1. Check that the power supply conforms to the data plate located on
the upper right interior wall of the cabinet.
E. START-UP
NOTICE: NO PACKAGING MATERIAL IS LOCATED IN CONDENSING
CHAMBER! DO NOT REMOVE LOWER AIR FLOW GRILL WITHOUT
READING AND UNDERSTANDING THE PRODUCT SAFETY, INSTALLA-
TION AND INSTRUCTION MANUAL.
1. Ensure that you have received pieces supplied within cooler.
- Corresponding number of shelves standard with appliance.
- Corresponding number of shelf clips (four per shelf)
3.
cm (1/2”) increments.
4.
-
NOTICE: RISK OF APPLIANCE DAMAGE!
APPLIANCE MUST BE RUN FOR A PERIOD OF 24 HOURS PRIOR TO USE.
DO NOT LOAD REFRIGERATOR ABOVE LOAD LEVEL LINE INDICATOR LOCAT-
ED ON LEFT INTERIOR WALL. DO NOT LOAD PRODUCT OUTSIDE PERIMETER
OF SHELVES. DO NOT BLOCK EXTERIOR, LOWER FRONT GRILL. FAILURE TO
COMPLY MAY RESULT IN RESTRICTED AIR CIRCULATION, SUBSTANTIALLY
REDUCED COOLING PERFORMANCE, DAMAGE TO REFRIGERATION COM-
PONENTS, AND/OR FROZEN PRODUCT.
F. THERMOSTAT (COLD CONTROL) ADJUSTMENT
All HABCO® Commercial Refrigerators are preset at the factory to main-
tain .5°C (33°F) to 3.3°C (38°F). HABCO® Commercial Refrigerators are
equipped with a high quality thermostat (cold control) featuring an OFF
The cold control is located on the evaporator housing (mounted to the
should not usually require adjustment. If adjustment is required, turn
clockwise for colder, counter-clockwise for warmer (Fig F1).
FIG. F1
-
justment, it will take at minimum 2 hours for the cabinet temperature to
NOTICE: RISK OF APPLIANCE DAMAGE! THERMOSTAT DIAL SETTING
CHANGES MAY TURN REFRIGERATION SYSTEM OFF (90º COUNTER-
CLOCKWISE) OR INCREASE REFRIGERATION TO FREEZING CONDITIONS
(ANY ADJUSTMENT FURTHER CLOCKWISE). FREEZING CONDITIONS
CAN DAMAGE REFRIGERATION SYSTEM AND COMPONENTS, AND MAY
CAUSE PRODUCT LOSS. CHANGES TO THE THERMOSTAT DIAL SETTING
SHOULD BE MADE BY A QUALIFIED PROFESSIONAL AFTER DISCON-
NECTING POWER TO APPLIANCE. ISSUES ARISING FROM ALTERATIONS
OF FACTORY PRESET POSITION ARE NOT COVERED UNDER WARRANTY.
G. LIGHTING
WARNING: RISK OF DEATH, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR
OTHER PERSONAL INJURY!
DO NOT ACCESS MECHANICALLY FASTENED AREAS WITHOUT PERMIS-
SION OF OWNER AND READING AND UNDERSTANDING THE PRODUCT
INSTALLATION, SAFETY AND INSTALLATION MANUAL.
DISCONNECT POWER BEFORE CHANGING LAMPS OR ACCESSING ME-
CHANICALLY FASTENED AREAS.
SE40e Commercial Refrigerator light switches are located on front face
of the interior lamp housing.
MAINTENANCE AND REPLACEMENT OF LED LIGHT STRIPS AND RELAT-
ED DRIVER COMPONENTS TO BE PERFORMED BY A QUALIFIED
TECHNICIAN ONLY.
H. DOORS
WARNING: RISK OF PERSONAL INJURY! EMPLOY BEST HEALTH AND SAFETY LIFT-
ING PRACTICES WHEN REMOVING SHIPPING PLATFORM(S); LEVELING CABINET;
REMOVING DOORS; AND MOVING APPLIANCE. IF IN DOUBT, ASK FOR HELP.
NOTICE: DOOR ADJUSTMENTS ARE NOT COVERED UNDER WARRANTY.
INSPECT DOOR HARDWARE FOR WEAR WHEN REMOVING FOR CLEAN-
ING OR SERVICE.
-
tenance and door roller skew adjustment. Periodically, door skew may
Sliding Door Removal:
1. Looking up under the upper rail cover where the two sliding doors
meet in the center, make note of how the “V” shaped door track
sealer strip (Fig H1i), freely rests atop inner (Fig H1ii) and outer
door frame (Fig H1iii) edges to create a seal. Ensure that sealer
strip does not
door frame (Fig H2).