background image

 

Dial out number 1 has two times associated with it, an On and Off time.  The OmniLT will only call this number if the time and 
days are between the Dial Out 1 On and Dial Out 1 Off times and dates. 
 
Press # to change the On and Off times - 

See Set Up Codes

 

   DIAL 

OUT 

ON:

 

   12:00 

AM 

MTWTFSS 

#=CHNG

 

 

   DIAL 

OUT 

OFF:

 

 

 

 

NEVER            #=CHNG

 

 
For example, if your normal work hours are 8 to 5 Monday through Friday, then set Dial Out 1 On to 8:00 AM MTWTF and Dial 
Out 1 OFF to 5:00 PM MTWTF.  With these settings, the system will call Dial Out Number 1 only if the alarm is activated on 
weekdays between the hours of 8:00 AM to 5:00 PM. 
 
The default for Dial Out 1 On is 12:00 AM MTWTFSS, and the default for Dial Out 1 Off is Never, so that Dial Out Number 1 is 
always active. 
 
The Time that was entered before setting an On or Off time to Never is saved, and will be redisplayed when a day is set in place 
of Never.  Setting both the Dial Out 1 On and the Dial Out 1 OFF times to Never will make Dial Out Number 1 never active. 
 

Dial Out Numbers 2-8 

 
The default Dial Out On and Off times are the same as Dial Out Number 1. 

 
Dial Order 

 
The dial order is the order in which call all will be placed if an Alarm is activated. 
 
You can have the system make up to 8 calls in the event of an alarm.  You may chose from Dial Out Numbers 1 - 8.  You can 
have the system dial a number twice (or more) which is suggested if you don't have a direct dial number at work, so that your 
company operator can find you, if you aren't at your desk, and have you alerted for the next call. 
 
Up to eight numbers may be entered.  Enter the Dial Out Order by pressing the keypad digits 1, 2, 3, 4, 5, 6, 7, or 8 for Dial Out 
Numbers 1, 2, 3, 4, 5, 6, 7, or 8, respectively.  When you have entered the dial order of your choice, press ' # '.  Enter a single ' 0 ' 
if no dial out is desired.  The default Dial Order is 1 2 3 4 5 6 7 8. 
 
 

Set Up Arming 

 
To configure different arming and disarming options, from the Setup menu, press the 5 (ARM) key. 

 
Entry Delay 

 
The Entry Delay is the time, in seconds, that you have to turn off the alarm after entering your home.  The entry delay 

only

 

applies to the entry/exit zone (i.e. your doors).  If you (or someone else) come in through a window, there will be no entry delay 
and the alarm will sound immediately. 
 
When you come in through a door on an entry/exit zone, the other zones are delayed too.  This allows you to get to your phone or 
console to turn off the security system, even if you have to go through a room protected by a motion detector. 
 
Some doors (a back door or garage door) may be configured as a double or quadruple entry delay.  If so, that door has two times 
or four times the entry delay shown on the display. 
 
The default entry delay is 15 seconds.  If you wish to allow yourself more time to get in and turn off the security system, you may 
set the entry delay between 15 and 45 seconds. 
 
 

 

 

ENTRY DELAY:          15

 

 

 

 

15-45 SECONDS          

 

 
The console will beep and the new entry delay will be displayed. 

61 

Summary of Contents for SECURITY SYSTEM

Page 1: ...Owner s Manual Document Number 21R00 1 Rev 2 11 January 2006...

Page 2: ...Document Number 21R00 1 Rev 2 11 January 2006 Copyright 2000 2006 HAI All Rights Reserved www homeauto com...

Page 3: ...6 About CentraLite 16 About Lutron RadioRA 16 About ALC 17 ALC Module Types 17 About X 10 17 House Code 17 Unit Numbers 17 Scrolling Through Names 18 Controlling Units 18 Controlling a Room of HLC Lig...

Page 4: ...ow the OmniLT Voice Dialer Works 43 Exit Delay 62 What the OmniLT Voice Dialer Does 43 Audible Exit Delay 62 What You Hear If Your OmniLT Calls You 44 Entry Exit Chime 62 Entering the Code 44 Perimete...

