19
H
D
E
1
0
/2
019
732.
29.
20
0
2.2 Incorrect purpose
of use
Any use that is not mentioned in chapter 2.1 is considered to be improper.
The operator is solely responsible for any resulting damage. It is particularly
important to avoid the following:
• Use in potentially explosive environments
• Use in the vicinity of electromagnetically sensitive devices
• Use in aggressive environments (containing salt or chlorine, for example)
• Omitting components during installation
• Changes to the installation order
• Use of non-original parts
• Use of defective or damaged components
• Modifications or repairs to the product
3. Technical data
3.1 Connection and
power values
3.2 Interfaces
Voltage
- For UL conformity (UL 294)
12 V to 24 V DC, ±15%
12 V to 24 V DC, -15% / +10%
Current consumption, max.
(at 12 V)
0.2 A
Power consumption, max.
3 W
Safe-keeping
1 A
Lead type (all terminals)
0.13–0.52 mm
2
View
1x red LED, 1x green LED,
Piezo signal generator
Memory
Event log: Up to 1000 audit trail entries
key memory: Up to 1000 keys
digital input port
Switching input, max. 20 mA
Relay output port (changeover
contact)
- For UL conformity (UL 294)
48 V AC/DC, 5 A
40 V DC, 500 mA
Alarm output port (make)
- For UL conformity (UL 294)
48 V DC, 1 A
40 V DC, 1 A
RFID
Tag-It, Mifare Classic EV1, Mifare DESFire
EV1/EV2, LEGIC Advant
BLE (Bluetooth Low Energy)
Communication with mobile end devices
(contact the manufacturer for further
information)
ins-src-732.29.200.book Seite 19 Dienstag, 5. November 2019 12:13 12