Domestic air conditioner
8.4.2.3 Indoor DC fan motor malfunction
Indoor Display
E14
Method of
The rotation speed detected by the Hall IC during fan motor operation is used to determine
Malfunction
abnormal fan motor operation
Detection
When the detected rotation feedback signal don’t received in 2 minutes
Decision
Conditions
Operation halt due to breaking of wire inside the fan motor.
Causes
Fan motor overheat protection
Operation halt due to breaking of the fan motor lead wires
Detection error due to faulty indoor unit PCB
Troubleshooting
* Caution Be sure to turn off power switch before connect or disconnect connector,
or else parts damage may be occurred.
Check whether terminals
on indoor pcb is well?
Electrify the machine again and turn it on in the cooling operation,
Measure voltage between the positions 1and 3 of Terminal CN5 on
the indoor PCB
the voltage is about 90-220vac
check whether motor can run
when turn on the unit
the indoor motor is damaged and need replace
Yes
No
No
Yes
Measure whether there is voltage pulse(0-5VDC)
between the positions middle wire and black wire
of Terminal CN2 on the indoor PCB
No
the indoor pcb is damaged and need replace
Pull out the terminals on the indoor
mainboard and reinsert them.
No
Yes
Is it ok?
Yes
Service diagnosis
17
Method of
Malfunction
Detection
Malfunction
n
o
i
s
i
c
e
D
Conditions
Supposed
Method of
Malfunction
Detection
Malfunction
Detection
Conditions
Supposed
Causes
Troubleshooting
Yes
Yes
Summary of Contents for 1U18BR4EAA
Page 4: ... 2 ...
Page 5: ... 3 ...
Page 6: ... 4 ...
Page 7: ... 5 ...
Page 8: ... 6 ...
Page 11: ...Piping diagrams Domestic air conditioner 3 Piping diagrams 9 ...
Page 12: ... ...
Page 21: ...Domestic air conditioner 9 2 heating capacity temp curves 19 Performance Curves Diagram ...
Page 25: ... ...
Page 26: ...1 Removal of outdoor panel 1 ...
Page 27: ...1 Removal of Electrical Box 2 ...
Page 28: ...3 ...
Page 29: ...4 ...
Page 30: ...2 Removal of Electrical Box 5 ...
Page 31: ...6 ...
Page 32: ...9 12 Removal of fan motor bracket and partition 7 ...
Page 33: ...8 ...
Page 34: ...9 13 Removal of compressor and heat exchanger 9 ...
Page 35: ...10 ...