1.
Carefully put the flow chamber on the sensor head in the sensor holder (E). Make sure not to
touch the membrane or damage to the membrane can occur. Tightly screw the sensor collar to
attach the flow chamber into its location.
2.
Put the LEMO plug that is on the end of the sensor cable into the sensor socket of the indicating
instrument.
3.
Connect approximately 25 cm of plastic tube from the top of the piercing head (A) to the inlet
Swagelok fitting on the flow chamber.
4.
Connect the gas supply as follows:
a.
Connect the gas supply to the 6 mm brass Swagelok gas supply connector assembly (D) on
the sensor holder (E) with a nylon tube.
b.
Connect the brass Swagelok gas supply to the lower piercing column Swagelok assembly (C)
with a nylon tube.
c.
Use the knurled screw (B) on the same black block as the gas inlet port as a gas on/off valve.
Note: Use nitrogen or carbon dioxide as the forcing gas supply based on the beverage package application.
5.
Make sure that all Swagelok fittings are tight.
Figure 4 EC/TC sensor sampler assembly
Assemble the LDO sensor
N O T I C E
If tubing replacement is necessary, make sure to use material of low gas permeability, such as flexible nylon,
PVC, or tygon for tube replacement. Do not use metal tubing or damage to the brass connectors can occur.
and do the steps that follow to assemble the system:
1.
Install the U-shaped ring to hold the flow chamber on the correct position (D).
2.
Put the flow chamber in the correct position (D). Make sure that the tubing points to the front.
Tighten the screws of the U-shaped ring to attach the flow chamber into its location.
3.
Install the LDO sensor in the flow chamber. Tighten the screw in the collar on the LDO sensor to
the flow chamber.
English
9
Summary of Contents for 29971-72
Page 6: ...Figure 2 Piercing heads Photo Q 29974 Photo R 29973 6 English...
Page 26: ...Abbildung 2 Anstichvorrichtungsk pfe Foto Q Modell 29974 Foto R Modell 29973 26 Deutsch...
Page 47: ...Figura 2 Testine di foratura Foto Q 29974 foto R 29973 Italiano 47...
Page 67: ...Figura 2 Cabezales de perforaci n 29974 en fotograf a Q 29973 en fotograf a R Espa ol 67...
Page 87: ...Obr 2 Propichovac hlavice fotografie Q 29974 fotografie R 29973 e tina 87...
Page 106: ...Afbeelding 2 Naaldhouders Foto Q 29974 foto R 29973 106 Nederlands...
Page 126: ...Rysunek 2 G owice nak uwaj ce Zdj cie Q 29974 zdj cie R 29973 126 Polski...
Page 147: ...Figura 2 Capete de perforare Imaginea Q 29974 Imaginea R 29973 Rom n 147...
Page 165: ...1 1 165...
Page 166: ...1 29971 166 29972 168 1 1 4 2 5 3 6 29971 29971 2 182 29971 29973 R 2 R3 2 R6 2 R4 2 166...
Page 167: ...2 Q 29974 R 29973 167...
Page 169: ...8 3 3 1 6 11 2 7 12 3 8 13 4 9 5 10 EC TC Tygon 4 169...
Page 170: ...1 E 2 LEMO 3 25 Swagelok 4 a 6 Swagelok D b Swagelok c B 5 Swagelok 4 EC TC LDO Tygon 5 170...
Page 171: ...1 U D 2 D U 3 LDO LDO 4 LEMO 5 A 16 15 POM 6 7 Swagelok C B 8 Swagelok 5 LDO 171...
Page 173: ...6 29089 1 6 6 2 7 3 8 4 6 9 5 31560 31590 N2 CO2 N2 164 31460 31490 CO2 CO2 99 8 CO2 164 173...
Page 175: ...4 a EC EC b LDO c TC CO2 N2 TC 172 5 0 5 1 CO2 TC 6 3 7 1 2 B 3 C 4 5 D 6 E 7 175...
Page 176: ...7 Startup 174 1 176...
Page 177: ...6 20 50 2 3 8 4 F 200 100 5 CO2 6 7 a b c d 177...
Page 178: ...8 1 2 3 Hach 29089 172 32301 32301 EC ORBISPHERE 32301 178...
Page 180: ...40 C 104 F 1 5 1 2 CO2 N2 TC CO2 N2 TC EC TC LDO LDO 180...
Page 188: ...2 bra Sz r fejek 29974 Q f nyk p 29973 R f nyk p 188 Magyar...
Page 205: ......