SION  OF  OWNER  AND  READING  AND  UNDERSTANDING  PRODUCT 
SAFETY, INSTALLATION AND INSTRUCTION MANUAL.
DISCONNECT POWER BEFORE ACCESSING MECHANICALLY FASTENED 
AREAS.

1.  Check that the power supply conforms to the data plate located on 

the upper right interior wall of the cabinet.

E. START-UP

  NOTICE:  NO  PACKAGING  MATERIAL  IS  LOCATED  IN  CONDENSING 

CHAMBER!  DO  NOT  REMOVE  LOWER  AIR  FLOW  GRILL  WITHOUT 
READING  AND  UNDERSTANDING  THE  PRODUCT  SAFETY,  INSTALLA-
TION AND INSTRUCTION MANUAL.

1.  Ensure that you have received pieces supplied within cooler. 

- Corresponding number of shelves standard with appliance.
- Corresponding number of shelf clips (four per shelf)

3. 

cm (1/2”) increments. 

4. 

-

 

NOTICE: RISK OF APPLIANCE DAMAGE! 

 

APPLIANCE MUST BE RUN FOR A PERIOD OF 24 HOURS PRIOR TO USE.

 

DO NOT LOAD REFRIGERATOR ABOVE LOAD LEVEL LINE INDICATOR LOCAT-
ED ON LEFT INTERIOR WALL. DO NOT LOAD PRODUCT OUTSIDE PERIMETER 
OF SHELVES. DO NOT BLOCK EXTERIOR, LOWER FRONT GRILL. FAILURE TO 
COMPLY  MAY  RESULT  IN  RESTRICTED  AIR  CIRCULATION,  SUBSTANTIALLY 
REDUCED  COOLING  PERFORMANCE,  DAMAGE  TO  REFRIGERATION  COM-
PONENTS, AND/OR FROZEN PRODUCT. 

F. THERMOSTAT (COLD CONTROL) ADJUSTMENT

All HABCO® Commercial Refrigerators are preset at the factory to main-
tain .5°C (33°F) to 3.3°C (38°F). HABCO® Commercial Refrigerators are 
equipped with a high quality thermostat (cold control) featuring an OFF 

The cold control is located on the evaporator housing (mounted to the 

should not usually require adjustment. If adjustment is required, turn 
clockwise for colder, counter-clockwise for warmer (Fig F1). 

FIG. F1

-

justment, it will take at minimum 2 hours for the cabinet temperature to 

  NOTICE:  RISK  OF  APPLIANCE  DAMAGE!  THERMOSTAT  DIAL  SETTING 

CHANGES  MAY  TURN  REFRIGERATION  SYSTEM  OFF  (90º  COUNTER-
CLOCKWISE) OR INCREASE REFRIGERATION TO FREEZING CONDITIONS 
(ANY  ADJUSTMENT  FURTHER  CLOCKWISE).  FREEZING  CONDITIONS 
CAN DAMAGE REFRIGERATION SYSTEM AND COMPONENTS, AND MAY 
CAUSE PRODUCT LOSS. CHANGES TO THE THERMOSTAT DIAL SETTING 
SHOULD  BE  MADE  BY  A  QUALIFIED  PROFESSIONAL  AFTER  DISCON-
NECTING POWER TO APPLIANCE. ISSUES ARISING FROM ALTERATIONS 
OF FACTORY PRESET POSITION ARE NOT COVERED UNDER WARRANTY.

G. LIGHTING

  WARNING: RISK OF DEATH, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR 

OTHER PERSONAL INJURY!

 

DO NOT ACCESS MECHANICALLY FASTENED AREAS WITHOUT PERMIS-
SION OF OWNER AND READING AND UNDERSTANDING THE PRODUCT 
INSTALLATION, SAFETY AND INSTALLATION MANUAL.

DISCONNECT POWER BEFORE CHANGING LAMPS OR ACCESSING ME-
CHANICALLY FASTENED AREAS.

SE40e Commercial Refrigerator light switches are located on front face 
of the interior lamp housing.

MAINTENANCE AND REPLACEMENT OF LED LIGHT STRIPS AND RELAT-

ED DRIVER COMPONENTS TO BE PERFORMED BY A QUALIFIED

TECHNICIAN ONLY.

H. DOORS

 

WARNING: RISK OF PERSONAL INJURY! EMPLOY BEST HEALTH AND SAFETY LIFT-
ING PRACTICES WHEN REMOVING SHIPPING PLATFORM(S); LEVELING CABINET; 
REMOVING DOORS; AND MOVING APPLIANCE. IF IN DOUBT, ASK FOR HELP.

  NOTICE: DOOR ADJUSTMENTS ARE NOT COVERED UNDER WARRANTY. 

INSPECT DOOR HARDWARE FOR WEAR WHEN REMOVING FOR CLEAN-
ING OR SERVICE.

