background image

Function description

24

LED

Status

Meaning

LED1_1

to LED1_8

yellow

relay actuated

LED1

green

communication of interface is OK

red

communication not possible

orange

communication OK, data missing

LED2

blue

module not initialised

rapid flashing in green

reset in progress

rapid flashing in red x times
(after reset)

display of bus address,
e.g. 3x flashing = address 3

Summary of Contents for WTC 200

Page 1: ...Version 12 08 2015 MOUNTING INSTRUCTIONS WTC 200 Wall Terminal Controller WRU 200 Wall Reader Unit WTX 200 WTX 201 Extension Modules Access control with experience...

Page 2: ...document even extracts thereof and replication of the design is forbidden Exclusion of liability H fele GmbH Co KG compiles the contents of this document with the utmost care and ensures that they ar...

Page 3: ...ystem in a location where they are accessible to the personnel at all times The personnel must have carefully read and understood these instructions before starting any work A basic prerequisite for s...

Page 4: ...onal 23 3 Assembly and installation 25 3 1 Installation location requirements 25 3 2 Assembly and installation of controller and power supply on top hat rail 25 3 3 Reader assembly and installation 27...

Page 5: ...h optional separate power supply Fig 1 Controller in sheet steel housing with integrated power supply Fig The WTX 200 I O board additional module is also optionally available with which the connecting...

Page 6: ...t avoided WARNING This combination of symbol and signal word indicates a potentially dangerous situation which could lead to death or serious injuries if it is not avoided CAUTION This combination of...

Page 7: ...al words that have been described above are used Example 1 Loosen screw 2 CAUTION Risk of trapping cable at cover Carefully close cover 3 Tighten screw Special safety instructions The following symbol...

Page 8: ...of use The WTC 200 controller the WRU 200 reader and the additional modules WTX 200 I O module WTX 201 8 way relay module are exclusively intended for use in an access control system The correct purp...

Page 9: ...inets bearing this marking Crossed out waste bin This picture indicates that the respective component may not be disposed of with the domestic waste Do not touch Parts may be destroyed if they are tou...

Page 10: ...ty for protecting the user the personnel or third parties during operation Operator responsibilities The access control system is used in the commercial area The operator of the access control system...

Page 11: ...recognise and avoid potential dangers independently The electrical expert is specially trained for the working environment in which he works and is aware of the relevant standards and regulations Basi...

Page 12: ...into the environment suitable measures must be taken immediately In case of doubt the responsible local authority must be notified about the damage and consulted about suitable measures to be taken Th...

Page 13: ...2 2 1 Installation version 1 One door with one reader on page 14 One door with two readers internal and external door signalling contact and door strike Chapter 2 2 2 Installation version 2 Two doors...

Page 14: ...2 1 Installation version 1 One door with one reader status contact electric strike accustic indicator Fig 2a Cable diagram for door with reader controller door open pushbutton accoustic indicator str...

Page 15: ...ption 15 2 2 2 Installation version 2 Two doors one reader each with strike Fig 4 Installation version 2 Fig 3aCable diagram fortwo doors with one reader each Fig 3b Wiring diagram fortwo doors with o...

Page 16: ...Function description 16 2 2 3 Installation version 3 One door with two readers e g interior and exterior Fig 4a Cable diagram one door two readers3 Fig 4b Wiring diagram one door two readers...

Page 17: ...scription 17 2 2 4 Installation version 4 Four doors each with a reader Fig 5a Cable diagram door 1 and door 2 Fig 5b Cable diagram door 3 and door 4 Installing the additional module WTX 200 I O board...

Page 18: ...Function description 18 Fig 5c Wiring diagram door 1 door 2 door 3 and door 4...

Page 19: ...and 8 11 Pins for attaching screw clamps 8 RS 485 connections clamp 8 9 10 9 Relay outputs clamp 6 and 7 10 Analogue digital inputs clamp 2 5 11 External power supply connection clamp 1 LEDs Status a...

Page 20: ...NO and C Analogue digital inputs 2 5 e g connection of door signalling contacts RJ45 network connection Network connection for communicating with the server or the configuration software 2 3 2 WRU 200...

Page 21: ...nsion WTX 200 I O board optional Fig 9 I O board additional module The number of connections to the controller can be extended using the WTX 200 I O board Six additional connections to the controller...

Page 22: ...oard fitted to controller The WTX 200 I O board Fig Fehler Verweisquelle konnte nicht gefunden werden 1 is fitted to the controller with spacers and fits beneath the cover Chapter 0 Installing the add...

Page 23: ...e added to the WTC 200 controller using the WTX 201 8 way relay module The control inputs of elevators for example can be connected via the relay outputs The 8 way relay module also has an analogue di...

Page 24: ...d LED1 green communication of interface is OK red communication not possible orange communication OK data missing LED2 blue module not initialised rapid flashing in green reset in progress rapid flash...

Page 25: ...te power circuit The voltage of the customer provided power supply must fulfil the requirements of the power supply that is used See power supply operating instructions for more information The cable...

Page 26: ...ller Table Use and functionality of connections and interfaces on page 20 Chapter 0 Reader assembly and installation on page 27 Typical installation versions Chapter 2 2 Installation versions on page...

Page 27: ...ng cable between the controller and the switch box has already been routed and connected to the controller 1 Disconnect power supply of controller Fig 14 Reader frame 2 Screw frame of reader to pre in...

Page 28: ...ew cover back onto rear of reader Fig Fehler Verweisquelle konnte nicht gefunden werden 1 When doing this lead out the cables at the padded cable ducts at the side Fig Fehler Verweisquelle konnte nich...

Page 29: ...rmation examples Set up and pin assignments for WTX 200 I O board on page 32 Assignment options of the additional connecting facilities pins 1 6 on page 33 Example Use of additional module 4 for addit...

Page 30: ...controller Do not press the module down using force The spacers at the additional module must fit exactly into the slots at the controller Fig 20 The header strips at the additional module Fig Fehler...

Page 31: ...Assembly and installation 31 Fig 23 I O board additional module fitted to controller The additional connecting facilities connections 1 6 are now available...

Page 32: ...g on how the jumpers are fitted to the WTX 200 I O board the additional connections have a dif ferent function The following wiring diagram the table and the examples show how the individual connectio...

Page 33: ...1 6 Pin 3 relay outputs NO and C 2 relay outputs NO and C 1 input 1 relay output NO and C 3 inputs 2 relay outputs NO C and NC 1 relay output NO C and NC 2 inputs 1 NO 1 NO 1 NO 1 NO 1 NO 1 2 C 1 C 1...

Page 34: ...the additional connecting facilities connection 1 6 are to be used for door signalling contacts for example the jumpers must be set as shown in Fig Fehler Verweisquelle konnte nicht gefunden werden 1...

Page 35: ...ing facilities connection 1 6 are to be used for 2 door strikes and 1 door signalling contact for example the jumpers must be set as shown in Fig Fehler Verweisquelle konnte nicht gefunden werden 1 As...

Page 36: ...d LEDs 10 11 12 13 LEDs of the RS 485 interfaces not flashing LEDs 1 2 4 Network connection LED illuminated yellow LED at network connection Configuration and initial start up The system configuration...

Page 37: ...Assembly and installation 37 LEDs on the WTC 200 Fig 27 Overview of LEDs at the WTC 200 controller 1 17 A LED 1 to LED 17 Network connection...

Page 38: ...too much en ergy Supply end consumer with energy using own on site energy source LED 3 LED 5 not active LED 6 rapid flashing in red no valid software in controller Copy valid software to Micro SD car...

Page 39: ...or power consumption too high fuse PTC S1 has tripped LED 16 illuminated in green operating voltage 3 3 V is OK LED 17 illuminated in green operating voltage 5 V is OK LEDs at network connection RJ45...

Page 40: ......

Page 41: ...power supply discharge residual energy Disconnect interconnecting cable between the components 4 3 Disposal NOTE Danger to environment from incorrect disposal The environment could be put at risk if...

Page 42: ......

Page 43: ...er storage temperature 25 to 70 C Separate power supply storage temperature 10 to 60 C Sheet steel housing with power supply storage temperature 0 to 55 C Relative humidity max 90 non condensing The p...

Page 44: ...ion Value Unit Voltage 12 24 V DC Tolerance 15 Current consumption maximum 0 125 A Power consumption maximum 1 5 W Fuse protection 1 A Ambient conditions during operation Specification Value Unit Temp...

Page 45: ...ee separate installation instructions of plastic housing with integrated power supply Plastic housing dimension sheet bigger wall housing on request Fig 29 Dimension sheet for plastic housing Dimensio...

Page 46: ...put 90 265 V AC Voltage output 13 8 V DC Current consumption maximum 3 A Power consumption maximum 750 W Fuse protection 3 A Ambient conditions during operation Specification Value Unit Temperature ra...

Page 47: ...eight with frame 85 g Width 81 mm Height 81 mm Depth 15 35 mm Connection and rating values Specification Value Unit Voltage 9 14 V DC Current consumption maximum at 12 V 0 3 A Power consumption maximu...

Page 48: ...ension sheet Fig 32 Dimension sheet for 8 way relay module Dimensions and weight Specification Value Unit Weight 180 g Length 85 mm Width 128 mm Height 65 mm Connection and rating values Specification...

Page 49: ...Technical data 49 Ambient conditions during operation Specification Value Unit Temperature range 25 70 C Relative humidity maximum non condensing 95...

Page 50: ......

Page 51: ...oor and up to 2 readers with operating current door strikes A D Connection diagram for 2 doors with up to 2 readers each with operating current door strikes A E Connection diagram for 3 doors with add...

Page 52: ...Connection diagrams 52 A Connection diagrams A A Connection diagram for 8 way relay module Fig 4 Connection diagram for 8 way relay module...

Page 53: ...Connection diagrams 53 A B Controller clamp assignments...

Page 54: ...Connection diagrams 54 A C Connection diagram for 1 door and up to 2 readers with op erating current door strikes...

Page 55: ...Connection diagrams 55 A D Connection diagram for 2 doors with up to 2 readers each with operating current door strikes...

Page 56: ...Connection diagrams 56 A E Connection diagram for 4 doors with up to 4 readers with operating current door strikes with additional WTX 200 I O board module...

Page 57: ...Connection diagrams 57 H fele GmbH Co KG Adolf H fele Str 1 D 72202 Nagold Germany Tel 49 0 74 52 95 0 Fax 49 0 74 52 95 2 00 E Mail info haefele de Cat No 732 29 127 Drawing number 6 161 005 90a...

Reviews: