o not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.

T

he appliance must be stored in a room without continuously operating ignition sources(for examples: open flames, an operating gas appliance 

or an operating electric heater).

D

o not pierce or burn.

B

e aware that refrigerants may not contain an odour.

I

f the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

T

he appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not play with the appliance (For markets other than EU).

T

he wiring method should be in line with the local wiring standard.

A

ll the cables shall have got the European authentication certificate. During installation, when the connecting cables break off, it must be 

assured that the grouding wire is the last one to be broken off. The explosion-proof breaker of the air conditioner should be all-pole switch. 

Distance between it’s two contacts should not be no less than 3mm. Such means for disconnection must be incorporated in the wiring.

M

ake sure installation is done according to local wiring regulation by professional persons.

M

ake sure ground connection is correct and reliable. A leakage explosion-proof breaker must be installed.

T

he installation and service of this product shall be carried out by professional personnel, who have been trainedand certified by national training 

organizations that areaccredited to teach the relevant national competency standards that may be set in legislation.

M

echanical connectors used indoors shall comply with ISO 14903. When mechanical connectors are reused indoors, sealing parts shall be 

renewed. When flared joints are reused indoors, the flare part shall be re-fabricated.

T

his appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons

D

isconnect the appliance from its power source during service and when replacing parts

T

he maximum working pressure is 4.15 MPa.This maximum working pressure shall be considered when connecting the outdoor unit to indoor 

units.

T

he refrigerant suitable for the indoor unit is R410A/R32. The indoor unit shall only be connected to outdoor unit suitable for the same refrigerant. 

T

he unit is a partial unit air conditioner, complying with partial unit requirements of the International Standard, and must only be connected to 

other units that have been confirmed as complying to corresponding partial unit requirements of the International Standard.

T

he A-weighted sound pressure level is below 70 dB.

WARNING

Summary of Contents for AD100S2SM7FA

Page 1: ...ning 21 AD71S2SM7FA AD100S2SM7FA AD125S2SM7FA AD140S2SM7FA Keep this operation manual for future reference Original instructions This product must only be installed or serviced by qualified personnel Please read this manual carefully before installation Accessory 13 ...

Page 2: ......

Page 3: ... the inside of the stop value cover A contains fluorinated greenhouse gases covered by the Kyoto Protocol B fatory refrigerant charge of the product see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging Haier Industrial Park No 1 Haier road Qingdao P R China A B C D kg kg kg R32 WARNING If...

Page 4: ...connectionmustbeincorporatedinthewiring Makesureinstallationisdoneaccordingtolocalwiringregulationbyprofessionalpersons Makesuregroundconnectioniscorrectandreliable Aleakageexplosion proofbreakermustbeinstalled Theinstallationandserviceofthisproductshallbecarriedoutbyprofessionalpersonnel whohavebeentrainedandcertifiedbynationaltraining organizationsthatareaccreditedtoteachtherelevantnationalcompe...

Page 5: ... instructions set forth in the User s Guide Installation shall be done by professional people don t install unit by yourself For the purpose of safety the air conditioner must be properly grounded in accordance with specifications Always remember to unplug the air conditioner before opening inlet grill Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull ...

Page 6: ...jury or death Installation by yourself is not encouraged because it could cause such problems as water leakage electrical shock or fire accident by some improper handing Installationbyyourselfisnotencouragedbecauseitcould cause such problems as water leakage electrical shock or fire accident by some improper handing Do not install nearby the place where may have leakage of flammable gas Depending ...

Page 7: ...ture of the unit for any damage after a use of long period of time Insufficient ventilation could cause an oxygen deficiency accident If the structure is not repaired immediately the unit could topple down to cause a personal injury When cleaning the system stop the operation and turn off the power switch Do not put water containers on the unit such as a flower vase etc Cleaning should never be do...

Page 8: ...m 9 A leakage breaker must be installed 10 For AD71S2SM7FA AD100S2SM7FA AD125S2SM7FA AD140S2SM7FA we can get the 10 different ESP through adjust wired controller YR E17A please refer below AD71S2SM7FA AD100S2SM7FA AD125S2SM7FA AD140S2SM7FA static presssure grade static presssure Pa 0 25 37 50 70 90 100 120 130 150 0 25 37 50 70 90 100 120 130 150 25 37 50 70 90 100 110 120 130 150 AD71S2SM7FA AD10...

Page 9: ...all connected through 3 pieces of polar wire 6 Communication wiring The wire controller is equipped with special communication wiring in the accessories 3 core terminal 1 white 2 yellow 3 red is connected with the terminal A B C of wire controller respectively The communication wiring is 5 meter long if the actual length is more than it please distribute wiring according to below table Communicati...

Page 10: ...ver to ordinary heating operation Heat pump type warming With the heat pump type warming the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space is utilized Defrosting operation When a room is warmed with a heat pump type air conditioner frost accumulates on the heat exchanger of outdoor unit along with the drop of indoor temperature Si...

