background image

ii

NOTICE - IMPORTANT SAFETY INFORMATION

C A U T I O N

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING:

  TO PREVENT FIRE OR SHOCK HAZARD 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.

!

1.

Read Instructions
All the safety and operating instructions of your Hafler equip-
ment should be read before power is applied to the equipment.

2.

Retain Owner's Manual
These safety and operating instructions should be retained for
future reference.

3.

HEED WARNINGS
All warnings on the equipment and in the operating instruc-
tions are important and should be followed.

4.

FOLLOW INSTRUCTIONS
All operating and use instructions are important and should be
followed.

5.

HEAT
The equipment should be kept away from areas of high tem-
perature, i.e., heater vents, radiators, stoves/ovens, fireplaces,
etc.

6.

VENTILATION
The equipment should be used in an area suitable for proper
ventilation.  Care should be taken not to impede airflow in and
around the cabinet.  Do not mount on a carpeted shelf or in a
sealed enclosure.  Allow for proper clearance above the equip-
ment.

7.

WATER AND MOISTURE
The equipment should not be used in or around water, such as
a bathtub, sink, or swimming area.  Also, the equipment should
not be used in areas prone to flooding, such as a basement.

8.

POWER SOURCES
The equipment should be connected only to a power source of
the same voltage and frequency as that listed on the rear panel
above the power cord entry point.

9.

POWER CORD PROTECTION
Power cords should be arranged so they do not interfere with
the movement of objects in the room: people, fan blades, util-
ity carts, etc.  Also, care should be taken that the cord is not
pinched or cut, and placed so it is not in danger of being
pinched or cut, as in under a rug, around a tight corner, etc.

10. POWER CORD GROUNDING

The power supply cord is of a three wire grounded type,
designed to reduce the risk of electric shock sustained from a
live cabinet.  It is assumed to be of suitable length for most uses
of the equipment.  The use of extension cords and power strips
is discouraged unless they are of suitable rating to deliver the
required total current for safe operation of all connected

equipment.  Furthermore, extension cords or power strips must
provide the same three wire grounded connection.  It is impor-
tant that the blades of the equipment’s plug be able to fully insert
into the mating receptacle.  Never remove the round grounding
pin on the plug in an attempt to mate to a two wire unground-
ed receptacle: 
use a grounding adapter with the grounding tab or
wire suitably connected to earth ground.

11. NON-USE PERIODS

During periods of extended non-use, the power cord should be
unplugged from the power source.

12. CLEANING

The equipment should be cleaned only as detailed in the operat-
ing instructions.

13. OBJECT AND LIQUID ENTRY

Care should be taken so that objects and/or liquids, such as
cleaning fluids or beverages, are not spilled into the enclosure of
the equipment.

14. DAMAGE REQUIRING SERVICE

Hafler equipment should be serviced by qualified service per-
sonnel when:

A. The power supply cord or plug has been damaged, or

B. Objects have fallen, or liquid has been spilled into the 
equipment, or

C. The equipment has been exposed to rain, or

D. The equipment does not appear to operate normally or 
exhibits a marked change in performance, or

E. The equipment has been dropped, or the enclosure has 
been damaged.

15. SERVICING

The user should not attempt to service the equipment beyond

that which is described in the operating instructions.  All other serv-
ice should be referred to qualified service personnel.

16. CARTS AND STANDS

The equipment should be used with carts or stands only of 
sufficient strength and stability for the use intended.

An equipment and cart combination should be moved with 
care. Quick stops and starts, excessive force, and uneven sur
faces.

The lightning flash with arrowhead symbol within an equilateral triangle
is intended to alert the user to the presence of uninsulated "dangerous volt-
age" within the product's enclosure, that may be of sufficient magnitude
to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert
the user of the presence of important operating and maintenance (servic-
ing) instructions in the literature accompanying the appliance.

Summary of Contents for 1600

Page 1: ......

Page 2: ... x 3 1 2 H 2 rack space 48cm x 25cm x 8 9cm Net Weight 22 lbs 9 98kg TA 1100 Power Rating 1kHz 0 1 THD 50 wpc into 4Ω 40 wpc into 8Ω Frequency Response 0 1dB 20Hz to 20kHz 0 3dB 1 0Hz to 100kHz Slew Rate 20V µs Input Sensitivity for rated output power Unbalanced 0 640V RMS 8Ω 0 510V 4Ω Balanced 0 320V 8Ω 0 250V 4Ω per phase Power Consumption 40VA quiescent TA 1600 Power Rating 1kHz 0 1 THD 75 wpc ...

Page 3: ...ble rating to deliver the required total current for safe operation of all connected equipment Furthermore extension cords or power strips must provide the same three wire grounded connection It is impor tant that the blades of the equipment s plug be able to fully insert into the mating receptacle Never remove the round grounding pin on the plug in an attempt to mate to a two wire unground ed rec...

Page 4: ...de tres hiles Es importante que el enchufe se pueda introducir com pletamente en el receptáculo Nunca remeva el pin de ater ramiento en un intento por conectar el cable en un receptáculo de dos hilos no aterrado use un adaptador de aterramiento que esté adecuadamente conectado a un punto de tierra 11 PERIODOS SIN USO Durante períodos prolongados sin uso del equipo el cable de corriente debe ser de...

Page 5: ...DUCTION 1 DESIGN FEATURES 2 INSTALLATION Location 3 AC Line 3 Input 3 Output 3 Hum 3 OPERATION Power Switch 5 Level Controls 5 TA 1100 5 TA 1600 Short Circuit Protection 5 Warm Up 5 Cleaning and Maintenance 5 SERVICE POLICY LIMITED WARRANTY 6 Table of Contents ...

Page 6: ...t tolerant even in abusive situations This sturdiness enables the amplifier to drive reactive speaker loads without the performance and sound penalties imposed by elaborate protection schemes The TA1100 trans ana circuitry has been very successful in bringing new levels of clarity and intelligibility to many broad cast facilities and headphone monitoring installations Even at low power levels the ...

Page 7: ...ntrol 2 Clip Thermal Protect LED 3 Power switch 4 Headphone jack 1 Balanced 1 4 input 2 Unbalanced RCA input 3 IEC line cord connector 4 Line fuse compartment 5 1 4 mono speaker output 6 Spring clip output 1 2 4 3 2 1 1 2 4 3 5 6 5 2 1 ...

Page 8: ... is detected If this fuse blows replace it with the same type and rating fuse only The correct replacement fuse value is printed on the rear panel of the amplifier If the new fuse blows this is an indication of a fault with the amplifier Servicing should be performed only by a qualified technician INPUT The input jacks on the back of the amplifier will accept either 1 4 balanced 1 4 unbalanced or ...

Page 9: ...ower distribution block or preamp switched outlet When doing so make sure the switch is rated for the current required by the amplifier LEVEL SETUP The input sensitivity for each channel can be adjusted individually using the Level Controls on the front panel Set up the amplifier Level Controls such that the amplifier clipping LED s light occasionally when the source unit level control is turned u...

Page 10: ...aner If the amplifier is located in a particularly dusty environment cleaning the inside with compressed air or vacuuming every 18 to 24 months is sufficient Troubleshooting No Sound Adjust the system headroom First turn the source unit level control up to 3 4 maximum Next turn the amplifier level controls down until the clip LED activates occasional only during peak audio events SYMPTOM DIAGNOSIS...

Page 11: ...y product purchased outside the United States please contact your local dealer 4 Shipping charges to get the unit to Hafler 5 Any product which has had the serial number defaced altered or removed Limit on Implied Warranties Any implied warranties including warranties of fitness for use and merchantability are limited in duration to the period of the express warranty set forth above Some states do...

Page 12: ... HAFLER A DIVISION OF ROCKFORD CORPROATION 546 SOUTH ROCKFORD DRIVE TEMPE ARIZONA 85281 U S A 480 967 3565 1 888 HAFLER1 WWW HAFLER COM M J T 6 00 MADE IN TAIWAN ...

Reviews: