Summary of Contents for PM36500X

Page 1: ...ED SUPPLY DIMENSIONS 890 mm W x 520 mm D Models PM36500X Type A Models PM365S0X Type B FR INSTRUCTIONS POUR L INSTALLATION L ENTRETIEN ET page 9 L UTILISATION DES TABLES DE CUISSON ENCASTRABLES GAZ ET...

Page 2: ...eful without affecting the essential safety and operating characteristics This appliance has been designed for non professional domestic use only INFORMATION FOR THE INSTALLER The installation all reg...

Page 3: ...appliance and the back wall Attaching the hotplate To prevent liquids from leaking accidentally into the underlying storage space the appliance is equipped with a special gasket To apply this gasket c...

Page 4: ...cylindrical male in accordance with the norms UNI ISO 228 1 Fig 6 7 CONNECTION OF THE APPLIANCE TO THE ELECTRICITY SUPPLY Connection to the electricity supply must be carried out according to the norm...

Page 5: ...ductors and must also take heed of the warnings regarding electric connection Room ventilation Location and venting ATTENTION An exhaust fan may be used with the appliance in each case it shall be ins...

Page 6: ...s valves and electric components the hotplate must be removed from the bench top by releasing the attachment hooks loosening the attachment screws of each burner unscrewing the hotplate attachments nu...

Page 7: ...usage of pans Dry the bottom of the pan before placing it on the hotplate Use pots with a flat thick bottom except for wok cooking When using the burners ensure that the handles of the pans are correc...

Page 8: ...is maintained by periodically using suitable products which can be found in the supermarket Never use abrasive powders Cleaning the burner caps Lift the burner caps from the burner heads and wash them...

Page 9: ...imum des armoires suspendues est de 330mm 2 Distances lat rales Valeurs minimum Les diff rentes distances lat rales devront tre conformes aux valeurs minimum indiqu es dans la table n 1 et illustr es...

Page 10: ...v ase Fig 5B siempre que se respeten absolutamente las normas nacionales en vigor respecto a la ventilaci n de los locales CONEXI N DEL APARATO CON LA RED DE GAS Antes de conectar el aparato con la r...

Page 11: ...sez aussi les deux vis de fixation de la rampe du gaz au fond de la table qui se trouvent dans la partie sup rieure Sur les tables dot es de l allumage automatique d montez d abord la cat naire des in...

Page 12: ...essous 1 Allumez le br leur et mettez le bouton sur la position de MINIMUM petite flamme 2 Enlevez le bouton Fig 10 du robinet qui est r gl pour la pression standard Le bouton se trouve sur la barre d...

Page 13: ...me lorsque l alimentation est d branch e ou en cas de panne de courant prolong e Tournez le bouton qui correspond au br leur choisi dans le sens contraire des aiguilles d une montre dans la position...

Page 14: ...e par exemple en ouvrant une fen tre ou en augmentant la puissance du ventilateur tirage d air hotte d aspiration si install s Nettoyage de l appareil N utilisez jamais de produits nettoyer abrasifs A...

Page 15: ...15 Fig 1 Fig 2 Fig 3 Fig 3A Fig 3B Fig 4 Fig 5A Fig 5B...

Page 16: ...16 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14...