-

tenance and door roller skew adjustment. Periodically, door skew may 

Sliding Door Removal:

1.  Looking up under the upper rail cover where the two sliding doors 

meet in the center, make note of how the “V” shaped door track 
sealer  strip  (Fig  H1i),  freely  rests  atop  inner  (Fig  H1ii)  and  outer 
door  frame  (Fig  H1iii)  edges  to  create  a  seal.  Ensure  that  sealer 
strip  does  not
door frame (Fig H2).

Summary of Contents for SE40e

Page 1: ...SAFETY INSTALLATION AND INSTRUCTION MANUAL Made In Canada 501 Gordon Baker Road Toronto Ontario Canada M2H 2S6 Tel 416 491 6008 Fax 416 491 6982 Toll Free in Canada 1 800 387 5398 Toll Free in U S A 1 800 448 0244 www habcotech com ...

Page 2: ...9 ENERGY EFFICIENCY TIPS HABCO Commercial Refrigerators bearing the ENERGY STAR logo are manufactured and designed to perform within the most stringent energy efficiency guidelines The following energy e ps how ever pertain to all commercial refrigerators and should be followed for best energy efficiency results 1 Maintain a clean condenser coil 2 Turn off ligh 3 Maintain clean door seals and ensure bo...

Page 3: ...VES DO NOT BLOCK EXTERIOR LOWER FRONT GRILL FAILURE TO COMPLY MAY RESULT IN RESTRICTED AIR CIRCULATION SUBSTANTIALLY REDUCED COOLING PERFORMANCE DAMAGE TO REFRIGERATION COMPONENTS AND OR FROZEN PRODUCT DO NOT LOCATE APPLIANCE IN DIRECT SUNLIGHT OR IN CLOSE PROXIMITY TO HIGH HEAT SUCH AS FRYERS RANGES AND OR HEATING DUCTS USE ONLY MILD ANTI BACTERIAL NON ABRASIVE DISH SOAP DETERGENT AND SOFT CLOTH ...

Page 4: ...RATOR INTO POSITION ENSURE THE FRONT CASTERS EXTEND OUT WARD FROM THE CABINET FACE iii When in place engage brakes on front casters C LOCATION 1 otherwise door s may not close and condensate may not drain property 2 Allow minimum 5 08 cm 2 clearance at rear of Refrigerator for WARNING RISK OF FIRE AND ELECTROCUTION DO NOT ALTER IMPACT OR PLACE PRESSURE ON POWER CORD AL LOW ADEQUATE SPACE FOR POWER...

Page 5: ... colder counter clockwise for warmer Fig F1 FIG F1 justment it will take at minimum 2 hours for the cabinet temperature to NOTICE RISK OF APPLIANCE DAMAGE THERMOSTAT DIAL SETTING CHANGES MAY TURN REFRIGERATION SYSTEM OFF 90º COUNTER CLOCKWISE OR INCREASE REFRIGERATION TO FREEZING CONDITIONS ANY ADJUSTMENT FURTHER CLOCKWISE FREEZING CONDITIONS CAN DAMAGE REFRIGERATION SYSTEM AND COMPONENTS AND MAY ...

Page 6: ...onal Patents Page 6 FIG H1 i ii iii CORRECT INCORRECT FIG H2 2 moval slot as this is where you will index the door roller Fig H3 DOOR REMOVAL SLOT S FIG H3 3 ing Fig H4 FIG H4 C 4 5 front wall 6 wall Right hand door closure spring must be installed on the right hook of the FIG H5 1 Review door removal steps 2 3 4 Ensure that both rollers are seated into the door track at top and ...

Page 7: ...ONNECT POWER BEFORE ACCESSING MECHANICALLY FASTENED AREAS WARNING RISK OF PERSONAL INJURY EMPLOY BEST HEALTH AND SAFETY LIFTING PRACTICES WHEN REMOV ING SHIPPING PLATFORM S LEVELING CABINET REVERSING DOORS AND MOVING APPLIANCE IF IN DOUBT ASK FOR HELP EMPLOY BEST HEALTH AND SAFETY PERSONAL PROTECTION PRACTICES AND ADHERE TO MANUFACTURER S WARNINGS WHEN USING TOOLS AND CLEANING AGENTS USE CARE WHEN...

Page 8: ...E RE FASTEN SECURELY i Condenser Coil Cleaning Commercial Refrigerators require the grill to be removed for condenser heat exchange coil cleaning of the condenser coil heat exchange coil located behind the lower grill on Commercial Refrigerators Visually inspect the condenser cleaning should be completed on a monthly basis Use either a nozzle for SE40ePlus Fig H8 to remove dust from between con ii...

Page 9: ...PLIANCE DAMAGE DO NOT STORE OUTDOORS IN DI RECT SUN DAMP EXTREME HEAT AND OR COLD CONDITIONS Disconnect power to refrigerator Clean thoroughly following erator with appropriate breathable cover K TROUBLE SHOOTING Prior to calling for service check the following Is the appliance plugged into dedicated grounded 3 prong wall receptacle Is the circuit breaker thrown or fuse blown Is there adequate pow...