Page 31 of 38
Brushless DC Controller HST-70
Orginal
operating
manual
Rev1.2
Mounting and commissioning
4.4 Operating the controller with the GUI and settings in the software
The following is required for commissioning the controller:
• A Windows computer with the GUI installed. You will receive the installation package from us
upon request.
• A USB to CAN adapter (order #10107621) (optional driver download at
www.hacker-industrial-solutions.com/downloads/
)
• The controller must be connected and powered as shown above.
• The motor should be able to rotate freely for the test
Connect the CAN bus lines of the 12-pin Molex connector
• Yellow / CAN High [Pin 10]
• Green / CAN Low [Pin 9]
with the CAN adapter. Solder on the corresponding contacts (in the example: Ø2 mm gold con-
tacts).
CAN High
CAN Low