background image

1

6L

E

00

15

24

A

EK520

Product description

a

Context key for 

menu 

access

Context key for mode access holidays 
Context key to access the temporary
override 

d

Confirmation key 

OK

e

Adjustment keys 

+

and 

-

f

Indicator for days of the week

g

Automatic mode/manual mode
(thermostat without program) 

h

Temperature set-points adjustment

i

Standby 

j

Heating/Air-con selector 

k

Programming/program selection

l

ATime and date adjustment

m

Adjustment of settings

Ambient temperature

o

Heating or air conditioning indicator 

p

Current mode (heating or air conditioning) 

q

Current setting (

,

, ,

)

r

Temperature of current setting

s

Telephonic remote-control 

t

Battery use indicator 

Profile of today's program

Current time

ok

+

§

Programmable ambient

thermostat, 2 wire, weekly, battery

powered

User instructions

This programmable ambient thermostat has been designed to bring you comfort and energy economy.

It allows you to program and regulate your heating system at 4 temperature levels:

- Comfort 

: this is the temperature you desire during the hours you are present.

- Comfort 2 

: 2nd temperature level that you desire during the time you are present.

- Eco  : this is the temperature you desire during short absences or at night.

- Frost protection  : this is the guaranteed minimum temperature during your prolonged absences. 

It protects your accommodation against the dangers of frost.

It also enables you to program and regulate your air conditioning at 2 temperature levels:

- Comfort 

: this is the temperature you desire during the hours you are present.

- Eco  : this is the temperature you desire during short absences or at night.

ok

+

Electrical installation and connections

To guarantee its ambient temperature regulation

function, the thermostat should be installed at least

1.3 m above the ground, on an interior wall and

away from direct sunlight or any heat source such

as a television, lamp, radiator, draft, chimney etc. Fix

the thermostat onto the flush-mounted casing or in

the slot without a casing intended for this purpose.

For optimum quality temperature regulation, seal

the flush-mounted casing or the electrical duct. 

1. Separate the product from the wall-mounted

base, by pushing on the button located under

the base.

2. Open the flap with the help of a screwdriver and

attach the wall-mounted base using the screws.

3. Next, pass the electrical cables into the holes

intended for this purpose.

4. Connect the product according to the wiring dia-

gram opposite.

5. Reclose the flap

Installation must be carried out by 

professional in accordance with the 

standards in force.

TOP

+

ok

 

 

TOP

TOP

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

telephonic remote-control
(ref. 61123, 61124)

 

 

 

 

 

 

   

   

 

 

   

   

 

 

   

   

 

 

   

   

 

 

   

   

 

 

   

   

 

N

 

L

1 2 3

2

 7

6 A

 

   

   

 

   

 

 

 

 

 

   

 

 

 

 

 

 

 

 

   

   

 

 

 

   

 

 

   

 

 

 

   

   

 

 

 

   

 

 

 

 

 

1 2 3

2

 7

telephonic remote-control
(ref. 61123, 61124)

   

 

 

 

 

   

 

 

 

 

 

   

   

   

   

   

   

   

   

   

   

   

   

2

 7

1 2 3

   

   

 

 

   

 

 

 

input
from remote ambient thermostat

 

 

 

 

 

 

 

 

 

 

 

Connection of the thermostat to a thermostat

input on the boiler

Connection of the thermostat to the thermostat

input of a reversible or irreversible heat pump

(HP)

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

telephonic remote-control
(ref. 61123, 61124)

 

 

 

 

 

 

 

 

input
from remote ambient thermostat

 

 

 

 

 

 

 

 

 

   

   

   

   

   

   

   

   

 

 

   

   

1 2 3

2

 7

   

   

   

   

Connection of a heating or air conditioning

circulator

6. Insert the batteries into the thermostat.

7. Clip the front face onto the wall-mounted base.

Reset