5.52.693.01.01.00 

 

 

 

  Use protective clothes/equipment. 

  Do not wear long hair hanging down open. 

  Do not wear rings or other jewelry. 

  Do not wear clothes that are too big/wide. 

  Do not reach into ropes, chains, drive parts or other moving parts with your hands 

 

2.4 

Appropriate use 

The permitted safe working load of the devices must not be exceeded! An exception can be made during the 
load test before initial operation, carried out by a licensed qualified person. 

 

 

  Defective  devices  and  load  suspension  devices  must  not  be  used  until  they  have  been  repaired!  Only 

original spare parts must be used. Non-compliance will result in any warranty claims becoming void. 

  Liability and warranty will become void if unauthorized modifications of the units are made by the user! 

  The permissible ambient temperature when operating the devices: 

Type of drive 

Device classification for 

Not explosive atmosphere 

Explosive atmosphere 

according to  

 ATEX 

)* )**

 

Manually driven 

-20°C/+50°C 

-20°C/+40°C 

Motor driven 

-20°C/+40°C 

-20°C/+40°C 

 

) * At an atmospheric pressure range from 0.8bar to 1.1bar and an oxygen content of approx. 21% 

) ** Devices of this category have been specially modified and labeled by the manufacturer

 

   

DANGER!

 

The permissible ambient temperature must not be exceeded! 

 

Moving horizontally on beams. 

 

 

   

DANGER!

 

The use is not allowed: 

  for pulling loose of stuck loads, dragging of loads and inclined pulling. 

  in explosive atmosphere, except the unit is especially modified for it and marked by an indication label. 

  in reactor containment vessels. 

  to transport people. 

  The device is not suitable for use on stages and in studios. 

Persons must not stand under a suspended load. 

 

 

 

 

NOTICE!

 

If the units are not used appropriately, it is not possible to ensure safe operation. 

The  owner  and  operator  have  sole  liability  for  all  personal  injury  and  damage  to  property  arising  from 
inappropriate use. 

 

 

   

DANGER!

 

It’s only allowed to use the unit in the EX-classification which is named on the type plate; or in lower 
classes 

 

2.5 

Basic safety measures 

  Observe installation-, operation and maintenance instruction. 

  Take notice of caution notes at units and in the manual 

  Observe safety distances. 

  Take care for a free view on the load. 

  Only use the hoists appropriately. 

  The equipment is to be used exclusively for movement of goods. Under no circumstances my persons be 

moved. 

  Never load the devices beyond their working load limit. 

Summary of Contents for 32/20EX

Page 1: ...2D Ex h IIIA T135 C Db II 2G Ex h IIB T3 Gb or II 2D Ex h IIIA T200 C Db DANGER Not to be used with IIC gases and IIB gases hydrogen sulphide and ethylene oxide and light metal and shock sensitive du...

Page 2: ...Information 3 2 Safety 3 2 1 Warning notice and symbols 3 2 2 Duty of care of the owner 4 2 3 Requirements for the operating personnel 4 2 4 Appropriate use 5 2 5 Basic safety measures 5 2 6 Explosio...

Page 3: ...damage immediately to the forwarding agent This manual serves for safe and efficient use of this hoist Illustrations serve to explain something and may differ from the illustration of the existing un...

Page 4: ...uipment i e regarding organization of work work flow and human resources In particular the owner user must ensure that The unit is only used appropriately The device is only operated in a fault free f...

Page 5: ...21 Devices of this category have been specially modified and labeled by the manufacturer DANGER The permissible ambient temperature must not be exceeded Moving horizontally on beams DANGER The use is...

Page 6: ...ide and light metal and shock sensitive dusts No use in temperature class T5 or T6 It is not allowed to use the equipment in area at risk from explosion where gas AND dust does both exist at the same...

Page 7: ...ding e g c construction safety k encapsulation of liquids IIB explosion group II gases IIA IIB IIC limit gap widths MESG 0 9 mm limit gap widths MESG 0 9 to 0 5 mm limit gap widths MESG 0 5 mm T4 Temp...

Page 8: ...ixtures for T5 do not occur with normal use and only very rarely occur for T6 for specific gas air mixtures such as carbon disulphide IIC our hoists are not rated for these temperature classes and mus...

Page 9: ...5 52 693 01 01 00 9 2 6 4 Explosion hazards recognizing and preventing 3 Transport and Storage...

Page 10: ...GER Units that show corrosion must be taken out of service 4 Description 4 1 Areas of application The devices must be as far as possible installed in a covered room If they are used in the open protec...

Page 11: ...all standard beams with inclined and parallel flanges Side plates Made of steel plate with integrated wheel fracture supports load bars Device with 2 load bolts Different bolt lengths are available f...

Page 12: ...e inner side X increases or from the inner to the outer side X decreases Washers 6 and rubber discs depended on type leave a distance for the load hook It is important that the load hangs in the middl...

Page 13: ...mm 1 1 5 mm each side bigger and for trolleys from 4 t up 3 5 mm 1 5 2 5 mm each side bigger than the flange width B of the beam 6 4 Tools 7 Control Only people that are familiar with the operation o...

Page 14: ...regard to design and kind of use The license will be given to qualified person be the approved supervision authorities Z S 9 Safety check Before putting into service initially or when putting back in...

Page 15: ...BER Renolit FEP 2 Alvania EP 2 Unirex EP 2 Mobilux EP 2 MULTIS EP2 Stabylan 5006 Optimol Viscoleb 1500 Kl beroil 4UH 1 1500 Wolfracoat 99113 Chain lubricant OKS 451 13 2 Lubricant for food industry S...

Page 16: ...datory that all steps for decommissioning the machine are carried out in the indicated sequence First secure the working area for decommissioning leaving plenty of space Read the chapter Safety instru...