hager EK520 User Instructions Download Page 2

2

Initial adjustment and updating

When the product is first used, the screen offers

the option to adjust the year, date and time, without

going into the parameter settings. 

or

Press key 

a

menu

to place the cursor under 

.

• The year flashes, press key 

e

+

the navigation

key to adjust the current year. Confirm using the

OK 

key.

• The year flashes, Now press key 

+

or 

-

Confirm using the 

OK 

key then proceed

in the same manner to select the day, hour and

minutes.

• 

AUTO

flashes. Press key 

e

+

to set the installa-

tion to switch automatically between summer

and winter time (

auto

) or not (

OF

f

). Confirm using

the 

OK 

key.

• 

24:H

flashes. Press key 

e

+

and select

the 12 hour or 24 hour time format.

Confirm using the 

OK 

key.

Automatic mode (auto)

Manual mode transforms your equipment into a

simple thermostat. It allows you to maintain a

constant temperature in your accommodation

(adjustable from +5 °C to +30 °C) and ignores the

available program profiles.

• Press key 

menu

to place the cursor under

auto

.

Key 

a

menu

allows you to return to auto mode

when the (holiday) program is running or a timed

restart is in progress.

Manual mode (manu)

Manual mode transforms your equipment into

a simple thermostat. It allows you to maintain

a constant temperature in your accommodation

(adjustable from +5 °C to +30 °C) and ignores the

available program profiles.

• Press key 

menu

to place the cursor under

manu

.

• Press key 

e

+

or 

-

to adjust the desired tempe-

rature.

Example: the desired temperature is at 22.5 °C 

and the ambient temperature is 20 °C. 

The heating-activated indicator 15 is illuminated.

Standby mode

The heating and/or air conditioning system can be

put on standby. The thermostat is live and protects

your installation if the temperature drops below 

5 °C (fixed non-modifiable instruction). It displays

the time, current day, ambient temperature and 

Off information.

• Press key 

a

menu

to place the cursor

under  .

OF

f

flashes.

• Confirm using the 

OK

key.

• Press key 

a

menu

to exit standby mode.

From air conditioning mode, standby mode 

represents a stop command and the ambient 

temperature is no longer regulated.

PA:1

- Default duration of the temporary override

This parameter allows you to input a default, restart time delay. Possible delay times are the following:

1 hour, 2 hours, 3 hours, 4 hours, 5 hours and 12 hours. The restart delay is set to 1 hour by default.

• 

PA:1

and  flash. Press key 

e

+

or 

-

to modify the restart delay.

Confirm using the 

OK 

key to pass to the next parameter.

PA:2

- Backlighting

Backlighting is activated (

ON

) by default. 

• Press key 

e

+

or 

-

to deactivate it (

OF

f

).

Confirm using the 

OK 

key key to pass to the next parameter.

PA:3

- Temperature calibration

This parameter lets you adjust the value displayed by the thermostat if you measure a different

ambient temperature to that which the thermostat measures.

• Press key 

e

+

or 

-

to modify the temperature within a range of +/-3 °C.

Confirm using the 

OK 

key to pass to the next parameter.

PA:4

- 2

nd

Comfort temperature level

This parameter allows you to select one 

or two 

Comfort temperature levels. It is only applicable

during programming of the free program (

P4

).

• Press key 

e

+

or 

-

to choose 

1

or 

2

.

Confirm using the 

OK 

key to pass to the next parameter. 

Parameter 

PA:4

is set to 1 single level of Comfort by default.

PA:5

- Heating/Air-con mode

This parameter allows you to put your installation into Heating mode (

H

), Air conditioning mode (

C

or reversible Heating/Air-con mode (

HC

) (the icon  

is displayed). 

• Press key 

e

+

or 

-

to select 

H

C

or 

HC

Confirm using the 

OK 

key to pass to the next parameter. 

Parameter 

PA:5

is set to heating 

H

) by default. 

In 

HC 

mode, care should be taken to switch the HP suitably for the chosen thermostat mode.

PA:6

- Degumming the pump

This parameter allows you to activate/deactivate the automatic start-up of the pump at midnight

everyday, in order to avoid its jamming during the summer.

• Press key 

e

+

or 

-

to activate (

ON

) or desactivate (

OF

f

).

Confirm using the 

OK 

key to pass to the next parameter. 

Parameter 

PA:6

6 is set to 

OF

f

by default.