Page 11: ... is consumed even the air conditioner is in stop Clean the air filter and set it in the place Care and Cleaning of the unit Clean with soft and dry cloth If it is very dirty dissolve neutral detergent in the lukewarm water and make the cloth wet with the water After wiping clean off the detergent using clean water 1 Clean the air filter by lightly tapping it or with the cleaner It is more effectiv...

Page 12: ...supply power in normal Isn t the signal receiving section exposed to the direct sunlight or strong illumination Isn t the earth leakage breaker in action It is dangerous Turn off the power supply switch immediately and contact the sales dealer Power supply switch is not ON Cooling or heating is not sufficient Is the thermostat adjust as required Isn t the air filter dirty Isn t any doors or window...

Page 13: ...AN mode during cooling To prevent frost from being accumulated on the indoor unit heat exchanger it is sometimes automatically switched to the FAN mode but it will soon return to the cooling mode Even if the operation switch is turned on cooling dehumidifying or heating is not operable for three minutes after the conditioner is stopped Because the protecting circuit is activated During this time a...

Page 14: ... cross sigal detected wrong Note 1 The outdoor failure can also be indicated by the indoor unit the checking method as follo ws If the outdoor error code is M DECIMAL the indoor unit s wired controller display will show the after converted hexadecimal code of M 20 DECIMAL for example if the outdoor error code is 2 the indoor unit wired controller display will flash the error code 16 2 2 20 22 chan...

Page 15: ...ghtening the Connecting pipe 2 3 4 Brass nut gas side for AD140S2SM7FA 1 5 8 Brass nut gas side for others 1 3 Coupler heat insulation gas side 1 For indoor side pipe joint gas side 4 Coupler heat insulation liquid side 1 For indoor side pipe joint liquid side 5 Accessories group 1 Drainage fittings group 6 Instructions 1 Air conditioner operation 13 ...

Page 16: ...esult from a falling of the unit Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes etc Improper installations can result in accidents due to a violent falling over of the unit For electrical work please see that a licensed electrician executes the work while following the safety standards related to electrical equipment and ...

Page 17: ...The place where salt breeze blows Seaside etc The place where dense soot smoke exists The place where humidity is extraordinarily high The place where near the machine which radiates the electromagnetic wave The place where voltage variation is considerably large For details consult your sales dealer The electric work must be burden on the authorized engineer with qualification for electric work a...

Page 18: ...QUIPMENT MALFUNCTION AND OR PROPERTY DAMAGE Preparation of indoor unit Before or during the installation of the unit assemble necessary optional panel etc depending on the specific type Select places for installation satisfying following conditions and at the same time obtain the consent on the part of your client user Places where chilled or heated air circulates freely When the installation heig...

Page 19: ...g side Supply water Water level 0 5 mm 0 0 2 Bring the piping side slightly lower Hanging bolt M10 nut Main unit M10 washer M10 spring washer 1 Preparation for suspending the unit a Size of hole at ceiling and position of hanging bolts Combination with silent panel b Hanger bolts installation Use care of the piping direction when the unit is installed Hanging bolt M10 Hole in anchor Hole in plug I...

Page 20: ... the right figure Take care not to apply external force onto the drain pipe connection part For unit with water pump drain pipeuse hard PVC general purpose pipe VP which can be purchased locally When connecting insert a PVC pipe end securely into the drain socket before tightening securely using the attached drain hose and clamp Adhesive must not be used for connection of the drain socket and drai...

Page 21: ...Conduct a drainage test after completion of the electrical work During the trial make sure that drain flows properly through the piping and that no water leaks from connections In case of a new building conduct the test before it is furnished with the ceiling Be sure to conduct this test even when the unit is installed in the heating season Attached drain hose clamp Drain piping Main unit Drain si...

Page 22: ... sizes and circuit protection from table below This table shows 20 m length wires with less than 2 voltage drop POWER SUPPLY INDOOR OUTDOOR CONNECTION Make wiring to supply power to the outdoor unit so that the power for the indoor unit is supplied by outdoor unit terminal blocks Item Model Phase Switch breaker A Circuit breaker Overcurrent protector rated capacity A Power source wire size minimum...

Page 23: ...cury hexavalent chromium polybrominated biphenyls and polybrominated diphenyl ethers are not more than 0 1 mass fraction and cadmium is not more than 0 01 mass fraction Please recycle the refrigerant before scrapping moving setting and repairing the air conditioning for the air conditioning scrapping should be dealt with by the qualified enterprises Move and scrap the air conditioning ...

Page 24: ... our policy of continuous product improvement these dimensionsandspecificationsmaychangeatanytime Youshouldthereforecheckwithyourdealeror Haier s Customer Care Centre to ensure this flyer correctly describes the products currently available Fisher Paykel Australia Pty Ltd Level 1 1 Eden Park Drive Macquarie Park NSW 2113 Phone Customer Care 1300 729 948 Email customer care haier com au Fisher Paykel...