– 20 –
1. Connect signal from source to CH B input.
2. Biamp/Stereo switch not active (Stereo/Mono switch
overrides this switch when in mono/70V/100V mode).
3. Move Stereo/Mono switch to 100V mode.
4. Select 100V load, both channels.
5. Connect parallel array of 100V transformer-equipped
speakers across the red terminals of the 5-way binding
posts. (1200W – SR2600, 600W – SR2300)
6. CH B input sensitivity controls 100V mono output level.
Amplifier will clip at 100Vrms level.
Power
70V
4
Ω
Load
2
Ω
100V
8
Ω
70V
4
Ω
2
Ω
100V
8
Ω
BIAMP STEREO
CH A
IN
—
+
300W
2
Ω
– 8
Ω
Mono,70V,100V
CH B
IN
CH A
OUT
CH B
OUT
+
—
300W
2
Ω
– 8
Ω
—
+
600W
For 70V, 100V, or Mono
• Use CH B input
• Load across RED
terminals
• Set load switches to one
half load impedance
A Division of
Rockford Corp.
Tempe, AZ 85281
Made in the U.S.A.
S R 2 3 0 0
300 W Stereo, 2
Ω
– 8
Ω
600W Mono, 70V,100V
(Mono)
250W
100V-120V~
50-60Hz
250V T7A
Chassis
Float
Audio GND
3
2
1
+
–
+
–
Attention: Utiliser un fusible
de rechange de même type.
CAUTION: For continued
protection from risk of fire,
replace only with same type
and rating of fuse.
4
Ω
– 16
Ω
100 Volt
Transformer
100 Volt
Transformer
Parallel Array
etc.
100V
70V
100V
70V
SR2300
SR2600
Power
70V
4
Ω
Load
2
Ω
100V
8
Ω
70V
4
Ω
2
Ω
100V
8
Ω
BIAMP STEREO
CH A
IN
—
+
300W
2
Ω
– 8
Ω
Mono,70V,100V
CH B
IN
CH A
OUT
CH B
OUT
+
—
300W
2
Ω
– 8
Ω
—
+
600W
For 70V, 100V, or Mono
• Use CH B input
• Load across RED
terminals
• Set load switches to one
half load impedance
A Division of
Rockford Corp.
Tempe, AZ 85281
Made in the U.S.A.
S R 2 3 0 0
300 W Stereo, 2
Ω
– 8
Ω
600W Mono, 70V,100V
(Mono)
250W
100V-120V~
50-60Hz
250V T7A
Chassis
Float
Audio GND
3
2
1
+
–
+
–
Attention: Utiliser un fusible
de rechange de même type.
CAUTION: For continued
protection from risk of fire,
replace only with same type
and rating of fuse.
4
Ω
– 16
Ω
70 Volt
Transformer
70 Volt
Transformer
Parallel Array
etc.
70 Volt
Transformer
70 Volt
Transformer
etc.
100V
70V
SR2600
1. Connect signal from source to both CH A and CH B inputs.
2. Move Biamp/Stereo switch to Stereo mode.
3. Move Stereo/Mono switch to Stereo mode.
4. Select 8
Ω
speaker load for each channel.
5. Connect parallel array of 70V transformer-equipped
speakers (up to 600W per channel) to 5-way binding
posts.
6. Adjust CH A and CH B level controls independently.
100V MONO MODE (SR2300/SR2600)
70V STEREO MODE (SR2600 ONLY)
Summary of Contents for SR2300
Page 1: ...Owner s Manual Owner s Manual SR2300 SR2600 SR2300 SR2600...
Page 2: ......
Page 26: ...24 Schematic Diagrams PC 2460 e sch 1 EMI FILTER...
Page 27: ...25 C600_maualB sch 4 BRIDGE RECTIFIER...
Page 28: ...26 AMPLIFIER...
Page 29: ...27 C600_maualB sch 1...
Page 30: ...28 PROTECTION...
Page 31: ...C600_maualB sch 2 29...
Page 32: ...30 HIGH VOLTAGE CONTROL...
Page 33: ...31 C600_maualB sch 3...
Page 34: ...32 HOUSEKEEPING CONTROL...
Page 35: ...33 C600_maualB sch 6...
Page 36: ...34 INPUT...
Page 37: ...35 C600_maualB sch 8...
Page 38: ...36 POWER...
Page 39: ...37 C600_maualB sch 5...