6E 6133.b
A warranty period of 24 months is offered on hager products,
from date of manufacture, relating to any material of manu-
facturing defect. If any product is found to be defective it must
be returned via the installer and supplier (wholesaler). The
warranty is withdrawn if :
- after inspection by hager quality control dept the device is
found to have been installed in a manner which is contrary to
IEE wiring regulations and accepted practice within the industry
at the time of installation.
- the procedure for the return of goods has not been followed.
Explanation of defect must be included when returning
goods.
Warranty
GB
The override duration is adjustable from 1 hour to
47 hours by steps of 1 hour then from 2 to 99 days
by steps of 1 day.
The temporary override time period can be different
on each channel.
1. Press the key
repeatedly to place the
cursor below
for channel A.
2. Input with keys “
+
” or. “
-
” the override
duration.
3. Select the state of the output with key
“
on/off
”.
4. Confirm with “
enter
”.
1. Press the key
repeatedly to place the
cursor below
for channel A, B, C or D.
2. Press “
clear
” to cancel the timed override.
3. Press the key
repeatedly to place the
cursor below “
auto
” and switch back to
automatic mode.
Timed override :
reset
7
6
1
2
3
4
5
–
enter
on/off
clear
on
auto
off
Prog Auto
+
ON
B
A
C
D
A
B
C
D
reset
7
6
1
2
3
4
5
–
enter
on/off
clear
on
auto
off
Prog Auto
+
OFF
B
A
C
D
A
B
C
D
To cancel the timed override on channels A, B, C
or D :
Temporary override on channel A.
1. Press the key
repeatedly to place the
cursor below
for channels B, C or D.
2. Use the same process as for channel A.
3. Press the key
repeatedly to place the
cursor below “
auto
” and switch back to
automatic mode.
The channel cursor flashes to indicate that a timed
override has been programmed. After the duration,
the program will resume its
normal course.
Temporary override on channels B, C or D.
3 4 5 6
2
1
L
N
EG 470
14 15
7 8 9
18 19
A
A,B,C,D
C
11 12 13
B
10
D
16 17
OFF
20
Technical specifications :
Electrical characteristics :
- supply voltage : 230V ±15% 50/60 Hz
- outputs : 4 changeovers contact
µ 16 A - 250 V AC1
µ 3 A - 250 V cos
= 0.6
1000 W incandescent lighting
- power consumption : 20 VA
- protection degree : IP20
- insulation class : II
Functional characteristics :
- accuracy : ± 1sec. / day at 20 °C
- operating reserve : lithium battery,
total of five years.
Environment :
Operating temperature : -10 to +50 °C
Storage temperature :
-20 to +60 °C
Connection tunnel terminals :
flexible : 0,5 to 2,5 mm
2
rigid : 0,5 to 4 mm
2
Dimensions : 5 modules
Electrical connections :
To reset the time switch :
Press “
reset
“ to clear the program.
External input for off override :
This external input lets you simultaneously force off
all 4 channels.
To activate this input, just connect the 230V phase
supply to terminal 20.
This input has priority, even if all 4 channels were
manually forced as on.