background image

HABCO® TECHNICAL DOCUMENT - C097584   •   10125169

© HABCO Manufacturing Inc. “HABCO®, Cassette®, Cold Space Merchandiser®” are registered trademarks of HABCO Manufacturing Inc. Domestic and International Patents. Page 2

HABCO® COMMERCIAL REFRIGERATORS
SAFETY, INSTALLATION AND INSTRUCTION MANUAL

MODELS: SE40e

IMPROPER OR UNSAFE 

use of this appliance other than intended by 

the manufacturer, can result in death, serious bodily injury, property 
damage and/or appliance damage!

Please keep this manual available for other users and owners before 

 WARNING

INTENDED USE

HABCO®  Commercial  Refrigerators  are  designed  for  the  commercial 

-
-

tended for use in outdoor, direct sun, damp, extreme heat and/or cold 

MEANINGS OF SIGNAL WORDS AND SYMBOLS

 

WARNING

if ignored, could result in death or serious injury.

 

WARNING

if not avoided, may result in minor or moderate injury.

 

NOTICE

cause appliance damage or environmental harm.

Table of Contents

 

Subject 

 

 

 

           Page

 

INFORMATION AND TABLE OF CONTENTS ......................2 
SAFETY .............................................................................3

A. 

INSPECTION & UNPACKING  ............................................4

B. 

CASTER KIT INSTALLATION (Op

 ..............................4

C. 

LOCATION ........................................................................4

D. 

ELECTRICAL ......................................................................4

E. 

START-UP .........................................................................5

F. 

THERMOSTAT LOCATION & ADJUSTMENT .......................5

G. 

LIGHTING .........................................................................5

H. 

DOORS .............................................................................5

 

Sliding Door Removal ......................................................5

 

Correct Door Closure Spring Orienta

 ........................6

 

Sliding Door Reinstalla

 ..............................................6

 

Sliding Door Skew Adjustment ........................................7

I. 

SPECIFIC PREVENTATIVE MAINTENANCE .........................7
Free’n’Clear™ Condenser Coil (SE40e) ............................7
Comba

rs .........................................................8

J. 

GENERAL CLEANING PROCEDURES .................................8

K. 

TROUBLE-SHOOTING .......................................................9

ENERGY EFFICIENCY TIPS 

 

          

HABCO® Commercial Refrigerators bearing the ENERGY STAR® logo 
are manufactured and designed to perform within the most stringent 
energy efficiency guidelines. The following energy e

ps, how-

ever, pertain to all commercial refrigerators and should be followed for 
best energy efficiency results.

1. 

Maintain a clean condenser coil.

2. 

Turn off ligh

3. 

Maintain clean door seals and ensure bo om door guide is 
clear of debris a

4. 

Maintain minimum 2” rear spacing behind appliance for 
adequate air-flow and heat exhange.

5. 

Do not install in direct vicinity of high heat sources such as 
ranges, and ovens.

6. 

Do not install directly beneath undiffused air c
vents.

7. 

Read, understand and observe Safety W
in this manual as many of these points will also contribute 
to energy savings and appliance efficiency.

Glossary

Term 

Explana

Commercial Refrigerator 

 

     

 

Appliance

Free’n’Clear™ Condenser (Coil) 

 

               

 

         Circular Formed Heat Exchange Coil Mounted in Base of Cabinet 

Lint-Tolerant Condenser (Coil) 

    

 

          Heat-Exchange Coil Mounted at Front Base of Cabinet

Evaporator (Coil)         

 

               Cooling Coil to Ceiling of Cabinet Interior

Compressor 

         

    

 

        Refrigerant Compressing Motor Mounted in Base of Refrigerator

Condensing Chamber 

    

 

              Compressor and Condenser Coil Enclosure at Base of Cabinet

Evaporator Housing  

 

 

               Cooling Coil Enclosure Surrounding Evaporator Coil, Mounted to Ceiling of Cabinet Interior

Mechanically Fastened Areas        

 

             Areas Requiring a Tool to Access

Trained Professional 

     

 

          

Owner         

 

             Person or Company Holding Legal Title to Appliance

Roller Panel Cover       

 

              Upper Front Metal Panel Covering Top Mounted Door Rollers

Summary of Contents for SE40e

Page 1: ...SAFETY INSTALLATION AND INSTRUCTION MANUAL Made In Canada 501 Gordon Baker Road Toronto Ontario Canada M2H 2S6 Tel 416 491 6008 Fax 416 491 6982 Toll Free in Canada 1 800 387 5398 Toll Free in U S A 1 800 448 0244 www habcotech com ...

Page 2: ...9 ENERGY EFFICIENCY TIPS HABCO Commercial Refrigerators bearing the ENERGY STAR logo are manufactured and designed to perform within the most stringent energy efficiency guidelines The following energy e ps how ever pertain to all commercial refrigerators and should be followed for best energy efficiency results 1 Maintain a clean condenser coil 2 Turn off ligh 3 Maintain clean door seals and ensure bo...

Page 3: ...VES DO NOT BLOCK EXTERIOR LOWER FRONT GRILL FAILURE TO COMPLY MAY RESULT IN RESTRICTED AIR CIRCULATION SUBSTANTIALLY REDUCED COOLING PERFORMANCE DAMAGE TO REFRIGERATION COMPONENTS AND OR FROZEN PRODUCT DO NOT LOCATE APPLIANCE IN DIRECT SUNLIGHT OR IN CLOSE PROXIMITY TO HIGH HEAT SUCH AS FRYERS RANGES AND OR HEATING DUCTS USE ONLY MILD ANTI BACTERIAL NON ABRASIVE DISH SOAP DETERGENT AND SOFT CLOTH ...

Page 4: ...RATOR INTO POSITION ENSURE THE FRONT CASTERS EXTEND OUT WARD FROM THE CABINET FACE iii When in place engage brakes on front casters C LOCATION 1 otherwise door s may not close and condensate may not drain property 2 Allow minimum 5 08 cm 2 clearance at rear of Refrigerator for WARNING RISK OF FIRE AND ELECTROCUTION DO NOT ALTER IMPACT OR PLACE PRESSURE ON POWER CORD AL LOW ADEQUATE SPACE FOR POWER...

Page 5: ... colder counter clockwise for warmer Fig F1 FIG F1 justment it will take at minimum 2 hours for the cabinet temperature to NOTICE RISK OF APPLIANCE DAMAGE THERMOSTAT DIAL SETTING CHANGES MAY TURN REFRIGERATION SYSTEM OFF 90º COUNTER CLOCKWISE OR INCREASE REFRIGERATION TO FREEZING CONDITIONS ANY ADJUSTMENT FURTHER CLOCKWISE FREEZING CONDITIONS CAN DAMAGE REFRIGERATION SYSTEM AND COMPONENTS AND MAY ...

Page 6: ...onal Patents Page 6 FIG H1 i ii iii CORRECT INCORRECT FIG H2 2 moval slot as this is where you will index the door roller Fig H3 DOOR REMOVAL SLOT S FIG H3 3 ing Fig H4 FIG H4 C 4 5 front wall 6 wall Right hand door closure spring must be installed on the right hook of the FIG H5 1 Review door removal steps 2 3 4 Ensure that both rollers are seated into the door track at top and ...

Page 7: ...ONNECT POWER BEFORE ACCESSING MECHANICALLY FASTENED AREAS WARNING RISK OF PERSONAL INJURY EMPLOY BEST HEALTH AND SAFETY LIFTING PRACTICES WHEN REMOV ING SHIPPING PLATFORM S LEVELING CABINET REVERSING DOORS AND MOVING APPLIANCE IF IN DOUBT ASK FOR HELP EMPLOY BEST HEALTH AND SAFETY PERSONAL PROTECTION PRACTICES AND ADHERE TO MANUFACTURER S WARNINGS WHEN USING TOOLS AND CLEANING AGENTS USE CARE WHEN...

Page 8: ...E RE FASTEN SECURELY i Condenser Coil Cleaning Commercial Refrigerators require the grill to be removed for condenser heat exchange coil cleaning of the condenser coil heat exchange coil located behind the lower grill on Commercial Refrigerators Visually inspect the condenser cleaning should be completed on a monthly basis Use either a nozzle for SE40ePlus Fig H8 to remove dust from between con ii...

Page 9: ...PLIANCE DAMAGE DO NOT STORE OUTDOORS IN DI RECT SUN DAMP EXTREME HEAT AND OR COLD CONDITIONS Disconnect power to refrigerator Clean thoroughly following erator with appropriate breathable cover K TROUBLE SHOOTING Prior to calling for service check the following Is the appliance plugged into dedicated grounded 3 prong wall receptacle Is the circuit breaker thrown or fuse blown Is there adequate pow...

Reviews: