background image

– 1 –

The Hafler TA1100 and TA1600 are two channel, two rack height, convection-cooled, MOSFET power amplifiers suitable
for use in the most demanding applications of critical listening and instrument amplification. These amplifiers offer the
same outstanding sonic quality and reliability that has contributed to Hafler’s enviable reputation within professional
recording studios and broadcast facilities all over the world.

This manual contains information on using the TA1100 and TA1600 amplifiers. It is organized into two main sections.
“Installation” covers the location and connection of the amplifier in the system. Like many precision components, careful
attention to the initial setup can yield dividends in higher performance and trouble-free use. “Operation” covers the con-
trols and features of the amplifiers and how to use them to get the best effect. 

The circuitry used in the TA 1600 is the latest refinement of our patented trans•

nova (TRANSconductance NOdal Voltage

Amplifier, US Patent 4,467,288) circuit. It has been proven to offer sound quality to satisfy the most analytic audiophile or
the most demanding professional. The natural sound and realistic reproduction have made trans•

nova amplifiers preferred

in many critical installations. Since our pioneering use of MOSFETs in the DH-200 amplifier, they have proven extremely
fault tolerant even in abusive situations. This sturdiness enables the amplifier to drive reactive speaker loads without the
performance and sound penalties imposed by elaborate protection schemes.

The TA1100 trans•

ana circuitry has been very successful in bringing new levels of clarity and intelligibility to many broad-

cast facilities and headphone monitoring installations. Even at low power levels, the trans•

ana MOSFET amplifier circuit

imitates the accuracy and warmth of it’s bigger brother, the TA1600 trans•

nova.

Specialized circuits in both amplifiers prevent damage to the amplifiers and speakers, without affecting the audio signal. A
soft start circuit prevents sending potentially destructive turn-on and turn-off transients to the speakers. A thermal sensing
network monitors the heatsink and transformer temperature, and shuts down the amplifier to protect from excessive operat-
ing heat. The need for internal fuses has been eliminated; a sensing circuit monitors the output and shuts down operation
when it detects a short in the output load.

The front panel has controls for input level adjustment. In addition, LED indicators give a visual representation of the oper-
ating status of each channel. Any type of fault - whether it is clipping, short protection, or thermal standby - will be indicat-
ed with a red LED.

Hafler manufactures additional Professional and Home Theatre amplifiers and monitors that offer an extreme level of per-
formance and advanced technology. Visit our website at www.hafler.com for more information.

Introduction

Summary of Contents for 1600

Page 1: ......

Page 2: ... x 3 1 2 H 2 rack space 48cm x 25cm x 8 9cm Net Weight 22 lbs 9 98kg TA 1100 Power Rating 1kHz 0 1 THD 50 wpc into 4Ω 40 wpc into 8Ω Frequency Response 0 1dB 20Hz to 20kHz 0 3dB 1 0Hz to 100kHz Slew Rate 20V µs Input Sensitivity for rated output power Unbalanced 0 640V RMS 8Ω 0 510V 4Ω Balanced 0 320V 8Ω 0 250V 4Ω per phase Power Consumption 40VA quiescent TA 1600 Power Rating 1kHz 0 1 THD 75 wpc ...

Page 3: ...ble rating to deliver the required total current for safe operation of all connected equipment Furthermore extension cords or power strips must provide the same three wire grounded connection It is impor tant that the blades of the equipment s plug be able to fully insert into the mating receptacle Never remove the round grounding pin on the plug in an attempt to mate to a two wire unground ed rec...

Page 4: ...de tres hiles Es importante que el enchufe se pueda introducir com pletamente en el receptáculo Nunca remeva el pin de ater ramiento en un intento por conectar el cable en un receptáculo de dos hilos no aterrado use un adaptador de aterramiento que esté adecuadamente conectado a un punto de tierra 11 PERIODOS SIN USO Durante períodos prolongados sin uso del equipo el cable de corriente debe ser de...

Page 5: ...DUCTION 1 DESIGN FEATURES 2 INSTALLATION Location 3 AC Line 3 Input 3 Output 3 Hum 3 OPERATION Power Switch 5 Level Controls 5 TA 1100 5 TA 1600 Short Circuit Protection 5 Warm Up 5 Cleaning and Maintenance 5 SERVICE POLICY LIMITED WARRANTY 6 Table of Contents ...

Page 6: ...t tolerant even in abusive situations This sturdiness enables the amplifier to drive reactive speaker loads without the performance and sound penalties imposed by elaborate protection schemes The TA1100 trans ana circuitry has been very successful in bringing new levels of clarity and intelligibility to many broad cast facilities and headphone monitoring installations Even at low power levels the ...

Page 7: ...ntrol 2 Clip Thermal Protect LED 3 Power switch 4 Headphone jack 1 Balanced 1 4 input 2 Unbalanced RCA input 3 IEC line cord connector 4 Line fuse compartment 5 1 4 mono speaker output 6 Spring clip output 1 2 4 3 2 1 1 2 4 3 5 6 5 2 1 ...

Page 8: ... is detected If this fuse blows replace it with the same type and rating fuse only The correct replacement fuse value is printed on the rear panel of the amplifier If the new fuse blows this is an indication of a fault with the amplifier Servicing should be performed only by a qualified technician INPUT The input jacks on the back of the amplifier will accept either 1 4 balanced 1 4 unbalanced or ...

Page 9: ...ower distribution block or preamp switched outlet When doing so make sure the switch is rated for the current required by the amplifier LEVEL SETUP The input sensitivity for each channel can be adjusted individually using the Level Controls on the front panel Set up the amplifier Level Controls such that the amplifier clipping LED s light occasionally when the source unit level control is turned u...

Page 10: ...aner If the amplifier is located in a particularly dusty environment cleaning the inside with compressed air or vacuuming every 18 to 24 months is sufficient Troubleshooting No Sound Adjust the system headroom First turn the source unit level control up to 3 4 maximum Next turn the amplifier level controls down until the clip LED activates occasional only during peak audio events SYMPTOM DIAGNOSIS...

Page 11: ...y product purchased outside the United States please contact your local dealer 4 Shipping charges to get the unit to Hafler 5 Any product which has had the serial number defaced altered or removed Limit on Implied Warranties Any implied warranties including warranties of fitness for use and merchantability are limited in duration to the period of the express warranty set forth above Some states do...

Page 12: ... HAFLER A DIVISION OF ROCKFORD CORPROATION 546 SOUTH ROCKFORD DRIVE TEMPE ARIZONA 85281 U S A 480 967 3565 1 888 HAFLER1 WWW HAFLER COM M J T 6 00 MADE IN TAIWAN ...