Functions and control
109 0.6877 0.6140 0.5478
-4.63
4.16
110 0.6700 0.5977 0.5328
-4.69
4.21
111 0.6528 0.5820 0.5183
-4.74
4.26
112 0.6361 0.5667 0.5043
-4.80
4.31
113 0.6200 0.5518 0.4907
-4.86
4.36
114 0.6043 0.5374 0.4775
-4.92
4.41
115 0.5891 0.5235 0.4648
-4.98
4.45
116 0.5743 0.5100 0.4524
-5.04
4.50
117 0.5600 0.4968 0.4404
-5.10
4.55
118 0.5460 0.4841 0.4288
-5.16
4.60
119 0.5325 0.4717 0.4175
-5.22
4.65
120 0.5194 0.4597 0.4066
-5.28
4.70
Discharging Sensor
R80
ć
=50K
¡f
3%
B25/80
ć
=4450K
f
3%
Temp.((
ć
))
Max.(KΩ) Normal(KΩ) Min.(KΩ)
Tolerance(
ć
)
-30
14646.0505
12061.7438
9924.4999
-2.96
2.45
-29
13654.1707
11267.8730
9290.2526
-2.95
2.44
-28
12735.8378
10531.3695
8700.6388
-2.93
2.44
-27
11885.1336
9847.7240
8152.2338
-2.92
2.43
-26
11096.6531
9212.8101
7641.8972
-2.91
2.42
-25
10365.4565
8622.8491
7166.7474
-2.90
2.42
-24
9687.0270
8074.3787
6724.1389
-2.88
2.41
-23
9057.2314
7564.2244
6311.6413
-2.87
2.41
-22
8472.2852
7089.4741
5927.0206
-2.86
2.40
-21
7928.7217
6647.4547
5568.2222
-2.84
2.39
-20
7423.3626
6235.7109
5233.3554
-2.83
2.39
-19
6953.2930
5851.9864
4920.6791
-2.82
2.38
-18
6515.8375
5494.2064
4628.5894
-2.80
2.37
-17
6108.5393
5160.4621
4355.6078
-2.79
2.37
-16
5729.1413
4848.9963
4100.3708
-2.77
2.36
-15
5375.5683
4558.1906
3861.6201
-2.76
2.35
-14
5045.9114
4286.5535
3638.1938
-2.75
2.34
-13
4738.4141
4032.7098
3429.0191
-2.73
2.34
-12
4451.4586
3795.3910
3233.1039
-2.72
2.33
-11
4183.5548
3573.4260
3049.5312
-2.70
2.32
-10
3933.3289
3365.7336
2877.4527
-2.69
2.31
-9
3699.5139
3171.3148
2716.0828
-2.67
2.30
-8
3480.9407
2989.2460
2564.6945
-2.66
2.29
-7
3276.5302
2818.6731
2422.6139
-2.64
2.28
-6
3085.2854
2658.8058
2289.2164
-2.63
2.28
-5
2906.2851
2508.9126
2163.9230
-2.61
2.27
-4
2738.6777
2368.3158
2046.1961
-2.60
2.26
-3
2581.6752
2236.3876
1935.5371
-2.58
2.25
Domestic air conditioner
27
Summary of Contents for 1U26JACFRA
Page 13: ...Pinping diagrams Domestic air conditioner 4 Pinping diagrams Filter Filter 11 ...
Page 14: ... Operation range Domestic air conditioner 5ˊOperation range 12 ...
Page 34: ...Dimensional drawings 8 Dimensional drawings 9 Center of gravity 3 2 Domestic air conditioner ...
Page 45: ...Seivice diagnosis Domestic air conditioner 43 ...
Page 46: ...Seivice diagnosis Domestic air conditioner 44 ...
Page 47: ...Seivice diagnosis Domestic air conditioner 45 ...
Page 67: ...Circuit diagrams Domestic air conditioner 12 2 Module board Circuit Diagram 57 ...
Page 69: ...Wall Mounted Type DC Inverter FREE MATCH NEW40 Series SERIES NEW40 ...