background image

07

Connecting to the IP network

ATTENTION!
We recommend installing the 

system in a segmented LAN 

network (separated from any 

other use) and protecting it with 

a fi rewall.

ç

The outdoor station is connected to the in-

door stations and the local IP network via the 

TJA470 / TJA510N gateway.
The outdoor station is commissioned via the 

confi guration interface of the appropriate 

gateway.

Switch

LAN / WLAN

Confi g-

uration

Fig. 28: Connecting to the IP network

Mounting of the outdoor station

The installation housing is mounted and the 

required connection cables in the housing 

have been prepared.

Connect the connection cables and 

network cables to the outdoor station 

according to Figure 28.

Stick the size of the two-part cable entry 

seal (22) required for the cables in the 

connection compartment cover plate (21) 

and in the connection compartment of the 

outdoor station. Then, insert the connec-

tion compartment seal (23) in the recess 

provided around the connection compart-

ment and then close it by screwing on 

the connection compartment cover plate 

(Figure 29).

(21)

(22)

(22)

(23)

Fig. 29: Cable entry, outdoor station

(21) Connection compartment cover plate

(22) Two-part cable entry

seal

(23) Connection compartment seal

Attach the outdoor station to the top two 

straps of the installation housing and 

swing it to the installation housing at the 

bottom (Figure 30).

A

B

Fig. 30: Insertion of the outdoor station

Using the safety screw (10), screw the 

outdoor station to the installation housing 

at the bottom centre (Figure 31).

(10)

Fig. 31: Securing the outdoor station

RFID cards

The RFID cards are contactless cards from 

the MIFARE DESfi re range with a unique 

serial number (UID), which is used as an 

identifi er.
There are 3 types of RFID cards, with diff er-

ent access authorisations:

The 

Confi guration card

 for the 

electrician (white corner), allowing 

local polling and setting of various 

parameters.

 The Confi guration card is set at the factory 

for the confi guration of this outdoor station 

and, initially, only works with this outdoor 

station. At a later time, the card can also 

be assigned to other outdoor stations.

The 

Registration card

 for the 

administrator (white banner).
It allows the display of the PIN 

codes, the addition of RFID cards 

and the teaching-in of faces for 

facial recognition (RTQ521

X

 ).

 The Registration card is set at the factory 

for the confi guration of this outdoor station 

and, initially, only works with this outdoor 

station. At a later time, the card can also 

be assigned to other outdoor stations.

The 

User card

 for the tenant 

(completely blue ), authorising the 

user to open the door.

 The User card can be registered on multi-

ple outdoor stations.

Confi guration via the touch display

The Confi guration card allows the local 

settable of some parameters directly on the 

outdoor station.

Hold the 

Configuration card

 (white cor-

ner) in front of the RFID card reader of the 

outdoor station to identify yourself.

Fig. 32: Identifi cation with the Confi guration 

card

The 

settings

 (Figure 33) appear on the 

touch display.

Select the setting to be changed on the 

touch display (Figure 33) and follow the 

instructions on the display.

Summary of Contents for RTQ520X

Page 1: ...nection terminal block 2 PIN 3x Diode 1x Connection terminal block removal aid tool RFID card 1x RFID user card For reordering RTH303X 3 pcs RTH310X 10 pcs 1x RFID registration card 1x RFID configuration card Optional accessories scope of delivery Flush mounted installation housing RTW021X 1x Flush mounted instal lation housing 4 x PH2 cross head screw M4x40 mm 2x Plaster masks 4 x PH2 cross head ...

Page 2: ... an alcohol based cleaning agent Do not use any abrasive polishing agents These can cause destruction through microscratches on the surface Do not use a citrus based glass cleaner This can cause the metal components on the surfaces to oxidise Information for electricians Installation and electrical connection DANGER Touching live parts in the instal lation environment can result in an electric sho...

Page 3: ...igure 10 11 115 0 1 2 1 2 m 1 2 Fig 10 Camera aperture angle horizontal 6 3 2 1 6 1 3 m 1 2 m Fig 11 Camera aperture angle vertical Flush mounting of installation housing 350 120 25 51 52 26 26 36 5 36 5 55 138 102 149 149 55 34 Fig 12 Dimensions flush mounted installa tion housing 30 42 357 115 Fig 13 Dimensions flush mounted installa tion housing insert Hold the installation housing in the correct...

Page 4: ... also bear in mind the following Close any cracks holes and openings in order to prevent any air circulation Depending on the masonry fasten the housing with building foam or cement filler suitable for outdoor areas and wait the relevant amount of time for it to harden or Attach the housing to the wall with screws and dowels via the fixing holes at the back Mounting of the hollow wall installation...

Page 5: ...its can then be found at www hager com Number of residential units per system Max 255 with own bus address Number of indoor stations Max 3 in paral lel per residential unit more than 3 possi ble by using secondary line couplers Number of users names Max 1000 per outdoor station RTQ52xX Number of users Max 1000 per TJA470 TJA510N Number of users per residential unit Max 5 maximum number of RFID car...

Page 6: ...th further indoor stations outdoor stations and acces sories devices Figure 23 The second HTG911H power supply shown hatched is only required for the variant without PoE 2 Fig 24 Installation example multi dwelling building shown unresolved KNX IP 3 NO COM Fig 25 Installation example multi dwelling building shown resolved LOOP_OUT LOOP_GND RELAY_NC1 PWR_IN PWR_GND RELAY_COM1 RELAY_NO1 GND WG_D1 WG...

Page 7: ...installation housing at the bottom centre Figure 31 10 Fig 31 Securing the outdoor station RFID cards The RFID cards are contactless cards from the MIFARE DESfire range with a unique serial number UID which is used as an identifier There are 3 types of RFID cards with differ ent access authorisations The Configuration card for the electrician white corner allowing local polling and setting of vario...

Page 8: ...munication problems possi ble between the devices during automatic assignment Ensure the use of fixed IP addresses in agreement with the system administrator ç Automatic assignment For the automatic network setting position DHCP on On Figure 36 The automatically assigned addresses appear in the Network menu Netzwork Alternate DNS Server Gateway Subnet mask IP address 192 168 1 1 192 168 1 1 192 16...

Page 9: ...er of the out door station to identify yourself Fig 40 Fig 40 Identification with the Registration card Registered users appear on the touch display Figure 41 Select the user on the touch display Users ARMANI Eric Tesla CAISSON Romain Tesla BATELOT Jessica Tesla DREISSEN Anna Tesla FROMMWEILLER Thomas Dismiss Fig 41 Display of registered users Select the access option to be changed on the touch di...

Page 10: ...tries with separate collection systems This marking shown on the product or its documentation indicates that it should not be disposed of with other household waste at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this device from other types of waste Recycle the device responsibly to promote the sustainable...

Reviews: