Installation
template
Wall
Ceilling
Drilling position
for piping
Drilling position
for anchor bolt
200mm
900mm
Select piping and drain directions. For series 24,28,36,42 only rear side(Fig.13)
B. UNDER CEILING TYPE
Using the installation template, drill holes for piping and anchor bolts(for
holes).(Fig.12)
Fig. 12
For series 14,18
1. DRILLING FOR PIPING
Fig. 13
CAUTION
60 to 70mm
12.7mm
Fig. 16
Insert the anchor bolts into the drilled holes, and drive the pins
completely into the anchor bolts with a hammer. (Fig. 16)
2. DRILLING HOLES FOR ANCHOR BOLTS AND
INSTALLING THE ANCHOR BOLTS
Install the drain hose at the rear; it should not be installed
on the top or right side.
When the directions are selected, drill 80mm and 50mm or 150mm
dia. hole on the wall so that the hole is tilted downward toward the
outdoor for smooth water flow.
3. INSTALLING BRACKETS
Fig. 17
Install the brackets with nuts, washers and spring
washers.(Fig. 17)
Spring washer
Special nut
Bracket
4. INSTALLING INDOOR UNIT
68
16 21 28
381
232
26.5
26.5
2-R2.5
10
18
7.5
4-R5
For series 24,28,36,42
Bracket (Right)
Bracket (Left)
For series 14,18
68
16
21
28
381
232
26.5
26.5
2-R2.5
10
18
7.5
4-R5
Reset the hex bolts as shown in Fig.18.
Hex bolt
8 to 13mm
Indoor unit
Fig. 18
Apply the indoor unit to the brackets.(Fig.19)
Now, securely tighten the hex bolts in both sides.
Fig. 19
Bolt
Bracket
Indoor unit
A
B
40
40
100mm
720mm
87.5mm
147mm
326mm
247mm
85
53
series
A
B
24,28
36,42
1920
1840
1240
1320
Rear (Install the drain hose
in the direction.)
Right
Wall
6mm
Fig. 15
With a concrete drill, drill four 12.7 mm dia. Holes.(Fig.15)
INSTALLATION INSTRUCTIONS
Summary of Contents for AC142ACNAC
Page 54: ...11 1 Wiring Diagram HCFU 14CL03 R1 HCFU 18CL03 R1 11 ELECTRICAL DATA ELECTRICAL DATA ...
Page 68: ...Model HCFU 14CL03 R1 HCFU 18CL03 R1 outdoor unit EXPLODED VIEWS PARTS LISTS ...
Page 70: ...12 2 Model HCFU 24CL03 R1 HCFU 28CM03 R1 indoor unit EXPLODED VIEWS PARTS LISTS ...
Page 72: ...Model HCFU 24CL03 R1 HCFU 28CM03 R1 outdoor unit EXPLODED VIEWS PARTS LISTS ...
Page 74: ...12 3 Model HCFU 36CM03 R1 HCFU 42CM03 R1 indoor unit EXPLODED VIEWS PARTS LISTS ...
Page 76: ...HBU 36CM03 R1 HBU 42CM03 R1 Outdoor Units EXPLODED VIEWS PARTS LISTS ...
Page 84: ...14 NOISE LEVEL TEST CHART NOISE LEVEL TEST CHART ...
Page 91: ...Sincere Forever Tel 86 532 8938356 Web site http www haier com ...