greatly Communication abnormal for more than 4m continuously Communication abnormal for more than 4...

Page 22: ...gdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266500 P R China Web Site http www haier com All manuals and user guides at...

Reviews: