background image

 

 

 

 

16 

 

 

5.52.288.00.01.06

 

Commissioning 

 

9.1 

General 

Should the unit be used in Germany:  
Please observe the validated, national accident prevention regulations. 
For other countries:  
Inspections as above. Please observe the national rules and regulations and the instructions in this manual! 

 

 

 

NOTICE!

 

Hoists up to 1000 kg capacity and without motor-driven trolleys of hoisting unit must be tested by a “qualified 
person” before putting into operation for the first time. 
Hoists of 1000 kg capacity and up or with more than one motor-driven hoist movement; i.e. lifting and trolley 
movement, must be tested by a “licensed qualified person” before putting in operation. 
An  exception  is  “hoists  ready  for  operation”  acc.  validated  national  regulations  with  EU-declaration  of 
conformity. 

Definition “qualified person” (former expert) 

A “qualified person” has learned, due to occupational training and experience and the job that the person has 
done, the skills needed to tests the material for one’s work. 

Definition “licensed qualified person” (former approved expert) 

A “licensed qualified person” has, due through special occupational training, knowledge about testing of the 
material for one’s work and knows the national accident prevention regulations and other prescriptions and 
technical regulations. This person must test the material for one’s work regularly with regard to design and 
kind of use. The license will be given to qualified person be the approved supervision authorities (ZÜS). 

 

9.2 

Power supply 

9.2.1 

Mains connection 

Hoist motor technical data can be found it in the "Technical data" chapter. 
The following tables show the assignment of the fuses. 

  Select connection cross-sections as per VDE 0100. 
  Put sleeves on the ends of the cables. 
  Insert the connection cable into the connection plug without strain. 
  Secure lines as per VDE 0100. 

9.2.2 

Control line connection 

Pendant with cable and plug-in connection. Plug-in before use. 
Any changes of the power supply cable must only be effected by qualified personnel. 

9.2.3 

Power connection of the brake 

The  low-maintenance  D.C.  spring-pressure  brakes  are  connected  at  the  factory  according  to  the  wiring 
diagram. 

 

 

 

 

NOTICE!

 

The  power  supply  cable  must  be  equipped  by  the  customer  with  slow-blow  fuses  and  mains  connection 
switch. 
 

 

   

CAUTION!

 

Precondition for actuation of the overload protection is the correct winding direction of the wire rope! 
This may be mixed up for winches with three phase current motor. 
The symbols on the control switch than do not match to the wiring direction of the wire rope.  
In this case, the winch must be stopped immediately. 
Exchange two phases of the main current supply.  
Test the winding direction of the wire rope. 
 

 

Summary of Contents for 43/86E-Liftboy

Page 1: ...5 52 288 00 01 06 Rev 06 HADEF Electric Wire Rope Winch Type 43 86E Liftboy Installation Operating and Maintenance Instructions ...

Page 2: ...to determine the used part of the theoretical usage life 4 2 Safety 4 2 1 Warning notice and symbols 4 2 2 Duty of care of the owner 4 2 3 Requirements for the operating personnel 5 2 4 Appropriate use 5 2 5 Basic safety measures 6 3 Transport and Storage 7 3 1 Transport 7 3 2 Safety device for transport 7 3 3 Storage 7 4 Description 8 4 1 Areas of application 8 4 2 Design 8 4 3 Functions 9 4 4 Im...

Page 3: ...osal 25 18 Additional documents 25 18 1 Electric wiring diagrams 25 18 2 Radio control as option 25 1 Information The products meet European Union requirements in particular the valided EU Machine Directive The entire company works acc to a certified quality assurance system as per ISO 9001 The production of components at our work is subject to strict intermediate checks After assembly each produc...

Page 4: ...This means that there is a high risk that leads if it is not avoided to death or severe injury WARNING This means that there is a risk that could lead if it is not avoided to death or severe injury CAUTION This means that there is little risk that could lead if it is not avoided to slight injury or damage to the device or its surrounding NOTICE Gives advice for use and other useful information Dan...

Page 5: ...ot removed and remain legible Devices for use in area prone to explosion must from customer s side be earthed with a shunting resistor of 10 6 Ω against earth WARNING It is not allowed to make constructive changes of the equipment 2 3 Requirements for the operating personnel The units may only be operated by qualified persons that are appropriately trained and that are familiar with it They must h...

Page 6: ...n with this equipment must provide an adequate safety factor to handle the rated load plus the weight of the equipment In case of doubt consult a structural engineer If the equipment has not been used for a period of time carry out visual checks of all main components such as chains load hooks etc and replace any damaged parts with new original spare parts before putting the equipment back into op...

Page 7: ...on of remaining safe working period must be observed WARNING The following is not allowed to lift another load than the nominal safe working load to manipulate the sliding clutch if units are equipped with The use of elongated or damaged chains or wire ropes Replace them immediately by new original parts Never loop the load chain around a load nor place or pull the chain over edges Never repair da...

Page 8: ...ween the two housing halves offers wire rope exits in several directions Different installation positions are possible make sure the drum axle is always positioned horizontally Available for single phase current or 3 phase current Single phase current 3 phase current 4 2 1 Wire rope exit For winches with ungrooved drum the rope can be winded round the drum in both directions In case of changes of ...

Page 9: ...ns that apply The overload protection prevents lifting a load that is too heavy by switching off the hoisting motor When putting the winch into operation or after current of the winch has been cut off or after the overload protection has operated press the button lowering shortly to re activate the relay A re adjustment i e for maintenance reasons is possible Control Low voltage control direct con...

Page 10: ...4 5 1Bm 0 37 1 1 78 26 125 6 5 16 90 32 30 22 4 4 5 0 75 1 9 79 26 125 6 5 11 2 8 90 32 30 15 3 8 4 4 5 0 35 0 07 1 3 0 7 79 26 250 7 5 5 180 35 34 7 4 4 9 0 37 1 1 78 37 250 7 5 10 180 35 34 14 4 4 9 0 75 1 9 79 37 250 7 5 7 1 8 180 35 34 9 2 2 4 4 9 0 35 0 07 1 3 0 7 79 37 500 5 4 2 5 340 30 29 4 4 6 18 0 37 1 1 78 38 500 5 4 5 340 30 29 8 4 6 18 0 75 1 9 79 38 500 5 4 4 1 340 30 29 5 5 1 4 4 6 ...

Page 11: ... valid for grooved drum measured at a distance of 1 m from the surface of the unit and 1 6 m over the assembly area tolerance 2dB A 3 phase current motor 400V 50Hz or alternating current motor 230V 50Hz IP55 F max 1000 m above sea level Order related Special data refer to the motor nameplate 6 Installation Please observe the following points in order to avoid any damage to equipment or injury of p...

Page 12: ...l box must be changed accordingly The kind of wire rope fastening and the winding direction are determined for winches with grooved drum by the direction of the grooves on the drum Before cutting the wire rope wrap it firmly with a fine binding wire or strong adhesive tape 6 3 1 125 kg Fasten the wire rope with countersunk screw and clamping disc in the hub situated at the inner side of the big fl...

Page 13: ...lection angle must not be exceeded maximum wire rope deflection angle 4 for standard wire ropes 2 for non twisting resp twist resistant wire ropes The minimum dimension M from the drum until the middle of the pulley must be adhered to Illustration 6 NOTICE Should the drum be extended and for some models with limit switch the distance M must be increased Standard values 15x 1 2 drum length for stan...

Page 14: ...l Control buttons Control symbols shown are for optical information only and can vary depending on the control module Emergency stop Illustration 7 Arrow keys Lifting Lowering Illustration 8 System start optional Illustration 9 Push button functions E Relieved push button stand still push button half pushed slow speed push button pushed completely fast speed Illustration 10 Red Emergency Stop butt...

Page 15: ...he following important points must be observed when operating the equipment Read the safety instructions Never load the devices beyond their working load limit When changing the motor turning direction allow the motor to come to a standstill first The prescribed maintenance intervals must be adhered to Observe the duty cycle i e intermittent operation S4 40 ED as per VDE 0530 means that in a perio...

Page 16: ...r prescriptions and technical regulations This person must test the material for one s work regularly with regard to design and kind of use The license will be given to qualified person be the approved supervision authorities ZÜS 9 2 Power supply 9 2 1 Mains connection Hoist motor technical data can be found it in the Technical data chapter The following tables show the assignment of the fuses Sel...

Page 17: ...5 2 5 4 2 2 16 4 20 2 5 4 6 5 5 35 4 10 12 50 6 10 NOTICE The values listed in the table refer to 400V 50 Hz three phase current and are recommendations The exact determination of the supply line must be carried out on site by a specialist Alternating current design Motor output kW Fuse Slow blow A Start up Nominal current Ia In Line cross section mm for line length L m L 50 50 L 100 100 L 150 0 5...

Page 18: ...witch prevents further unwinding of the wire rope 9 6 1 Function The weight of roller lever and guide pulley actuates rotation of the switching shaft with eccentric disc in case of slack wire rope The eccentric disc pushes the switching pin of the limit switch down until the switching contacts in the circuit for lowering open Lowering without load is impossible Should this however be necessary i e...

Page 19: ...s must be shortened correspondingly 12 3 Brake motor Brake 180 V DC Winch Capacity kg Motor Nominal brake moment Nm Nominal air gap mm air gap max mm min mm 125 500 3 phase current 5 0 2 0 4 1 5 friction lining thickness 1000 3 phase current 15 0 3 0 45 1 5 friction lining thickness 2000 3 phase current 26 0 3 0 45 1 5 friction lining thickness 3200 3 phase current 32 0 3 0 7 8 0 rotor strength 12...

Page 20: ... power limiter as option except serial AT Power consumption of the hoist motor is measured during lifting movement of a load by an adjustable power measuring device overload guard The setting is made via a separate relay for main and creep lifting speed Power consumption of the motor is load dependent and increases with the load If the set value is exceeded the relay responds immediately and switc...

Page 21: ...ith the locking screw Switch on the winch in direction Lowering and relieve the wire rope Repeat this procedure if necessary until the best switching point is found Illustration 18 13 Inspection 13 1 General Overhaul for motor driven units The validated national accident prevention regulations must be observed and the measures to reach safe working periods S W P according to FEM 9 755 After the th...

Page 22: ...qualified person periodic inspection X Check screw connections X X Check brake function X X check brake air gap only for electric devices X check overload protection if existent X clean and lubricate the wire rope X X X check wire rope and wire rope end fastenings for damage and wear X check the load tackle and load hook for cracks and deformation X not for EX design Lubricate the toothed wheel of...

Page 23: ...TIS EP2 Renolin B10 VG32 Tellus Oil 32 Stabylan 5006 Optimol Viscoleb 1500 Klüberoil 4UH 1 1500 Chain lubricant OKS 451 14 5 Lubricant for food industry selection as option FUCHS SHELL MOBIL CASTROL KLÜBER Gear Geralyn SF 220 Cassida Fluid GL 220 Glygoyle 220 Optimol GT 220 Klübersynth UH1 6 220 Driving gear Geralyn SF 320 Cassida Fluid GL 220 Glygoyle 320 Optimol GT 320 Klübersynth UH1 6 320 Load...

Page 24: ...s not release See problem Brake does not release Defect of capacitor only for alternating current 1 Replace the capacitor Defect of starter relay only for alternating current 1 Replace the starter relay Phase failure only direct control Find the cause and repair Motor does not brake or has excessive afterrunning Electric hoists and winches Switching error after intervention in the electric circuit...

Page 25: ... all operating material is disposed of in accordance with environmental regulations 17 1 Temporary decommissioning Measures are as above Also read the chapter Transport and storage 17 2 Final decommissioning disposal Measures are as above After disassembly ensure that the disposal of the equipment and any materials it contains is carried out in accordance with environmental regulations 18 Addition...

Reviews: