Cautions
If the air conditioner is used under higher
temperature condition than those listed,
the built-in protection circuit may operate
to prevent internal circuit damage. Also,
during Cooling and Dry modes, if the unit
is used under conditions of lower
temperature than those listed above, the
heat-exchanger may freeze, leading to
water leakage and other damage.
Do not use this unit for any other purposes
except for the Cooling and the Heating,
Dehumidifying, and air-circulation of
rooms should be in ordinary dwellings.
The wiring method should be in line with
the local wiring standand.
The waste battery should be disposed
properly.
If the fuse on PC board is broken, please
change it with the type T 3.15A/250VAC.
The air breaker should be all-pole switch.
and the distance between it's two contacts
should no less than 3mm.
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 -5
24 26 --
20 27 15
14.5 -- --
7 24 -15
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor DB C
WB C
DB C
WB C
*ERA :
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 10
24 26 --
20 27 15
14.5 -- --
7 24 -7
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor DB C
WB C
DB C
WB C
*EAA :
All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditoiner.
Do not damage any parts of the air
conditioner that carry refrigerant by
piercing or perforating the air conditioner's
tubes with sharp or pointed items, crushing
or twisting any tubes, or scraping the
coatings off the surfaces. If the refrigerant
spurts out and gets into eyes, it may result
in serious eye injuries.
Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers or any other things into the
inlet/outlet and swing louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Temperature and Humidity Range
For this model, the all-pole discon-rexion
connection method should be applied in
the power supply.
Such means for disconnection must be
incorporation in the fixed wiring.
Specifications
The refrigerating circuit is leak-proof.
When the indoor unit is turned on,the
PCB will test if swing motor is O.K.,and
then fan motor will start up.So there is a
few seconds to wait .
In cooling mode,the flaps will swing
automatically to a fixed position for anti-
condensating.