11
Press the “
” button one time when heat pump is on, the
or
will be flash.
Press the “
” or “
” button to choose the mode, and press “
” button to
confirm.
Defrosting
Automatic defrosting: When enter to automatic defrost function, the icon
on the top of
screen will flash; When finish defrosting, the machine switch automatically to the mode
before defrosting.
Compulsory defrosting: when the heat pump is heating and the compressor is working
continuously for 10 minutes, press both “
” and “
” buttons for 5 seconds to start
compulsory defrosting. (Note: the interval between compulsory defrosting should be more
than 30 minutes.)
The heating light
will be twinkling when heat pump is in compulsory or auto
defrosting
.