“extend” the scale length with 500mm / 18”. A larger diameter than the physical scale length can now be
captured in the Digitech caliper.
1.
Measure the diameter manually up to 500mm / 18” and put a mark on the tree stem.
2.
Double the scale according to the above.
3.
Register the remaining section standard procedure.
3-KEY REGISTRATION
Choose species‘d’ and press E, keeping the key depressed. Move the caliper jaws to zero (0) and release the E
button. The scale length will temporarily be expanded with 500 mm / 18” .A larger diameter can now be
stored. See Double scale function above.
DELETE LATEST REGISTRATION
By keeping the L key pressed for a while, it is possible to delete the latest registration made. When doing this,
the total number of registrations is shown in the display and the updated total number after deletion has been
completed.
READING HEIGHTS FROM VERTEX AND VERTEX LASER HEIGHT MEASURERS
Activate the reading by pressing the R key for a short while. When ’IR’ is continuously shown in the display,
data can be sent from the Vertex and/or Vertex Laser instrument.
Data is transferred from the Vertex/Vertex Laser height measurer when pressing the IR key on the instrument
(turn to the instruments manual for details on measuring result transmission). Repeat the process if necessary
(for example if the Digitech caliper did not respond to the IR transfer).
NOTE: It is important to aim the IR exit port on the instrument towards the IR input on the Digitech to transfer
data.