12 Installation
Attention!
When installing the component, choose a
means of attachment that cannot easily be
detached (e.g. riveting or safety screws).
12.1 Preparation
Before beginning installation, ensure that the identification number given in this installation and opera-
tion manual corresponds to the identification number of the component.
Installing the component requires the following items that are
not
included in the scope of the delivery:
HST-TZ1 Ident.-No.: 10234 and HST-TZ1 Ident.-No.: 10235:
2
screws M8 x “length of relevant installation site“ from A2-70
2
M6 safety “length of relevant installation site” from A2-70
Screw locking devices (toothed lock washers, disc springs, shaft washers, or screw adhesive)
HST-TZ1 Ident.-No.: 10236 and HST-TZ1 Ident.-No.: 10237:
2
screws M6 x “length of relevant installation site“ from A2-70
2
M6 safety “length of relevant installation site” from A2-70
Screw locking devices (toothed lock washers, disc springs, shaft washers, or screw adhesive)
Clean the work environment by removing dirt, grease and oil.
12.2 General approach
Use suitable tools when installing the component. Otherwise, bolts and nuts may become damaged
and unusable.
When tightening the screws listed in section 12.1, do not exceed the max. tightening torque.
Use the items listed in section 12.1 to secure the screw connections.
12.3 Installation instructions
Make the mounting holes according to the design of the component. The mounting holes should be
arranged as shown in the diagrams (cf. section 20:
Dimensions
) and the drilling template.
The casing with a Blocking mechanism and integrated lock is to be attached on the stable part of the
separating safeguard (for example on the frames of the protective door or flap).
The Actuator is to be attached to the moving part of the separating safeguard.
Care must be taken that the casing with the Blocking mechanism and lock are not used as a stop for
the moving part of the separating safeguard
No liability is accepted in the event of improper installation!