17
ENG
NOTE
Water and electricity must be connected by qualified professionals (HVAC specialist/electrician) as set out below.
Water
Connected as per the connection diagram for the main pipe system.
1/2 inch approved hose with shut-off valve (Ballofix or similar).
Water pressure ≤ 10 bar, temp min. 55
o
C, max. 60
o
C.
All visible connections must be inspected and tightened.
Electricity
Connected using the wiring diagram and technical data in accordance with heavy current regulations in force.
RCD: At least IP56 and rated trigger < 30 mA.
Omnipolar circuit breaker: 3 mm contact separation.
Earth potential 6 mm
2
.
Any live parts incorporated, with the exception of electrical components supplied with extra low voltage not exceeding 12 V, may
not be open to access by anybody in the steamer. All visible connections must be inspected and tightened.
Checklist
In the event of an electrical fault, always turn off the main power supply for 5 minutes.
If the product is to be serviced, it must be easily accessible and located at least 1 m from a wall.
Contact Hafa if you cannot remedy the fault or if error codes E1, E2, E3, E4, E5 or E6 appear.
Fault
Action
No power
1. Is the electricity connected?
2. Has the RCD tripped?
3. Is the main switch on?
4. Is the fuse in the house or steamer faulty (see wiring diagram/Reset button)?
No steam
1. Is the water connected?
2. Has it been on for 3 mins without any steam?
3. Is the hose to the box and steam intake intact?
No water
1. Is the water connected?
2. Are the hoses trapped?
No light
1. Is the steamer turned on?
2. Is the wire to the lamp damaged or is there a bad contact?
Display does not work/works poorly.
1. Is the steamer turned on?
2.
Has the button been held down for more than 5 secs in order to unlock the child safety lock?
3. Is the wire to the display damaged or is there a bad contact?
Poor drainage from the plughole
(21 litre/min)
1. Have the floor drain and plughole been cleaned?
2. Is the hose in the correct position and not trapped?
Steamer unit does not empty
1. Must empty gradually within 10 mins.
Installation
Summary of Contents for Kioto Steamer 90 Square
Page 1: ...Kioto Steamer 90 Square 201 1 06 08 ...
Page 6: ...6 1 2 m n o p q 2 l ENG Electrical installation must be performed by a qualified electrician ...
Page 7: ...7 ...
Page 8: ...8 ...
Page 9: ...9 ...
Page 10: ...10 ...
Page 11: ...1 1 Drain pipe S team G enerator Drain pipe S team G enerator N L ...
Page 19: ...19 ...