2.  Flame Adjustment 
 
 
 
 
 
 
 

 

 

 

 
MAINTENANCE AND CARE 
 

1. Wipe Stainless Steel parts with a dry cloth and if it is difficult to Make them clean, 

you can use soapy water and dry cloth. 

2. Wash those Pan Support in water. 

3. Scrub those Burner Heads with wire Brush. 

 

SAFETY REGULATIONS 
 

1. Please do not touch some parts the cooker while the cooker is in operation or just 

finish from use, as they may reach very high temperature. 

2. Once the flame goes out unexpectedly, please turn off burner control, and have a 

try to re-ignite Burners after 1-2 minutes. If still Burners are not ignited, please stop 

the  operation  and  open  the  Cabinet  door  or  wait  for  some  more  minutes  before 

further attempt for ignition. (For both models.) 

3. Connections must be executed by a qualified person or technician according to the 

relevant standards for L.P.G.. For Town Gas, he must be a qualified license person 

or technician. 

4. If your gas type of the cooker needs changing, please ask a qualified or authorized 

personnel to complete the conversion. 

 

 

 

 

Summary of Contents for HH-782GG

Page 1: ...hob Hafele Thailand Limited 57 Soi Sukhumvit 64 Sukhumvit Rd Bangchak Phrakanong Bangkok 10260 Telephone 02 741 7171 HH 782GG 534 01 535 HH 752GS 534 01 504 HH 783GG 534 01 545 HH 753GS 534 01 512 HH 782GGA 534 01 575 HH 783GGA 534 01 585 ...

Page 2: ...g procedures push Ignition knob and turn it anti clockwise to Max position until you hear CLICK SOUND then both Outer and Simmer Burners will burn in Max Power Turn it further to Min position where Outer Burner will go out leaving only Simmer Burner burning Turn it back to Med position where Both Outer and Simmer Burners will burn in turned down power 2 IF FAIL TO IGNITE BURNERS Turn Ignition Knob...

Page 3: ...t overflow since it will spoil the burner Don t touch the parts of Burner or Pan Support or Casing since the surface of these parts will be very hot during operation NAME OF PARTS TOP PLATE BURNER HEAD PAN SUPPORT SIMMER BURNER IGNITION KNOB ...

Page 4: ... 450mm Product Two Burner Glass Hob Three Burner Glass Hob Model HH 782GGA 534 01 575 HH 783GGA 534 01 585 Ignition Battery Battery Overall Dimension 780 460mm 780 460mm Gas Consumption Type of Gas HH 782GG 534 01 535 HH 752GS 534 01 504 HH 783GG 534 01 545 HH 753GS 534 01 512 Max Power Max Power Max Power Max Power kW h kW h kW h kW h L P G 4 2 4 0 4 0 1 8 4 0 1 8 Gas Consumption Type of Gas HH 7...

Page 5: ...sure to keep paper oil and all other inflammable objects away from the gas hob At least 500mm should be kept between the gas hob and the gas cylinder Gas hob must always dispose of their combustion fumes through hoods connected to flues chimneys or straight outdoors If it is not possible to install a hood an electric fan can be installed on a window or on a wall facing outside This must be activat...

Page 6: ...SURE REGULATOR 2 8kPa Use approved gas hose and always secure the hose with a hose clamp The method of installation and gas supply must be in accordance with the requirements of the Local Authority of the area in which the hob is being installed Check the seal Once the appliances has been installed make sure all the connections are properly sealed especially sealing of the connection joints gasket...

Page 7: ... burner in an anticlockwise direction until it reaches the full on position ON then place a lighted match near the burner b Electrical ignition Depress and turn the knob corresponding to the required burner in an anticlockwise direction until it reaches the full on position ON You should hear a ticking sound from the electronic igniter The burner should light in a few seconds Matches can be used t...

Page 8: ...erature 2 Once the flame goes out unexpectedly please turn off burner control and have a try to re ignite Burners after 1 2 minutes If still Burners are not ignited please stop the operation and open the Cabinet door or wait for some more minutes before further attempt for ignition For both models 3 Connections must be executed by a qualified person or technician according to the relevant standard...