Identification and Authorization Level 

Press the closed padlock icon (top right of the
screen) to open the identification window. The
user identification and password must be entered
to access functionalities authorized by the
security level of the given user. 

Views

The numeric view is the default view and shows
numeric measurement value identified for the gas
measurement channel, a graphic showing
measurement value evolution during the set time
frame, and sample temperature. 

T h e   d i a g n o s t i c   w i n d o w   c o n t a i n s   u s e f u l
information for troubleshooting purposes. The
amount of information displayed depends on the
g a s   b e i n g   m e a s u r e d   a n d   t h e   c h a n n e l
configuration.

The statistical view offers statistical data that
matches with Total Quality management tools.
Statistics is a tool to better analyze how a process
behaves.

Abnormal Conditions

Whenever an abnormal event is encountered, a
sign is displayed on the upper left of the screen
(see example below). 
Pressing on the sign calls a window giving further
details about the actual situation. 

There are three levels of abnormal conditions:

Alarm

 - There is a severe problem causing

the channel to be out of action, and the
system alarm relay to be enabled

Warning

 - Events less critical than a

system alarm (e.g. measurement alarm)

Information - 

For information only, no

action is required

Operating Information (cont)

Summary of Contents for ORBISPHERE 410

Page 1: ...Operator Quick Guide ORBISPHERE 410 Revision E 24 04 2008...

Page 2: ...interface software is Windows CE based providing easy selection through menus All the measurement configuration calibration and standard service routines can be called by pressing buttons and menu bar...

Page 3: ...f information displayed depends on the gas being measured and the channel configuration The statistical view offers statistical data that matches with Total Quality management tools Statistics is a to...

Page 4: ...lved Gas unit The list of available units depends on unit type selected above Liquid When medium is liquid select water or a liquid with a different solubility if available Display resolution Maximum...

Page 5: ...ntration values are above High alarms or below Low alarms Set this to a minimum but enough to avoid alarms for non representative peaks beyond the set level Measurement Filter Configuration The filter...

Page 6: ...the buffer is full Adjust the parameters for recording and storing measured data Storage mode selection No storage Store once When volatile memory is full 1 000 positions measurement recording stops R...

Page 7: ...the Modify button Last calibration parameters are memorized so this step can be ignored if correct parameters are already set Modify Calibration Parameter Calibration mode 2 types available depending...

Page 8: ...saturated air to provide a known oxygen reference against which to calibrate Dry the sensor thoroughly before placing the sensor storage cap under tap water Shake off any excess water but leave a few...

Page 9: ...tion temperature barometric pressure current the date and time the user name and ID Barometric Pressure Calibration Upper box shows the barometric pressure measured by the instrument Using a precision...

Page 10: ...cing and maintenance For more information on this please refer to the corresponding sensor maintenance manual Language Check the language as required and restart the instrument to apply the change The...

Page 11: ...urement is frozen Alarm low low The gas concentration is below the Alarm LowLow limit Alarm low The gas concentration is below the Alarm Low limit Alarm high The gas concentration is above the Alarm H...

Page 12: ......

Reviews: