background image

Replacement

parts

list

GB

11

34

Screw conveyor

1 piece

0571207005030

35

Lower screw conveyor bearing

1 piece

0571207005026

36

Collet

1 piece

0089000340005

37

Screw UN5950 M5x10

4 piece

-

38

Air hose

1 piece

0551908015315

5.2. Detail A1

Pos.

Description

Piece

No. PR

Detail A1

A1.1.

Screwing door - Set

1 piece

0551908005001

A1.2.

Door hinge - Set

1 piece

0551908005002

A1.3.

Glass holder - Set

1 piece

0551908005003

39

Combustion chamber door/black

1 piece

0551908007201

40

Seal glass 10x4 mm (900 mm)

1 piece

0040210040005

Summary of Contents for 0543408100000

Page 1: ...HSP 6 Pallazza III 520 08 RLU PGI Equipment sheet Pellet stove GB 0552008001403a Equipment sheet HSP 6 Pallazza III 520 08 RLU PGI ...

Page 2: ...the heating device or of an injury The note entitled Notice advises you on possible damage to your heating device The note entitled Important calls your attention to the information important for the operation of your heating device The note itself calls your attention to the information important for the operation of your heating device in general ...

Page 3: ...struction Error F040 3 3 4 Cleaning the combustion pot weekly 3 4 Maintenance work 5 4 1 Cleaning the flue gas passes 5 4 2 Cleaning the pellet container annual maintenance 8 5 Replacement parts list 9 5 1 Replacement parts list Pallazza III 520 08 RLU PGI without trim parts 9 5 2 Detail A1 11 5 3 Replacement parts list Pallazza III 520 08 RLU PGI 12 6 Circuit diagram 13 ...

Page 4: ......

Page 5: ...ontents of storage container pellet tank about 17 kg Duration of burn with one charge min max about 10 h 30 h Permitted fuel Low dust wood pellets Diameter 6 mm to Ö Norm M 7135 DIN plus EN plus A1 Length max 30 mm Room heating capacity to Ö Norm M 7521 max 230 m Room heating capacity to DIN 18893 constant heating 250m 145m 98m Room heating capacity to DIN 18893 timed heating 165m 95m 65m Electric...

Page 6: ...Dimensions GB 2 2 Dimensions ...

Page 7: ...ustion chamber function instruction Error F040 The whole combustion space must be cleaned after 30 hours operation at the latest or once a week The requirement to clean the fire box flickering of the display appears during heating in case that the cleaning interval has elapsed After the fire box has been cleaned the error message Clean the fire box will be confirmed automatically The condition for...

Page 8: ...ering in the pellet tank might possibly result This will destroy your device and is not covered in your guarantee WARNING Cleaning the combustion pot may only be done with a cooled down stove in OFF operating mode Otherwise there is a risk of burns Take out the burner bowl from the stove Remove the remains of ashes and slag After the cleaning mount the burner bowl back to its proper position on th...

Page 9: ...h content is higher 0 5 and over the interval from maintenance to maintenance is reduced and the accumulation of ash increases by 2 or 3 times WARNING Devices that are not maintained in accordance with our specifications must not be operated Failure to observe this point will invalidate all guarantee claims 4 1 Cleaning the flue gas passes CAUTION Check and clean the flue gas ways exhaust flue gas...

Page 10: ...Maintenance work GB 6 Figure 1 Removing the flue baffle ...

Page 11: ...work GB 7 Figure 2 Removing the side wall CAUTION After completion of the cleaning make sure that when putting back the covers the seals are seated in the right positions It is essential to replace defective seals ...

Page 12: ... 1 in the pellet tank may be removed Then clean the tank and the intake of the screw conveyor housing with a vacuum cleaner After cleaning it is essential to put back the protective grille When doing this make sure that no screws fall into the pellet tank so as to avoid consequential damage to the screw conveyor Figure 3 Pellet tank 1 Protective grille 2 Tank cover ...

Page 13: ...Replacement parts list GB 9 5 Replacement parts list 5 1 Replacement parts list Pallazza III 520 08 RLU PGI without trim parts ...

Page 14: ...attery CR 2032 1 piece 13 Stand 4 piece 0551908505005 14a Ignition 1 piece 0541908005202 14b Lighter case 1 piece 0553808005215 15 Room temperature sensor 1 piece 0089500390005 16 Flue gas thermosensor 1 piece 0561008005540 17 OC 1 piece 0089500080005 18 Cover hinge pins DIN 427 M5x18 1 piece 0551908005015 19 Protective grille 1 piece 0551908005931 20 Closure frame 1 piece 0551908005160 21 Framewo...

Page 15: ...5 37 Screw UN5950 M5x10 4 piece 38 Air hose 1 piece 0551908015315 5 2 Detail A1 Pos Description Piece No PR Detail A1 A1 1 Screwing door Set 1 piece 0551908005001 A1 2 Door hinge Set 1 piece 0551908005002 A1 3 Glass holder Set 1 piece 0551908005003 39 Combustion chamber door black 1 piece 0551908007201 40 Seal glass 10x4 mm 900 mm 1 piece 0040210040005 ...

Page 16: ... III 520 08 RLU PGI 43 Side wall rear right antracite 1 piece 0551908015510 44 Side wall middle right black 1 piece 0551908016400 45 Side wall front right antracite 1 piece 0551908026300 46 Front plate black anthracite 1 piece 0551908116200 47 Side wall rear left antracite 1 piece 0551908015511 48 Side wall middle left black 1 piece 0551908016410 49 Side wall front left antracite 1 piece 055190802...

Page 17: ...Circuit diagram GB 13 6 Circuit diagram Circuit diagram IO 33 3 ...

Page 18: ...conveyor motor 7 Induced draught 8 9 OC 35 36 Flue gas temperature sensor 37 38 Flame temperature sensor 39 40 Room temperature sensor 41 42 Bottom flame temperature sensor 43 44 Door contact switch 48 50 Flue gas fan rotation speed F1 Fuse T 3 15 A ignition induced draught fan screw conveyor motor F3 Fuse T 0 315 A operator console ...

Page 19: ......

Reviews: