13
Accessories
Cross-over valve, COCB 1000
Emergency stop manifold, VECA
The VECA manifold can be mounted directly on
the
Compact motor. The VECA manifold can be
con-verted for either clockwise or counter clockwise
mo tor shaft rotation. The VECA manifold gives a very
quick stop and can be integrated in most com mon
control systems.
Screws and O-rings are included
in deli ve ry.
The valve is designed for use with Compact motors
CA 50 - CA 210. The valve is bolted directly on the
motor, and the valve protects the motor and system
from too high pressure, if the motor is suddenly
stopped. The relief valves have a standard pressure
settings of 350 bar (5075 psi), but are fully adjustable
between 50 bar (500 psi) to 350 bar (5075 psi).
Screws and O-rings are included in deli ve ry.
Diagram 2
Pressure loss, COCB
Diagram 3
Schematic diagram, VECA
Fig. 19
COCB
Fig. 20
VECA
Am-Cm
0
10
20
30
40
50
60
0
100
200
300
400
500
600
700
800
900
1000
Q(l/min)
dP(
bar
)
0
100
200
300
400
500
600
700
800
0
50
100
150
200
250
Q(gallon/min)
dP(psi)