8
B. Installation instruction
1) Location and size
The heat pump should be installed in a place with good ventilation
2) The frame must be fixed by bolts (M10) to concrete foundation or brackets. The concrete
foundation must be solid and fastened; the bracket must be strong enough antirust treated;
3) Please don’t stack substances that will block air flow near inlet or outlet area, and there is
no barrier within 50cm behind the main machine, or the efficiency of the heater will be
reduced or even stopped;
4) The machine needs an appended pump (Supplied by the user). The recommended pump
specification-flux: refer to Technical Parameter, Max. lift ≥10m;
5) When the machine is running, there will be condensation water discharged from the
bottom, please pay attention to it. Please hold the drainage nozzle (accessory) into the hole
and clip it well, and then connect a pipe to drain the condensation water out.
* MINIMUM DISTANCE
Filter
Water processor
Water switch
Summary of Contents for 1436 103290
Page 1: ...Eco 1436_103290_103291_103292...
Page 19: ...17 XI Annexe 1 Sch ma de c blage pour le contr le externe Optionel...
Page 20: ...18 XII Annexe 2 Sch ma de c blage pour le contr le externe Optionel...
Page 22: ...Ecoline Inverter INSTALLATION AND USER MANUAL INVERTER SWIMMING POOL HEAT PUMP FR EN DE IT ESP...
Page 40: ...17 XI Appendix 1 Heating priority Optional...
Page 41: ...18 XII Appendix 2 Heating priority Optional...
Page 61: ...18 XI Anhang Schaltplan f r Zwangseinschaltung der Filterpumpe Optional...
Page 62: ...19 XII Anhang Schaltplan f r Zwangseinschaltung der Filterpumpe Optional...
Page 104: ...17 XI Ap ndice 1 Diagrama de cableado de prioridad del calentamiento opcional...
Page 105: ...18 XII Ap ndice 2 Diagrama de cableado de prioridad del calentamiento opcional...
Page 107: ......
Page 108: ...Version Cf 7IN...