background image

 
 
7. Rotation reverse 
 

Reverse motor rotation   

W  W  W  W  W 

 

8. Active RPM-Control, Heli-/ Governormode

 

 

rpm control

: Off  

                        _._   _._   _._   _._   _._ 

up to 20 000 electrical RPM:

      _.._   _.._   _.._   _.._   _.._ 

up to 50 000 electrical RPM:

      _…_   _…_   _…_   _…_   _…_ 

above 50 000 electrical RPM:

    _…._   _…._   _…._   _…._   _…._ 

 

(electrical RPM on two-pol motors, for a 4-pol motor for example:  
50 000 electrical RPM:2 = 25 000RPM, 10-pol motors electrical 50 000RPM:5 
 = 10 000RPM and so on…)

 

 
 
Trouble shooting: 

 

  Switch “ON” the transmitter and check the throttle channel settings are +/-100% (for 

computer radios). For Futaba Radios program the “Servo Reverse” function on the throttle 
channel. 

Set the throttle to “closed” or brake position

 

  Locate the controller to Avoid multiple touches of the connectors when installing a fresh 

motor battery pack 

  You must hear a ‘beep’.  

Between switching on the switch and the ‘beep’ the throttle 

stick must not be moved

. If you do not hear a ‘beep’, switch off the switch, disconnect 

the power connectors, wait for 5 seconds and repeat the procedure of connecting and 
switching on.  

  If you do not hear ‘beep’ again, check the following: 

o

 

    Is JR connector plugged in throttle chanel? 

o

 

    Is the throttle stick in “closed” position (OFF)? 

o

 

    Is the throttle channel in ‘normal’ position? (for Futaba, in the  Reverse 

position?) 

  The position of  ‘full throttle’ will be adjusted automatically 

  All programming will be stored. 

 
 
 

 

The speed controller will turn-off the motor when the main power pack voltage falls    

     under 5,5 V or at the voltage wich is programed in step “under voltage”. It depends on which 
occurs first.  

 

Temperature overload protection is built into the speed controller; it turns off the motor when the 
temperature reaches 230º F /110º C.  

 

These speed controllers are equipped with protection functions that take care of correct start 
and operation of the motor across the whole range of RPM, Current and Voltage. 

 

Do Not connect the speed controller to just ‘any’ kind of power source.

 Take care to 

ensure the right polarity of NiCd/ NiMH or LiPoly power packs only. 

 

 

Do not connect the motor battery to the wrong polarity; the speed controller will be 

severely damaged.  

 

Controllers connected to the wrong battery polarity, WILL NOT be covered under the 
warranty 

 
 

Copyright 06/07 – Hacker Motor GmbH   4 

Summary of Contents for Pro Series

Page 1: ...s possible to extend the cables to the motor battery pack up to a maximum of 8 inches Deans Ultra or other high quality connectors are recommended for connecting the motor battery pack to the controller Solder Controller to the Motor wires Solder appropriate connectors to the Battery wires Insulate all Solder connections with Heat Shrink Tubing Plug the JR connector into the receiver throttle chan...

Page 2: ... adjusting parameters variable cutoff voltage for LiPo cells Brake off soft hard finer gradations in the Motortiming acceleration in three stages selectable updates for the X Pro ESC programming by throttlestick With throttle stick at full power connect the battery and wait for 5 sec Program mode is entered when you hear two low tones and two high tones _ _ Each time you enter the programming mode...

Page 3: ...14 5V 6 Lipos 17 4V Following cell setting only available in OPTO Versions 7 Lipos 20 3V 8 Lipos 23 2V 9 Lipos 26 1V 10 Lipos 29 0V 3 Under voltage reduces power when the battery gets low _ _ _ _ _ cuts off power when the battery getslow _ _ _ _ _ 4 Acceleration Low V V V V V Medium VV VV VV VV VV High VVV VVV VVV VVV VVV 5 Timing Automatic 7 30 degree recommended Soft 7 degree 2 pole motors Hard ...

Page 4: ...cting and switching on If you do not hear beep again check the following o Is JR connector plugged in throttle chanel o Is the throttle stick in closed position OFF o Is the throttle channel in normal position for Futaba in the Reverse position The position of full throttle will be adjusted automatically All programming will be stored The speed controller will turn off the motor when the main powe...

Page 5: ...uthorize all returns within 7 days from receipt of order All returns must have a copy of the original invoice with MRA number All returning packages must have the MRA number clearly marked on the outside of the packaging All packages shall be inspected upon delivery All claims for damaged products must be made with carrier within 3 days of the receipt of the package All defective items must be pro...

Page 6: ...icable EC guidelines for electromagnetic compatibility 89 336 EWG 92 31 EWG 93 68 EWG Many happy landings Hacker Motor GmbH Hummler Str 5 Tel 0049 0 8761 752 129 Fax 0049 0 8761 754 314 EMAIL info hacker motor com D 85416 Niederhummel WEEE Reg Nr DE 55352581 Copyright 06 07 Hacker Motor GmbH 6 ...

Reviews: