Ambient Sensor, Defrosting Sensor, Pipe sensor
R25
=10K
3%
B25
/50
=3700K
3%
Temp.(
)
Max.(K )
Normal(K )
Min.(K )
Tolerance(
)
-30
165.2170
147.9497
132.3678
-1.94
1.75
-29
155.5754
139.5600
125.0806
-1.93
1.74
-28
146.5609
131.7022
118.2434
-1.91
1.73
-27
138.1285
124.3392
111.8256
-1.89
1.71
-26
130.2371
117.4366
105.7989
-1.87
1.70
-25
122.8484
110.9627
100.1367
-1.85
1.69
-24
115.9272
104.8882
94.8149
-1.83
1.67
-23
109.4410
99.1858
89.8106
-1.81
1.66
-22
103.3598
93.8305
85.1031
-1.80
1.64
-21
97.6556
88.7989
80.6728
-1.78
1.63
-20
92.3028
84.0695
76.5017
-1.76
1.62
-19
87.2775
79.6222
72.5729
-1.74
1.60
-18
82.5577
75.4384
68.8710
-1.72
1.59
-17
78.1230
71.5010
65.3815
-1.70
1.57
-16
73.9543
67.7939
62.0907
-1.68
1.55
-15
70.0342
64.3023
58.9863
-1.66
1.54
-14
66.3463
61.0123
56.0565
-1.64
1.52
-13
62.8755
57.9110
53.2905
-1.62
1.51
-12
59.6076
54.9866
50.6781
-1.60
1.49
-11
56.5296
52.2278
48.2099
-1.58
1.47
-10
53.6294
49.6244
45.8771
-1.56
1.46
-9
50.8956
47.1666
43.6714
-1.54
1.44
-8
48.3178
44.8454
41.5851
-1.51
1.42
-7
45.8860
42.6525
39.6112
-1.49
1.40
-6
43.5912
40.5800
37.7429
-1.47
1.39
-5
41.4249
38.6207
35.9739
-1.45
1.37
-4
39.3792
36.7676
34.2983
-1.43
1.35
outdoor Unit
7.2 Value of thermistor
Functions and control
Domestic air conditioner
23
Summary of Contents for 2U50S2SF1FA
Page 11: ...Pinping diagrams Domestic air conditioner 4 Pinping diagrams 9 ...
Page 12: ...Domestic air conditioner 5 Operation range 10 Introduction ...
Page 83: ...Domestic air conditioner Removal of procedure 11 s t n i o P e r u d e c o r P p e t S 2 ...
Page 84: ...Domestic air conditioner Removal of procedure 12 s t n i o P e r u d e c o r P p e t S 3 ...