PA:7

Type of heating regulation

This parameter lets you define the type of inertia of your heating installation. 

• Press key 

e

+

or 

-

to select :

On/OF

f

= On or off (default setting). The differential is less than 0.3°C (factory setting).

FA

S

= PID regulation for installations with rapid inertia (radiator). 

Minimum run time 1 minute (10% of the cycle time).

SL

o

= PID for installations with slow inertia (underfloor heating). 

Minimum run time 2 minutes (10% of the cycle time).

• Confirm using the 

OK

key to pass to the next parameter.

In On/Off regulation, only the anticipation function is available, see 

PA:9

In PID regulation, the optimisation and anticipation functions are available, see 

PA:9

.

PA:8

- T

ype of regulation for air conditioning

As 

PA:7

but 

FA

S

used for convector fan and 

SL

o

for underfloor cooling.

PA:9

- Optimisation and anticipation

This parameter allows you to activate an optimisation or anticipation function which is deactivated

(

OF

f

) by default.

The optimisation function is only available with PID regulation, see 

PA:7

or 

PA:8

The anticipation function is available with on/off and PID regulation.

Optimisation

: he thermostat automatically estimates the time required

to reach the Comfort temperature and adjusts the switch-on time of the

heating so that the desired temperature is attained at the desired time.

A period of around 10 days is necessary to train the installation because

it depends on the type of inertia of your heating. 

Note

: only 

P1

o

benefits from the optimisation function. 

• Press key 

e

+

to activate (

AUT

) the optimisation function. 

Confirm using the 

OK

key to pass to the next parameter.

16 °C

18 °C

20 °C

7 h

x

16 °C

18 °C

20 °C

6 h

2H

H

(calcul automatique) 

16 °C

18 °C

20 °C

7 h

x

H

(automatische 
Berechnung)

FR

DE

16 °C

18 °C

20 °C

7 h

x

H

(automatic calculation)

GB

16 °C

18 °C

20 °C

7 h

x

H

(automatische 
berekening)

NL

16 °C

18 °C

20 °C

7 h

x

H

(calcolo automatico) 

16 °C

18 °C

20 °C

7 h

x

H

(cálculo automático)

IT

ES

16 °C

18 °C

20 °C

7 h

x

H

(αυτόματος 

υπολογισμός)

GR

16 °C

18 °C

20 °C

7 h

x

H

(obliczenia 
automatyczne)

PL

16 °C

18 °C

20 °C

7 h

x

H

(automaattinen
laskenta)

FI

In reversible heating/air-conditioning mode (select 

HC

for parameter

PA:5

); it is possible to select a different mode of regulation for each 

system.

The heating may be configured as on/off and the air conditioning as PID

regulated. In this case, the optimisation function and program 

P1

o

can

only be applied during PID regulated air-conditioning.

Anticipation

: this function allows the Comfort 

or Comfort 2 

temperature from the personalised program (

P4

) to be applied, in

advance, for a configurable period of 1, 2 or 3 hours.

Note

: only 

P4a

benefits from the anticipation function.

• Press key 

e

+

to select the duration (

1H

2H

ou 

3H

) of anticipation

desired, (e.g. anticipation of 2 hours).

Confirm using the 

OK

key to pass to the next parameter.

16 °C

18 °C

20 °C

7 h

x

16 °C

18 °C

20 °C

6 h

2H

H

(calcul automatique) 

16 °C

18 °C

20 °C

7 h

x

H

(automatische 
Berechnung)

FR

DE

16 °C

18 °C

20 °C

7 h

x

H

(automatic calculation)

GB

16 °C

18 °C

20 °C

7 h

x

H

(automatische 
berekening)

NL

16 °C

18 °C

20 °C

7 h

x

H

(calcolo automatico) 

16 °C

18 °C

20 °C

7 h

x

H

(cálculo automático)

IT

ES

16 °C

18 °C

20 °C

7 h

x

H

(αυτόματος 

υπολογισμός)

GR

16 °C

18 °C

20 °C

7 h

x

H

(obliczenia 
automatyczne)

PL

16 °C

18 °C

20 °C

7 h

x

H

(automaattinen
laskenta)

FI

Installer parameters

To access all the parameters (from

PA:1

to 

PA:12

), press key 

a

menu

to place the cursor under 

and

then give one long press (>5s) on 

OK

.

To only access parameters from (

PA:1

to 

PA:4

), press key 

a

menu

to place the cursor under 

and

confirm using the 

OK 

key.