Page 5: ...t that there are any questions please call your installer first If you need assistance directly from the manufacturer call us at 985 624 4008 between the hours of 9 00 AM and 5 00 PM Central Time Mond...

Page 6: ...he Day mode In the Day mode the perimeter zones doors and windows are protected however the interior zones are not armed so that you may move about freely inside In this mode there is an entry delay o...

Page 7: ...tered digits and will prompt you to reenter the number 12 KEY The Key is used to enter or confirm a selection It may also be used to display a menu or to offer you additional choices Normal Top Level...

Page 8: ...ing menu choices are available 1 CONTROL 2 SECURITY 3 BUTTON 4 ALL 5 TEMP 6 STATUS 7 EVENTS 8 MESSAGE 9 SETUP Menu 1 Selects Control functions for controlling lights and appliances Menu 2 Selects Secu...

Page 9: ...ance Your OmniLT controller and the consoles are designed to require very little maintenance For smoke detectors motion detectors and other components not manufactured by HAI and follow maintenance pr...

Page 10: ...de again Practice disarming your system until you are comfortable with this procedure NOTES Panic Tamper and Fire zones are always armed as are the Emergency buttons on the console In the event that t...

Page 11: ...e as Day mode however there is no Entry Delay on any of the security zones There will be an instant alarm if any of the zones are violated while in this mode 6 NIGHT DLY NIGHT DELAY Functions same as...

Page 12: ...E BYPASSED to remind you that the zone is bypassed If a fire zone is bypassed the console will continue to beep until that zone is restored See Restoring Zones Auto Bypass In order to prevent the alar...

Page 13: ...conds The When Alarm macro is activated Any units programmed to come on will do so The Flash For Alarm Unit Number begins to flash on and off The system now waits the Dial Out Delay 0 60 seconds If pr...

Page 14: ...s activated the alarm responds exactly as described under Burglar Alarm Activated except The console display reads GAS ALARM ZONE NAME TRIPPED The sounder will pulse on off on then an extended off per...

Page 15: ...r a description of when to use In the event that you enter your duress code or a Duress zone is tripped the system performs a silent dial out as follows No alarms lights or console beepers are activat...

Page 16: ...executed 1 hour later or when a Status Test command is given COMMUNICATOR TRBL NOW or HAD TRBL Indicated if the digital communicator not the voice dialer was unable to make contact with the Central St...

Page 17: ...nd 3 keys simultaneously Press OFF and enter your Code to cancel the alarm and silence the siren 2 To test the security zones you will need a partner to walk around your home and open and close all do...

Page 18: ...eating and air conditioning systems Direct Relay Control for sprinklers lighting electric heating etc An OmniLT will control 16 UPB switches modules and keypads 2 rooms of HLC Lighting 16 CentraLite l...

Page 19: ...s 9 16 Each room can consist of a maximum of 8 HLC devices configured as follows Up to 7 HAI UPB Wall Switches Dimmers and or Modules for controlling up to 7 lighting loads in a room or area 1 or more...

Page 20: ...rooms it must be set to the last unit number in one of the respective rooms For example set the House Controller to Unit 8 or 16 to control rooms 1 2 This allows you to have up to 2 House Controllers...

Page 21: ...ol the modules individually When a module hears a command from the OmniLT for its house code and unit number it executes the command There are 3 different X 10 formats Standard X 10 Preset Dim Extende...

Page 22: ...d room on all lighting loads in the room are turned on Press 2 A to set all of the lighting loads in the selected room to their preset levels for Scene A Press 3 B to set all of the lighting loads in...

Page 23: ...ed lighting load on Press 2 DIM to dim the selected unit 1 9 steps each step is 10 from its current level Press 3 BRT to brighten the selected unit 1 9 steps each step is 10 from its current level Pre...

Page 24: ...hen a RadioRA device transmits a signal i e Switch or Dimmer is turned on or off locally Mater Control button is pressed or Phantom Button is executed OmniLT will automatically update the status of ea...

Page 25: ...ress 0 OFF to turn the selected unit off Press 1 ON to turn the selected unit on Press 2 DIM to dim the selected unit 1 9 steps each step is 10 from its current level Press 3 BRT to brighten the selec...

Page 26: ...atus of the X 10 unit Internal Flags The easiest way to define a flag it to refer to it as a virtual relay A flag can be in one of three separate states On Off or set to a value between 0 and 255 If a...

Page 27: ...rogram the All On and All Off macro to execute an All On Scene and an All Off Scene on the CentraLite RadioRA Program the All On and All Off macro to execute Phantom Button 16 All On and Phantom butto...

Page 28: ...X 13 X X X X 14 X X X X 15 X X X X UNIT NUMBERS 16 X X X X X Corresponds to the unit numbers in a Scene Scene Commands Scene Commands are used to Set Scenes issue a Scene On command and issue a Scene...

Page 29: ...ir preset light levels at their preset fade rates For instance in our All On and All Off example when Link 50 On is transmitted by OmniLT each UPB Wall Switch with Link 50 will go to 100 to achieve th...

Page 30: ...CentraLite Scenes commands from the top level display or from the main menu press the 4 ALL key on the console keypad and then press the 5 CENLIT key You are prompted to enter a Scene 1 255 ENTER SCEN...

Page 31: ...ergy savings comfort and convenience by setting the HVAC system s to the proper temperature based on whether you are home asleep away or vacation The temperature can be reported as well as controlled...

Page 32: ...L ENTER TEMPERATURE Upstairs TEMP ENTER TEMPERATURE Enter the desired temperature then press the key The fan control on a thermostat may be switched between on and auto by selecting 4 FAN from the tem...

Page 33: ...thermostat operates normally Your thermostat should be set to the desired comfort temperature Only when the energy saver is on will the temperature be allowed to deviate from your normal thermostat se...

Page 34: ...Modules Upstairs 0 OFF 1 ON 2 HEAT Upstairs 3 COOL 4 TIME STAT For temperature sensors Upstairs 2 LOW 3 HIGH STAT To set a temperature setpoint press 2 HEAT or 3 COOL For Celsius temperatures press th...

Page 35: ...ure The Model 31A00 1 Temperature Sensor is used for sensing temperatures from 0 F 120 F and 31A00 7 Extended Range Temperature Sensor is used for sensing temperatures from 40 F 120 F It features a ne...

Page 36: ...midity from 0 to 100 percent or for sensing the outdoor temperature and or reporting the outdoor relative humidity High and low humidity limits can be set for taking action i e turning on the bathroom...

Page 37: ...e of the first unit in the respective group is used otherwise the room number is used Links every device in each room is programmed with 6 consecutive Links starting with Link 1 for example every devi...

Page 38: ...r at least 3 seconds 2 All of the LED indicators will blink to indicate that the HAI UPB 6 Button Room Controller is in Setup Mode Note The HAI 6 Button Room Controller will automatically exit Setup m...

Page 39: ...t shows how the OmniLT is currently using the phone line IDLE NOT USING THE PHONE LINE LOCAL LOCAL ACCESS REMOTE REMOTE ACCESS VOICE IN VOICE DIAL OUT MODE EMGACC ACCESS AFTER VOICE DIAL OUT DCM IN DI...

Page 40: ...s happenings and trouble conditions in the system When a new event occurs the oldest one is lost The following Events along with the time and date of their occurrence are recorded in the Event Log whe...

Page 41: ...ssages To enter the Message menu from the top level display or from the main menu press the 8 MESSAGE key on the console MESSAGE 1 SHOW 2 LOG 3 CLEAR 4 SAY 5 PHONE 6 SEND Show Message The 1 SHOW key a...

Page 42: ...selected voice message Send Message Pro Link The 6 SEND key allows you to send any of the text messages through the Pro Link serial port You are first prompted to specify the desired serial port SERIA...

Page 43: ...n ASCII message that is over 15 characters OmniLT only processes the last 15 characters of the message Pro Link determines that a message has been received when One or more characters have been receiv...

Page 44: ...OmniLT picks up or hangs up This is normal To access your OmniLT from an in house phone Pick up the receiver of any Touch Tone phone in your house Pause for just a moment about a second then press th...

Page 45: ...PERATURE 6 STATUS 7 EVENT 8 PHONE 9 GOOD BYE CANCEL 0 REPEAT This means that you press 1 for Control functions 2 for Security 3 for Button etc Pressing one of the keys on the phone will move you to an...

Page 46: ...he Phone On an in house phone only you can activate the Police Emergency keys by picking up the phone and pressing the key 6 times This activates the sounder immediately The first that you press logs...

Page 47: ...ll the premises If a Two Way Audio Module is being used after the transmission of the alarm to the central station the operator can talk and listen to people and sounds at the premises If the digital...

Page 48: ...talking If you enter the correct Master or Manager code you will then be logged in a remote phone access is logged in the event log and further dial outs are canceled You will hear the status of the...

Page 49: ...the Setup menu press the 1 CODES key Use the arrow keys to scroll through the codes User Code 1 is always set to a Master code The existing code number is not shown on the display To change the code e...

Page 50: ...ill sound no lights will flash but the OmniLT will perform a silent dial out and say that this is a silent alarm To stop a silent dial out turn your security system off by pressing OFF then your code...

Page 51: ...nd return to the Set Up Programs menu Once the new program is entered the display will return to the Set Up Programs menu 2 Show Programs The 2 SHOW key is used to review edit and delete existing prog...

Page 52: ...key to edit the selected program The Edit Program menu is displayed which allows the various parts of the program to be changed See Edit Program Edit each part of the program as specified under Edit...

Page 53: ...me or button event that activates the program to be changed The display shows EDIT WHEN 1 TIMED 2 BUTTON Times Programs Selecting 1 TIMED sets the program to be activated at a specific time of day You...

Page 54: ...mber followed by the key or by using the arrow keys to scroll through a list of buttons Pressing the key first will bring up a menu of event button types BUTTON TYPE 1 CTRL 2 SEC 3 ZONE 4 ALL 5 ALARM...

Page 55: ...Keypad RadioRA Master Control ALC 4 Button 1 2 On Button 1 or E 1 1 2 3 Off Button 2 or F 2 2 3 4 A 3 or G 3 3 4 5 B 4 or H 4 4 5 6 C 5 or I 5 6 7 D 6 or J 6 7 8 7 or K 7 8 9 8 or L 8 9 10 9 10 11 10...

Page 56: ...ctivation event You are first prompted to enter the desired zone number ZONE ENTER ZONE The zone number should be entered followed by the key or the arrow keys may be used to scroll through a list of...

Page 57: ...ccurrence of an alarm You are first prompted to select the type of alarm SELECT ALARM TYPE ANY TYPE The arrow keys are used to select from a list of alarm types ANY ALARM BURGLARY ALARM FIRE ALARM GAS...

Page 58: ...PHONE OFFHK WHEN PHONE ONHOOK WHEN AC PWR OFF WHEN AC PWR ON WHEN BATTERY LOW WHEN BATTERY OK WHEN DCM FAIL WHEN DCM OK WHEN CAMERA PA Access only When a camera input 1 6 is pressed on an OmniTouch w...

Page 59: ...following menu is displayed 1 CONTROL 2 SECURITY 3 BUTTON 4 ALL 5 TEMP 6 ENERGY 8 MESSAGE After the command is specified the display returns to the Edit Program menu Program Control Commands Press the...

Page 60: ...cess Software you can create programs to toggle any unit 1 36 from its current state to the opposite state When the program is executed the unit will toggle to Off if the unit is currently in a non of...

Page 61: ...Program Temperature Commands Select the 5 TEMP key to command thermostats energy saver modules and temperature sensors Specify the desired temperature command See Temperature Program Energy Cost Selec...

Page 62: ...pecified security zone is either Secure or Not Ready The display prompts you for the zone number ZONE ENTER ZONE Enter the zone number followed by the key or use the arrow keys to select the zone The...

Page 63: ...the DAY key to specify a pause of 2 seconds shown as a T on the display Press the NIGHT key to enter a into the number Enter a single for no number Telephone Access The Telephone Access item allows y...

Page 64: ...where your system is installed To enter phone numbers press the keypad keys 0 9 You can put in a dash for legibility by pressing the Off key Press the key after you have pressed all of the digits in...

Page 65: ...ested if you don t have a direct dial number at work so that your company operator can find you if you aren t at your desk and have you alerted for the next call Up to eight numbers may be entered Ent...

Page 66: ...es Enable Quick Arm The Quick Arm feature allows the security system to be armed by pressing the desired mode key twice instead of having to enter your code The default setting for Enable Quick Arm is...

Page 67: ...tem enables the system to speak the type of alarm and zone over a speaker on premises When an alarm first occurs the siren is activated After a few seconds the siren is turned off and the type of alar...

Page 68: ...units If the House Code All Off setup item is set to No OmniLT will not change the status of units on that House Code House Codes All On This feature allows you to choose if the House Code will respon...

Page 69: ...ation where the OmniLT is installed The latitude and longitude for a particular location may be obtained from an almanac or map of the area These values should be entered to the nearest degree The val...

Page 70: ...he key then use the arrow keys to scroll through the list Press the key to make the new selection NUMBER DESCRIPTION 1 First Sunday 2 Second Sunday 3 Third Sunday 4 Fourth Sunday 5 Last Sunday 6 Next...

Page 71: ...enter the Set Up Voice menu from the Setup menu press the 8 VOICE key SET UP VOICE 1 CTRL 2 ZONE 3 BTTN 4 CODE 5 TEMP 8 MSG Select the item that you would like to name with a voice description by pres...

Page 72: ...RESIDENCE 1234 JOHNSON STREET CORNER OF JOHNSON AND THIRD STREET The unit will beep after 8 seconds then play the address back to you If you are not happy with the sound re record by pressing 9 and t...

Page 73: ...rovide warning in the event of a fire It is your responsibility to plan your escape routes in the event of a fire alarm Your family should practice fire drills periodically to ensure that everyone is...

Page 74: ...f changes so as to give you an opportunity to maintain uninterrupted service 6 In the event of equipment malfunction all repairs should be made by our company or an authorized agent It is the responsi...

Page 75: ...nnections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users shou...

Page 76: ...ce Fuse Polyfuse 9 A Output Fuse Polyfuse 3 A Battery Fuse Polyfuse 2 5 A Polyfuses are permanent fuses that do not need replacement Nominal Output Voltage 10 13 8 VDC Low Voltage Cut Out approx 9 VDC...

Page 77: ...0 1 2 3 4 5 6 7 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 8 9 A B C D E F G H I J K L M N O 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 P Q R...

Page 78: ...VE FIFTY SIX SIXTY SEVEN SEVENTY EIGHT EIGHTY NINE NINETY A M P M WELCOME TO OMNI PAUSE SHORT PAUSE AC POWER ACCESS ADDRESS ALARM ALL 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57...

Page 79: ...BYE GOTO GUEST GUN HAD HALL HEAT HIGH HOLD HOURS HUNDRED INSTANT INTERIOR INVALID IS KITCHEN LEFT LEVEL 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132...

Page 80: ...OTE REPEAT RESTORE RIGHT RISE ROOM SAVER SECONDS SECURE SECURITY SETTING SHOP SIDE SILENT SOUTH SPA STAIRS STAR STATUS STEPS STORAGE SUN SYSTEM OK TALK TAMPER TEMPERATURE TEN THEN 178 179 180 181 182...

Page 81: ......

Page 82: ...NOTE TO INSTALLER Following installation this manual shall be left for the homeowner s use HAI New Orleans LA U S A...

Reviews: