background image

4

6LE001524A

H

ag

er

 0

9.

20

15

O

C

O

M

 1

14

40

8

• Press key 

e

+

to select to affect the group of

five days (the group of five days flashes). 

Confirm using the 

OK 

key.

• P1 flashes. Press key 

e

+

to select P2 (

P2

flashes). Confirm using the 

OK 

key.

• Press key 

e

+

to select the group of 2 weekend

days (the group of 2 weekend days flashes).

Confirm using the 

OK 

key.

• 

P1

flashes. Confirm using the 

OK 

key.

The thermostat returns to 

auto 

mode.

Creation of a personalised program P4 

This program allows you to adjust the heating to

suit your way of life. A 24-hour profile is composed

of 48 points (representing the set-points). You can

visualise the composition of your program at the

bottom of the display.

1 program step = 30 minutes.

Example : creating a program, 

P4

for a group of

days (5 we 2 weekend days).

For the 5 weekdays, we would like 3 Comfort

periods from 06:00 to 08:00, from 12:00 to 14:00

and from 18:00 to 22:00.

For the two weekend days, we would like a

Comfort period from 08:00 to 19:00, then a

Comfort 2 period from 19:30 to 22:00.

• Press key 

menu

to place the cursor

under 

prog

. The indicators for the seven days of

the week flash.

• Press key 

e

+

to select to affect the group of

five days (the group of five days flashes). Confirm

using the 

OK 

key.

• P1 flashes. Press key 

e

+

to select P4 

(

P4

flashes). Confirm using the 

OK 

key.

• Press key 

a

until 6:00 appears and then key 

until 8:00 appears. Then press key 

a

until

12:00 and key 

until 14:00. Then press key

a

until 18:00 appears and finally key 

until 22:00.

If you make an error, press key 

-

to move

backwards or key 

e

+

to advance and correct

your programming.

• Confirm using the 

OK 

key.

• The group of 2 weekend days flashes. Confirm

using the 

OK 

key.

• 

P1

flashes. Press key 

e

+

to select P4

(

P4

flashes). Confirm using the 

OK 

key.

• Press key 

a

until 8:00 appears and

key 

until 19:30 appears. Then press key 

until 22:00 and press key 

a

until 24:00. 

Confirm using the 

OK 

key.

Note : 

The latest P4 program is held in memory and auto-

matically offered to be assigned to a new day or

group of days (whose P4 is empty).

Setting anticipation to 1 sends program 

P4 => P4A.

If the 

anticipation 

function (

1H

2H

or 

3H

) ) in the

Installer parameters PA:9

has been confirmed, 

P4A

is

displayed in place of 

P4.

during programming, proceed in the same way as

for 

p4

knowing that the thermostat will automati-

cally apply the anticipation with the duration set in

pa:9

. it is not useful to foresee this anticipation time

during your programming.

30 min.

in Eco

30 min.

in Comfort

30 min.

in Comfort 2

Technical characteristics

Power supply: 2 alkaline batteries 1.5V (type LR06)

Battery lifespan: 4 years

Static differential (On/Off regulation) : < 0.3 °C

Power reserve: 10 min

Adjustment range

- Comfort temperature: +5 °C to +30 °C

- Comfort 2 temperature: +5 °C to +30 °C

- Eco temperature: +5 °C to +30 °C

Ambient temperature display range: 0 °C to +40 °C

Operating temperature: +0 °C to +45 °C

Storage temperature: -25 °C to +70 °C

Ball test temperature: 75 °C and 125 °C

Clock operating accuracy: drifts < 1sec/day

Trip values: 250V max. 5A resistive/3A inductive

Minimum load excepted by the relay: 12V / 10mA

Relative humidity: 90 % at 20 °C

IP: 30

Ecodesign class:4  

IK: 04

Insulation class: II

Insulation type: 4 kV

Rigid cable cross-sections: 0,5 to 2.5 mm²

Flexible cable cross-sections: 0,5 to 1.5 mm²

Minimum pulse voltage: 4 kV

Pollution class: 3

Action type: 2B

Insulation type: reinforced insulation

Software structure: class A

Dimensions (l x h x d): 97 x 138 x 30

Standards: NF EN 60730-1, NF EN 60730-2-1,

NF EN 60730-2-7, NF EN 60730-2-9,

NF EN 60730-2-11

EN 12098-2, EN 12098-5.

Temporary overrides

By overriding until the next program step,

in 

auto

mode, it is possible to modify the temperature

of the current set-point.

• Press key 

+

or 

-

to increase or reduce

the temperature of the displayed set-point.

The set-point temperature flashes and the override

is valid until the next step of the program. 

During the override period, the current set-point

temperature flashes.

Temporary override

In auto mode, this function allows temporary 

modification of the ambient temperature, at any

time, whatever the instruction in progress. The

range of duration of this function is from 15 minutes

to 12 hours.

• Press key 

, the duration adjusted in 

PA:1

flashes

• Press key 

e

+

or 

-

to adjust the desired duration.

Confirm using the 

OK 

key.

• Press key 

e

+

or 

-

to adjust the desired 

temperature. Confirm using the 

OK 

key.

The end time of the temporary override flashes

on the bar chart of the screen and the value of

the duration of the temporary override is displayed

in place of the current time, until the return to 

auto-

matic mode.

If a temporary override is in progress, it is possible

to modify the temperature in steps of 0.5 °C using

key 0,5 °C 

e

+

or 

-

.

One press on key 

allows the delay time to be

modified; the last selected duration is displayed

Accessories

Telephonic remote control

The thermostat is equipped with an input for 

telephonic commands for your heating.

The symbol

is displayed if the Frost protection

mode is requested telephonically. Detection of

telephonic remote commands is taken into account

in less than 1 minute. You can modify the Frost

protection temperature using the Holiday 

menu

.

The temperature applied will be the last value

confirmed in 

Holiday

mode. In Air conditioning

mode, during telephonic forcing the regulation is

stopped.

What to do if... ?

The symbol  is displayed:

change the batteries (2 alkaline batteries of type

LR06 1.5 V) as soon as possible.

The symbol  is displayed:

the thermostat is locked in Frost protection mode

by telephonic remote control.

Unlock the function by a telephone call or using

the remote control.

The heating does not start up, even though the

ambient temperature is less than the set point:

function of the evolution of the ambient

temperature over the last few hours.

The thermostat estimates that the temperature will

be obtained without contributing additional energy.

It does not request ignition of the generator.

Ask your installer for confirmation.

The heating starts up even though the ambient

temperature is greater than the set point

temperature:

Your installer has selected a form of regulation

known as PID which anticipates a drop in the

ambient temperature as a function of its evolution

over the last few hours.

The thermostat estimates that the ambient tempe-

rature will be less than the setpoint temperature if it

does not contribute additional energy. It requests

ignition of the generator. 

Ask your installer for confirmation.

Correct Disposal

of This product

(Waste Electrical

& Electronic Equipment).

(Applicable in the European Union and

other European countries with separate

collection systems).

This marking shown on the product or its

literature indicates that it should not be dis-

posed with other household wasted at the

end of its working life. To prevent possible

harm  to  the  environment  or  human  health

from  uncontrolled  waste  disposal,  please

separate  this  from  other  types  of  wastes

and  recycle  it  responsibly  to  promote  the

sustainable reuse of material resources.

Household  users  should  contact  either

the retailer where they purchased this pro-

duct,  or  their  local  government  office,  for

details of where and how they can take this

item for environmentally safe recycling.

Business users should contact their sup-

plier and check the terms and conditions of

the purchase contract. This product should

not be mixed with other commercial wastes

of disposal.

Reviews: