GAS CONNECTION
Before to connect the appliance to the gas network, check that the adjustment sticker
data plate, put on the bottom of the appliance, correspond to the available one in the gas
network.
The adjustment sticker data plate, gives all the appliance’s setting conditions as: gas type
and gas operating pressures. Once installed, check there are no leaks using a soapy
solution only. Never use a flame! It is forbidden!
Prior to any maintenance work or before changing parts, disconnect the appliance from
the gas
The appliance’s gas inlet fitting is a G ½ male threaded cylindrical gas type in accordance with
the Standard ISO 228-1. When gas is distributed through ducts the appliance must be connect-
ed to the gas mains with:
#HNGZKDNGUVCKPNGUUUVGGNUGCONGUURKRGKPCEEQTFCPEGYKVJVJG0CVKQPCN4WNGUKPHQTEGYKVJ
a maximum 2 metres extension and seals in accordance with the National Rules in force. N.B.:
Make sure that the pipe, once the appliance is installed, does not come into contact with the
mobile parts of the unit in which the hob is built-in (like drawers for instance), get squashed or is
too bent.
#TKIKFUVGGNRKRGKPCEEQTFCPEGYKVJVJG0CVKQPCN4WNGUKPHQTEGYJQUGLQKPVUOWUVDGOCFG
WUKPIVJTGCFGFHKVVKPIUKPCEEQTFCPEGYKVJVJG5516JGWUGQHJGORYKVJUWKVCDNG
adhesives or Teflon tape as a sealant is not allowed.
#EQRRGTRKRGKPCEEQTFCPEGYKVJVJG0CVKQPCN4WNGUKPHQTEGYJQUGLQKPVUOWUVDGOCFG
using sealed fittings in accordance with the National Rules in force.
When gas is supplied directly from a gas cylinder, the appliance, supplied by a pressure regula-
VQTKPCEEQTFCPEGYKVJVJG5VCPFCTF'0OWUVDGEQPPGEVGF
9KVJHNGZKDNGUVCKPNGUUUVGGNUGCONGUURKRGUKPCEEQTFCPEGYKVJVJG0CVKQPCN4WNGUKPHQTEG
with a maximum 2 metres extension and seals in accordance with National Rules in force. N.B.:
Make sure that the pipe does not come into contact with the mobile parts of the unit in which
the hob is built-in (like drawers for instance), get squashed or is too bent. We recommend at-
taching the special adapter to the flexible pipe, easily found on the market, to facilitate connec-
tion to the pressure regulator’s hose fitting on the cylinder.
Anyway, the pipe connecting the appliance with the gas mains should lie with smooth bends
,and the rubber gasket preventing leakage added by user between the appliance’s gas inlet
fitting and the pipe connection must comply with the Standard EN 549 (get it in proper Technical
Assistance Centres or authorised dealers).
CAUTION:
*HYY`V\[[OLJVUULJ[PVUH]VPKPUNHSSRPUKZVMZ[YLZZ[V[OLHWWSPHUJL
MAINTENANCE
REPLACING COMPONENTS
- To replace other gas and electrical components, that are lodged inside the hob, it is enough to
remove the work top unscrewing the fixing screws of the burners
- Replace the seal each time you change a tap in order to guarantee a perfect tightness be-
tween body and rail.