3. Cleaning work

WARNING

Before starting any cleaning work, the stove must be cool down!
Once the cleaning work is completed, the correct operating status of the device must be re-
established: Put the combustion pot in correctly, close the combustion chamber door.

3.1. Cleaning the surface

Dirt on the upper surface of the stove may be cleaned off with a damp cloth or if necessary with mild soapy
water. You are advised against using corrosive cleaning agents and solvents since these might damage the
surfaces.

3.2. Cleaning the glass panel

To clean the viewing panel, you must first open the stove door. Dirt on the glass panel can be removed with a
glass cleaner or with a damp sponge on which you have sprinkled some of the wood ash present.
(Environmentally friendly). Cleaning the glass panel may only be done with a cooled down stove in the OFF
operating mode.

3.3. Clean combustion chamber “function instruction” Error
F040

• The whole combustion space must be cleaned after

50-hours operation at the latest, or once a week

.

• The requirement to clean the fire-box (flickering of the display) appears during heating, in case that the

cleaning interval has elapsed.

• After the fire-box has been cleaned, the error message "Clean the fire-box" will be confirmed automatically.

The condition for automatic confirmation of this error message is that the fire-box door is opened for more
than

60 seconds

. This time is necessary for careful cleaning of the fore-box, including the burner.

• This reset of the operating hours counter occurs even if the cleaning of the combustion chamber is

performed before the 30 operating hours have run provided that the stove is in “Off” operating status and the
door is open for longer than 60 seconds during cleaning.

3.4. Cleaning the combustion pot - weekly

During operation, deposits may form in the combustion pot. How quickly the combustion pot becomes dirty
depends solely on fuel quality. The deposits or encrustations must be removed from time to time.

WARNING

If this is not done, the clinker will continue to accumulate. Then the device will no longer be able to ignite
properly. Pellets can pile up in the combustion pot. In extreme cases, this can reach all the way back to the
pellet chute. Backfire in the pellet container and smouldering in the pellet tank might possibly result.

This will destroy your device and is not covered in your guarantee.

Summary of Contents for HSP 4.0-F2

Page 1: ...HSP 4 0 F2 Equipment sheet Pellet stove GB 0545608001403 Equipment sheet HSP 4 0 F2...

Page 2: ...he heating device or of an injury The note entitled Notice advises you on possible damage to your heating device The note entitled Important calls your attention to the information important for the o...

Page 3: ...or F040 4 3 4 Cleaning the combustion pot weekly 4 4 Maintenance work 7 4 1 Cleaning of the ash pan once a week 7 4 2 Cleaning the flue gas passes 8 4 2 1 Cleaning the flue baffle 9 4 3 Cleaning the p...

Page 4: ......

Page 5: ...n of dust in flue gas 5 mg Nm 10 mg Nm 19 mg Nm Contents of storage container pellet tank about 40 kg Duration of burn with one charge min max about 21 h about 44 h about 44 h Permitted fuel Low dust...

Page 6: ...Dimensions GB 2 2 Dimensions 2 1 Flue pipe conn on the top Pos 1 for external air input Pos 2 convection air for 2nd room...

Page 7: ...Dimensions GB 3 2 2 Flue pipe conn rear Pos 1 for external air input Pos 2 convection air for 2nd room...

Page 8: ...e display appears during heating in case that the cleaning interval has elapsed After the fire box has been cleaned the error message Clean the fire box will be confirmed automatically The condition f...

Page 9: ...only be done with a cooled down stove in OFF operating mode Otherwise there is a risk of burns Clean the burner with the supplied tool By scraping the burner wall dirt falls down through the cleaning...

Page 10: ...Cleaning work GB 6 Figure 1 Cleaning the combustion pot using the supplied tool...

Page 11: ...pellet quality ash content Quality pellets have a low ash content of about 0 2 0 3 However if the ash content is higher 0 5 and over the interval from maintenance to maintenance is reduced and the ac...

Page 12: ...nd flue gas ducts at the latest after 1000 kg of pellets have been consumed Clean with a brush or an ash extractor CAUTION After completion of the cleaning make sure that when putting back the covers...

Page 13: ...g 1000 kg of pellets or after a year of operation it is necessary to clean the deflector using the enclosed tool CAUTION To remove the deflector you must retract the flame temperature sensor otherwise...

Page 14: ...1 in the pellet tank may be removed Then clean the tank and the intake of the screw conveyor housing with a vacuum cleaner After cleaning it is essential to put back the protective grille When doing...

Page 15: ...parts list 5 1 Replacement parts list without trim parts Pos Description Piece No PR Replacement parts list without trim parts A1 Complete combustion chamber door anthracite 1 piece 0545508005300 1 As...

Page 16: ...er screw conveyor bearing 1 piece 0571207005027 16 Screw conveyor 1 piece 0545608015030 17 Conveyor 1 piece 0545608015060 18 Collet 1 piece 0545508015125 19 Motor plate 1 1 piece 0545508015042 20 Moto...

Page 17: ...08006130 5 2 Detail A1 Pos Description Piece No PR Detail A1 A1 1 Screwing door Set 1 piece 0545508005301 A1 2 Glass holder anthracite Set 1 piece 0545508005302 38 Seal door 16 mm 1500 mm 1 piece 0040...

Page 18: ...t 41 Side wall right black glossy 1 piece 0545608005130 41 Side wall right grey 1 piece 0545608015130 41 Side wall right white 1 piece 0545608025130 42a Front plate right black glossy 1 piece 05456080...

Page 19: ...545608025160 43 Front plate left black glossy 1 piece 0545608005110 43 Front plate left grey 1 piece 0545608015110 43 Front plate left white 1 piece 0545608025110 44 Side wall left black glossy 1 piec...

Page 20: ...Wei Rot Wei Wei Braun Differenzdruck Schwarz Blau Anschlussplan IO57 1 Braun Netz 230V Gelb Gr n Blau Schwarz Z ndung 230V Schwarz A1 Schwarz Relais Schnecke A2 Braun Schwarz STB Gelb Gr n Schwarz Re...

Page 21: ...w conveyor motor relay 7 Induced draught 8 Cleaning roller 9 Conv fan 11 Screw conveyor motor relay 12 14 Flue gas fan rotation speed 22 23 Tank cover 26 27 Door contact switch 30 31 Flue gas temperat...

Page 22: ...am relay Anschlussplan Relais Schnecke Rot Grau Blau Braun Schwarz Steuer platine Schnecke Steuer platine Steuer platine Description Circuit diagram No Description Cable harness A1 A2 Control board 11...

Page 23: ......

Page 24: ...Installation and operating manual Pellet stove Installation and operating manual Pellet stove GB 0545508001413 Pellet stove Nameplate...

Page 25: ...ent sheet is part of these operating instructions Notes in the text Of utmost importance there are the notes entitled WARNING The notes entitled WARNING advise you on serious danger of damage to the h...

Page 26: ...lay 9 7 Operating the pellet stov 9 7 1 Suitable fuels 9 7 2 Unsuitable fuels 9 7 3 Using for the first time 9 7 3 1 General 9 7 3 2 Operating console 10 8 Additional operator console functions 12 8 1...

Page 27: ...de 23 11 7 Standby 24 11 8 Shut down 24 11 9 Cooling 24 11 10 Error display Fault 24 11 11 OFF 24 12 Overheating protection 24 13 Power cut 24 14 Cleaning and maintenance work see Appliance sheet 3 4...

Page 28: ...combustion air opening provided must not be closed throttled constricted covered or shut off On stoves with an outdoor air connection the opening must not be shut or closed during operation This appl...

Page 29: ...of in accordance with the local laws of the specific country This applies to products put into service after August 13 2005 in Germany after March 23 2006 3 Electrical connection The stove is operated...

Page 30: ...he chimney gas tight flue tubes should be used Approved flex steel tubes are also suitable Please observe the national regulations The flue tube must be securely fitted on the flue gas spigot The flue...

Page 31: ...tive length of the chimney C Inlet of outside air D T shaped block with plug for discharge of condensate 5 Installation CAUTION For comfortable maintenance and service are following distances recommen...

Page 32: ...the sides and in the direction of radiation forwards must be maintained according to the nameplate WARNING Floor protection In case of flammable or temperature sensitive floor coverings the appliance...

Page 33: ...t draw air from the room where it is installed This allows the stove to be operated in low energy or passive houses or in houses equipped with mechanical ventilation systems 5 4 Outside air connection...

Page 34: ...must be supplied from the outside or from an approved chimney system e g LAS system 5 5 Convection air distribution Double Air only for stoves with a convection blower Depending on the specific varian...

Page 35: ...etent person 5 6 Room temperature sensor Note A room temperature sensor is installed on the back of the stove In the box there is about 0 8 m long cable so the sensor can be placed farther away from t...

Page 36: ...fuels The use of lower quality or unauthorised fuel adversely affects the operation of your pellet stove and may lead to the lapse of the guarantee Burning wood pellets of a poor quality leads to clea...

Page 37: ...F2 when using for the first time the Manual filling process must be started twice see point 9 1 12 Due to the different expansion of the materials used the stove may make sounds resembling ticking or...

Page 38: ...Plus or Minus buttons The setting is saved by pressing the OK button 18 10 30 OK 7 3 2 4 Starting the pellet stove operating mode ON Procedure On the standard screen press the ON OFF button to get th...

Page 39: ...is adequate ventilation in the installation room during this time and avoid inhaling directly The varnish is prone to scratches and damage before commissioning but hardens after repeated heating Note...

Page 40: ...tton lock child safety device Procedure Activation Hold the Menu button down for approx 10 seconds until Button block activated appears on the display Deactivation Hold the Menu button down for approx...

Page 41: ...Log Manual filling for HSP 4 0 F2 only Info Software Language 9 1 1 Manual operating mode Oper mode Procedure Press the Manually function to activate the manual operating mode Manually off Automatic 2...

Page 42: ...de Weekly program Oper mode Procedure Press the Weekly program function to activate this operating mode Manually off Automatic 20 C Weekly program off Weekly program Procedure After selecting the day...

Page 43: ...e to start the stove early by pressing the ON OFF button The next heating zone is selected directly for this 09 33 STANDBY STANDBY Next heating zone Wed 14 00 18 00 22 C Weekly program Stove Early sta...

Page 44: ...e Procedure To activate ECO Mode resize the button Oper mode Automatic Heating curve 2 ECO Mode Maintenance 1000 kg 9 1 6 Maintenance Maintenance The service interval can only be reset after burning m...

Page 45: ...he date and time Confirm the selection by pressing the OK button Day Do 03 Month 09 Year 2020 Time 07 29 OK 9 1 9 Display Display In the Display menu you can set the brightness screen saver displays t...

Page 46: ...name HaasSohn_ WIFI password 9 1 10 3 Network name Network The name of the local WLAN network is displayed in the Network name line Mode local HaasSohn App PIN 4363 Network name HaasSohn_ WIFI passwo...

Page 47: ...y Network Error Log Info Software 9 1 12 Manual filling for HSP 4 0 F2 only Manual filling Procedure In the main menu select the Manual filling function and press the START button The fuel conveyor is...

Page 48: ...tton Info Software Language Deutsch 10 Mobile application general safety instructions The application may only be operated by persons who have become familiar with the safety regulations for H S stove...

Page 49: ...Network modes Modes local HaasSohn local global If your own WLAN Wifi network is not available this setting can be used to set up a new Haas Sohn network Hotspot without internet connection only for...

Page 50: ...reset levels The higher the level 1 5 the higher the heat output Automatic control The heat output is controlled according to the difference between the set and Actual room temperature 11 4 Burner tes...

Page 51: ...ger be automatically started up The operator can see the fault on the display Once the fault has been properly corrected and the error message on the operator console has been cleared the stove can be...

Page 52: ...t service department B Fuse F1 3 15 A defective contact service department C Ignition defective contact service department F0002 A Burner dirty B Pellet tank empty C Ignition defective D Burner not ly...

Page 53: ...service department F0015 A Induced draught fan defective B Power supply to the fan motor interrupted A Contact service department B Check cable contact service department F0018 A Power cut A Clean bu...

Page 54: ...chamber dirty B Flame temperature sensor at bottom defective A Clean burner B Contact service department F0033 A No WLAN connection B WLAN code is incorrect C No IP address received A Check WLAN recep...

Page 55: ...ow noise levels may occur These sounds are due to factors that are out of control and therefore should not be considered a reason for claims 17 Warranty HAAS SOHN gives the purchaser a warranty within...

Page 56: ...partner where you purchased the appliance Note So that your enquiry can be dealt with quickly the following details from the nameplate are essential Exact type designation version of the model Manufac...

Page 57: ......

Page 58: ......

Page 59: ...All documents such as operating instructions appliance sheet test reports etc and contact details can also be found under www haassohn com...

Reviews: