Filter replacement
▲
Filter filter maintenance and replace
-Every three months, take off the filter, put it under the sunshine to make it dry and use
vacuum cleaner or soft brush to clean the dust on the filter. It will help extend the life of
the filter and keep the filter performance.
-Pre-Filterwith Activated Carbon, HEPA filter are no washable.
-Note: Filters should be replaced at least once each 6 months. More frequent cleaning and
replacing may be required depending on environmental conditions.
UV Lamp replacement
1. Open the UV lamp cover by a screw driver.
2. The UV Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and
twisting the bulb 1/4 turn. Remove from unit.
3. Install the new UV lamp and re-attach the cover.
Note:
Do not watch the operating UV lamp directly.
Maintenance caution
▲
Product cleaning
-Make sure unplug before cleaning the appliance.
-Do not put the appliance into the water or use the water to wash directly.
-Do not use any corrosive or flammable detergent to clean the appliance, in case any
damage.
-Can use the soft cloth with daily cleanser to clean the appliance, and make sure the
appliance is dry after cleaning.
-Regularly clean the inside and surface, to prevent dust gather.
-Regularly clean the air inlet and air outlet.
-Regularly clean the dust sensor by a cotton swab to protect its sensitiveness.
▲When long time no use
Red Reset button on the housing